Works calibration certificate for one (freely selectable) temperature and humidity value |
D00105
|
|
Works calibration certificate for one (freely selectable) temperature, humidity, CO2 and O2 value according to customer specification (requires T6) |
D00143
|
|
Works calibration certificate for one (freely selectable) temperature, humidity and CO2 value according to customer specification (requires K7) |
D00131
|
|
Works calibration certificate for one (freely selectable) temperature and pressure value (per thermoshelf) according to customer specification |
D00116
|
|
Works calibration certificate for one (freely selectable) temperature value according to customer specification |
D00109
|
|
Temperature restriction - Temperatures: +50, +55, +60, +65, +70 or +75 °C (Please, indicate upon ordering) |
A8
|
|
Temperature restriction - Temperatures: +60, +70, +80, +95, +100, +120, +160, +180, +200 or +250 °C (Please, indicate upon ordering) |
A8
|
|
Flexible Pt100 temperature sensor, positioned flexibly in chamber or load, for local temperature measurement (up to 3 additional sensors are possible). The measured temperature can, if required, be indicated on the display, recorded in the integral data store, and can be documented via the AtmoCONTROL software |
H8
|
|
4 – 20 mA current loop interface (0 to +90°C = 4 - 20 mA) |
V3
|
|
Flexible Pt100 temperature sensor, positioned flexibly in chamber or load, for local temperature measurement (up to 2 additional sensors are possible). The measured temperature can, if required, be indicated on the display, recorded in the integral data store, and can be documented via the AtmoCONTROL software |
H8
|
|
4 – 20 mA current loop interface (0 to +260 °C ≙ 4 - 20 mA)
Temperature controller actual value |
V3
|
|
4 – 20 mA current loop interface (0 to +260 °C ≙ 4 - 20 mA)
Temperature of a Pt100 sensor positioned flexibly in chamber fo external temperature monitoring (max. 1 SingledDISPLAY, max. 3 TwinDISPLAY) - price per sensor |
V6
|
|
Locking mechanism to prevent simultaneous opening of doors for contamination protection in case of wall installation |
D5
|
|
Light module warm white 2,700 K: light strips arranged on the side walls of the interior, 10 for model 110, 14 for model 260/400/750, programme-controlled dimming from 0 to 100 % (in 1 % steps), ramp programming in combination with temperature (only with TwinDisplay) |
T9
|
|
Premium module: comprises the inert gas inlet (only size 49 and 101), extra connectors for thermoshelves, 1 (size 29), 2 (sizes 49/101), an additional thermoshelf (sizes 49/101) |
T5
|
|
Works calibration certificate for 3 temperatures: +50 °C, +100 °C, +160 °C at 20 mbar pressure. Price per thermoshelf |
D00115
|
|
Temperature restriction; Temperatures: +60, +70, +80, +95, +100, +120, +160 or +180 °C (Please, indicate upon ordering) |
A8
|
|
MobileALERT for 2 alarm notifications; temperature and vacuum alarm (only with option T5) |
C4
|
|
Flexible Pt100 for positioning in chamber or in load with socket, 4-pin, according to NAMUR NE 28, for external temperature recording (load temperature) |
H4
|
|
Potential-free contact (24 V/2 A) with socket, according to NAMUR NE 28 for combination error message (e.g. supply failure, sensor fault, fuse) |
H6
|
|
Freely positioned control sensor, MIN and MAX alarm adjustable at ControlCOCKPIT, alarm values captured in internal data logger |
H9
|
|
4 – 20 mA current loop interface (only with option T5)
Temperature of a Pt100 sensor positioned flexibly in chamber for external
temperature monitoring - price per sensor |
V6
|
|
4 – 20 mA current loop interface (only with option T5)
Vacuum actual value (0 bis 1200 mbar = 4 - 20) |
W2
|
|
4 – 20 mA current loop interface (only with option T5)
Temperature actual value (0 to 210 °C = 4 - 20 m) |
V3
|
|
4 – 20 mA current loop interface
O2 controller, actual value (0 – 25 % O2 4 – 20 mA) |
V1
|
|
4 – 20 mA current loop interface
CO2 controller, actual value (0 – 25 % CO2 4 – 20 mA) |
V9
|
|
Castor frame (2-part), height 140 mm |
|
|
4 – 20 mA current loop interface
Humidity controller, actual value (0 – 100 % rh 4 – 20 mA) |
V7
|
|
Works calibration certificate for one temperature according to customer specification (only TTC) |
D00109
|
|
Start-up of ICOmed incubators and brief training (D, A, CH only), through Memmert service,
not subject to discount |
K9
|
|
Works calibration certificate for 5 %, 7 % and 10 % CO2 (measured at +37 °C)
special works calibration certificates upon request |
D00106
|
|
4 – 20 mA current loop interface
Temperature controller, actual value (0 to +70 °C 4 – 20 mA) |
V3
|
|
Inner door with partitioned glass doors (cannot be used in connection with option B8) |
K4
|
|
Entry port (silicone), 40 mm clear diameter, for introducing connections, moisture tight,
can be closed by silicone stopper, at the back, centre right; not available for ICO50med with
active humidity control (option K7) or humidity display (option K6) |
F7
|
|
Capacitive humidity sensor for measuring and displaying the relative humidity |
