Options / Accessories

for Humidity Chamber HCP240

Active humidity control creates a controlled environment for accelerated life tests and 85/85 tests.

Option

Option Order No.
Works calibration certificate for one (freely selectable) temperature and humidity value D00105
MobileALERT for up to 4 alarm notifications; standard: temperature and CO2 alarm, additionally humidity alarm (when equipped with option K7) and O2 alarm (when equipped with option T6) C4
Potential-free contact (24V/2A) with socket 3 pin,
according to NAMUR NE 28 for external monitoring
(setpoint of temperature and CO<sub>2</sub> is reached) Potential-free contact (24V/2A) with socket 3 pin, according to NAMUR NE 28 for external monitoring (setpoint of temperature and CO2 is reached) H5
Door hinged on the left B8
Potential-free contact for combination error message (e.g. supply failure, sensor fault, fuse) Potential-free contact for combination error message (e.g. supply failure, sensor fault, fuse) H6
MobileALERT, notification by SMS in case of any error or alarm of the device. Requires option H6 “floating contact for alarm” C3

Accessory

Accessory Order No.
Stacking set (consisting of stacking corners, one connecting plate for the rear, two wall brackets) for stacking two units ICO150med or ICO240med B42115
IQ/OQ document with device-specific works test data for one freeselectable CO2 and temperature value, incl. temperature distribution survey at Memmert for 27 measuring points to DIN 12880:2007-05, PQ check list as support for validation by customer (models ICOmed). D38898
IQ/OQ document with device-specific works test data for one free-selectable CO2, humidity and temperature value, incl. temperature distribution survey at Memmert for 27 measuring points to DIN 12880:2007-05, PQ check list as support for validation by customer (models ICH C and ICOmed, on models ICOmed a free-selectable humidity value is only possible with option K7). D38897
Ethernet connection cable 5 m for computer interface E06189
Central water supply with filter cartridges for connection to the domestic water supply. Product information on demand. ZWVR6
Central water supply without filter cartridges for connection to the domestic water supply (only for demineralised water in accordance with VDE 0510/DIN EN 50272). Product information on demand ZWVR7
Additional perforated stainless steel shelf E35158
Additional stainless steel grid Additional stainless steel grid E43118
USB-Ethernet adapter E06192
USB User-ID stick (with User-ID licence): Oven-linked authorisation licence (User-ID-programme) on Memory-stick, prevents undesired manipulation by unauthorised third parties. When reordering please specify serial number (only for units with TwinDISPLAY) B33170
USB stick with documentation software AtmoCONTROL and operation manual for products with SingleDISPLAY (the standard equipment of appliances with TwinDISPLAY includes one USB stick with AtmoCONTROL) B33172
Set of height adjustable feet (4 pcs). Standard on models ICOmed B29768
Software conforming to FDA “AtmoCONTROL“. Meets the requirements for the use of electronically stored data sets and electronic signatures as laid down in Regulation 21 CFR Part 11 of the US Food and Drug Administration (FDA). Base licence for the control of one unit (only for units with TwinDISPLAY). Respective IQ/OQ documents available in German and English language (without surcharge). FDAQ1
Integration of one additional unit (up to max. 15 units) into an already existent FDA-software licence FDAQ2
IQ document with device-specific works test data, OQ/PQ check list as support for validation by customer D00124