Options / Accessories

for Environmental test chambers

Memmert environmental test chambers guarantee the perfect atmosphere for climate and temperature tests

Option

Model sizes 256
Full-sight glass door (5-layer insulating glazing), heated B0
Entry port, left, 80 mm, with stopper F0
Works calibration certificate for one temperature according to customer specification (only TTC) D00109
Works calibration certificate for one temperature and humidity according to customer specification (only CTC) D00105
Door-hinges on left side B8
Potential-free contact (24 V/2 A) with socket, according to NAMUR NE 28 for combination error message (e.g. supply failure, sensor fault, fuse); VO only in combination with option T5 Potential-free contact (24 V/2 A) with socket, according to NAMUR NE 28 for combination error message (e.g. supply failure, sensor fault, fuse); VO only in combination with option T5 H6
Interface Ethernet instead of USB including software W4
RS232 interface instead of USB W6
MobileALERT, notification by SMS in case of any error or alarm of the device. Requires option H6 “floating contact for alarm” C3

Accessory

Model sizes 256
Additional stainless steel grid Additional stainless steel grid E20591
Stainless steel slide-in drip tray, 15 mm rim (may affect the temperature distribution) Stainless steel slide-in drip tray, 15 mm rim (may affect the temperature distribution)
External control and logging package consisting of mini-Notebook and software „Celsius“, pre-configurated, and lateral swinging arm B04410
USB connection cable for computer interface E03643
Temperature profile write/read unit for programming via PC, for writing to and reading from the chip card, up to 40 ramps E05284
Additional chip card, blank, formatted (32 kB MEMoryCard XL for a maximum of 40 ramps) E04004
Oven-linked authorisation card (User-ID-Card) prevents undesired manipulation by unauthorised third parties. When reordering please specify serial number E04159
Software conforming to FDA ”Celsius FDA Edition“ for up to 16 units. Meets the requirements for the use of electronically stored data sets and electronic signatures as laid down in Regulation 21 CFR Part 11 of the US Food and Drug Administration (FDA). Not applicable for UFP800DW E05019
Integration of additional units (up to max.16 units) into an already existent FDA-software licence. Not applicable for UFP800DW FDAQ4
IQ check list with works test data for chamber as support for validation by customer D00103
OQ check list with device-specific works test data for one free-selectable temperature value, incl. temperature distribution survey at Memmert for 27 measuring points to DIN 12880:2007-05 as support for validation by customer D00104
OQ check list with works test data for one free-selectable temperature value incl. temperature distribution survey for 27 measuring points to DIN 12880:2007-05 as support for validation by customer (only CTC) D00144
External measuring instrument with sensors for daylight and UV-light, with additional measuring head for temperature and humidity. Product information on demand (models HCP and CTC) B04714
DAkkS calibration for one (freely selectable) temperature and humidity value according to method C (DKD-R 5-7) (only CTC) E48847
DAkkS calibration for further temperature and humidity values according to method C (DKD-R 5-7) (only CTC) E48848
DAkkS calibration for one free-selectable temperature value according to method C (DKD-R 5-7) E39696
DAkkS calibration for further temperature values according to method C (DKD-R 5-7) E39697
On-site IQ/OQ for a freely selectable temperature value, including temperature distribution survey for 27 measuring points to DIN 12880: 2007-05 (excluding travel costs, not subject to discount, GER, AT, FR only) (only TTC) DLQ100
Extension of DLQ100 by an additional freely selectable temperature value (not subject to discount) (only TTC) DLQ100A
On-site IQ/OQ for a freely selectable temperature and humidity value, including temperature distribution survey for 27 measuring points to DIN 12880: 2007-05 (excluding travel costs, not subject to discount, GER, AT, FR only) (only CTC) DLQ101
Extension of DLQ101 by an additional freely selectable temperature and humidity value (not subject to discount) (only CTC) DLQ101A
Individual on-site Performance Qualification (PQ) DLQ200
Maintenance "Basic" - carrying out and documentation according to Memmert maintenance plan (excluding travel costs, not subject to discount, GER, AT, FR only) S00400
Maintenance "Medium" - carrying out and documentation according to Memmert maintenance plan (excluding travel costs, not subject to discount, GER, AT, FR only) S00401
Maintenance "Premium" - carrying out and documentation according to Memmert maintenance plan (excluding travel costs, not subject to discount, GER, AT, FR only) S00402
Calibration of one freely selectable temperature value (excluding travel costs, not subject to discount, GER, AT, CH, FR only) S00205
Calibration of an additional temperature value (not subject to discount) S00215
Calibration of one freely selectable temperature and humidity value (excluding travel costs, not subject to discount, GER, AT, CH, FR only) (only CTC) S00207
Calibration of an additional temperature and humidity value (not subject to discount) (only CTC) S00216