K6
|
|
Peltier cooling unit
enables a working temperature of 37 °C even at higher ambient temperatures of up to 35 °C |
K5
|
|
Control of oxygen concentration by N2 inlet; adjustment range 1 % up to 20 % O2; setting accuracy 0.1 % (requires option K7) |
T6
|
|
Active microprocessor control for humidifying and dehumidifying (40 – 97 % rh), incl. digital
indication and auto-diagnostic system ensures even more rapid reaching of set humidity and very
short recovery times while avoiding condensate formation. Humidity supply with distilled water
(from an external tank) by a self-priming pump; integral bacteria block by generating hotsteam,
dehumidifying via sterile filter |
K7
|
|
Electropolished interior |
T2
|
|
MobileALERT for up to 4 alarm notifications; standard: temperature
and CO2 alarm, additionally humidity alarm (when equipped with
option K7) and O2 alarm (when equipped with option T6) |
C4
|
|
Battery-buffered ControlCOCKPIT. Uninterrupted supply for the entire display unit (ControlCOCKPIT) and therefore complete documentation of all parameteres even when there is a power failure. The CO2 parameter is continously regulated. |
C2
|
|
Voltage 115 V, 50/60 Hz (no extra cost) |
X2
|
|
Extended overtemperature protection for SingleDISPLAY devices by additionally integrated Pt100 sensor for independent temperature monitoring for models UN/UF |
A6
|
|
Full-sight glass door (4 insulating glass). Temperature-range up to max. 250 °C. |
B0
|
|
Full-sight glass door (4 insulating glass). Temperature-range up to max. 300 °C - extra cost |
B1
|
|
Fresh-air filter (filtration efficiency 80 %) mounted at the bottom (for UF/UFplus). For model sizes 30 – 260, subframe or subframe on castors obligatory |
R8
|
|
Interior lighting for observing the load |
R0
|
|
Interior socket (can only be ordered with limited temperature-range – max. +70°C - option A8 necessary) current carrying ampacity 230 V, 2.2 A can be switched off with the On/Off switch, cannot be switched individually, moisture tight IP68 |
R3
|
|
Interior nearly gastight |
K2
|
|
Interior nearly gastight with possibility for inlet/outlet through 2 tubes with ball valves |
K3
|
|
Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position left centre/centre |
F0
|
|
Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position left centre top |
F1
|
|
Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position right centre/centre |
F2
|
|
Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position right centre top |
F3
|
|
Entry port, 23 mm clear diameter for introducing connections at the side, can be closed by flap in special positions (please, state location) - left |
F4
F1
|
|
Entry port, 23 mm clear diameter for introducing connections at the side, can be closed by flap in special positions (please, state location) - right |
F5
|
|
Entry port, 23 mm clear diameter for introducing connections, can be closed by flap in special positions (please, state location) - rear |
F6
|
|
Entry port, 14 mm clear diameter, can be closed by flap, in special positions at the back (please, state location) |
D6
|
|
Entry port, 38 mm clear diameter, can be closed by flap, in special positions at the back (please, state location) |
F7
|
|
Entry port, 57 mm clear diameter, can be closed by flap, in special positions at the back (please, state location) |
F8
|
|
Entry port, 100 mm clear diameter, can be closed by flap, in special positions at the back (please, state location) |
F9
|
|
4 – 20 mA current loop interface (0 to +310°C corresponds to 4 – 20 mA)
Temperature controller actual value |
V3
|
|
4 – 20 mA current loop interface (0 to +310°C corresponds to 4 – 20 mA)
Temperature of a Pt100 sensor positioned flexibly in chamber for external temperature monitoring
(max. 1 SingleDISPLAY, max. 3 TwinDISPLAY) |
V6
|
|
Fan speed monitoring with switching off the heating and with alarm in case of failure – optional for UFplus only |
V4
|
|
Works calibration certificate for 3 temperatures: +100°C, +160°C, +220°C. Standard works calibration certificate (measuring point chamber centre) at +160°C |
D00128
|
|
Chamber modification for the application of reinforced perforated stainless steel shelves or stainless steel grids (bearing rails mounted in the working chamber) – includes replacement of 2 standard grids by 2 reinforced grids |
K1
|
|
Extended overtemperature protection for SingleDISPLAY devices by additionally integrated Pt100 sensor for independent temperature monitoring for models IN/IF |
A6
|
|
Interior socket (can only be ordered with limited temperature-range – max. +70°C - option A8 necessary) current carrying ampacity 230 V, 2.2 A can be switched off with the On/Off switch, cannot be switched individually, moisture tight IP68
(only with SingleDISPLAY) |
R3
|
|
4 – 20 mA current loop interface (0 to +90°C corresponds to 4 – 20 mA)
Temperature controller actual value |
V3
|
|
4 – 20 mA current loop interface (0 to +90°C corresponds to 4 – 20 mA)
Temperature of a Pt100 sensor positioned flexibly in chamber for external temperature monitoring
(max. 1 SingleDISPLAY, max. 3 TwinDISPLAY) |
V6
|
|
Fan speed monitoring with switching off the heating and with alarm in case of failure – optional for IFplus only |
V4
|
|
Works calibration certificate for 3 temperatures: +37°C, +52°C, +70°C. Standard works calibration certificate (measuring point chamber centre) at +37°C |
D00126
|
|
Extended overtemperature protection for SingleDISPLAY devices by additionally integrated Pt100 sensor for independent temperature monitoring for models SN/SF |
A6
|
|
Fresh-air filter (filtration efficiency 80 %) mounted at the bottom (for SF/SFplus). For model sizes 30 – 260, subframe or subframe on castors obligatory |
R8
|
|
4 – 20 mA current loop interface (0 to +260°C corresponds to 4 – 20 mA)
Temperature controller actual value |
V3
|
|
4 – 20 mA current loop interface (0 to +260°C corresponds to 4 – 20 mA)
Temperature of a Pt100 sensor positioned flexibly in chamber for external temperature monitoring
(max. 1 SingleDISPLAY, max. 3 TwinDISPLAY) |
V6
|
|
Fan speed monitoring with switching off the heating and with alarm in case of failure – optional for SFplus only |
V4
|
|
Works calibration certificate for 3 temperatures: +160°C, +180°C, +250°C. Standard works calibration certificate (measuring point chamber centre) at +160°C |
D00132
|
|
Inert gas inlet:
programmable and digitally controlled inlet for inert gas with flow rate reduction |
W5
|
|
Premium module: comprises the inert gas inlet (only size 49 and 101), extra connectors for thermoshelves, 1 (size 29), 2 (sizes 49/101), an additional thermoshelf (sizes 49/101) |
|
|
Works calibration certificate for 3 temperatures: +50°C, +100°C, +160°C at 20 mbar pressure |
D00115
|
|
Extended temperature-range (0°C to +90°C) |
A8
|
|
Works calibration certificate for 3 temperatures: +5°C, +30°C, +90°C at 20 mbar pressure |
D00133
|
|
Interior socket, ampacity 230 V/2.2 A, can be switched off with the On/Off switch, cannot be switched individually, moisture tight IP68 |
R3
|
|
4 – 20 mA current loop interface (-10 to +80°C corresponds to 4 – 20 mA)
Temperature controller actual value |
V3
|
|
4 – 20 mA current loop interface (-10 to +80°C corresponds to 4 – 20 mA)
Temperature of a Pt100 sensor positioned flexibly in chamber for external temperature monitoring
(max. 1 SingleDISPLAY, max. 3 TwinDISPLAY) |
V6
|
|
Works calibration certificate for 3 temperatures: +5°C, +37°C, +60°C. Standard works calibration certificate (measuring point chamber centre) at +10°C and +37°C |
D00129
|
|
Light module cold white 6,500 Kelvin: light strips arranged on the side walls of the interior, 10 strips for model 110, 14 for model 260/750, programme-controlled dimming from 0 to 100 % (in 1 % steps), ramp programming in combination with temperature (only with TwinDISPLAY) |
T7
|
|
Light module warm white 2,700 K: light strips arranged on the side walls of the interior, 10 for model 110, 14 for model 260/400/750, programme-controlled dimming from 0 to 100 % (in 1 % steps), ramp programming in combination with temperature and humidity |
T9
|
|
Light module cold white 6,500 Kelvin + warm white 2,700 Kelvin: LED light strips -10 strips for model 110, 14 for model 260/750 - (5 resp. 7 alternating cold white light strips and 5 resp. 7 warm white light strips) on the side walls of the interior, programmecontrolled dimming from 0 to 100 % (in 1 % steps), ramp programming in combination with temperature (only with TwinDISPLAY) |
T8
|
|
Voltage 115 V, 50/60 Hz |
X2
|
|
4 – 20 mA current loop interface (-20 to +70°C corresponds to 4 – 20 mA)
Temperature controller actual value |
V3
|
|
4 – 20 mA current loop interface (-20 to +70°C corresponds to 4 – 20 mA)
Temperature of a Pt100 sensor positioned flexibly in chamber for external temperature monitoring (max. 3 TwinDISPLAY) |
V6
|
|
Fan speed monitoring with switching off the heating and with alarm in case of failure |
V4
|
|
Entry port (silicone), 40 mm clear diameter, for introducing connections, moisture tight, can be closed by silicone stopper, at the back (please, state location) |
F7
|
|
Works calibration certificate for 3 temperatures: 0°C, +37°C, +60°C. Standard works calibration certificate (measuring point chamber centre) at +10°C and +37°C |
D00130
|
|
Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position left centre/centre |
F0
|
|
Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position left centre top |
F1
|
|
Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position right centre/centre |
F2
|
|
Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position right centre top |
F3
|
|
Entry port, 23 mm clear diameter for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper (please, state location) - left |
F4
|
|
Entry port, 23 mm clear diameter for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper (please, state location) - right |
F5
|
|
Entry port, 23 mm clear diameter for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper (please, state location) - rear |
F6
|
|
4 – 20 mA current loop interface (-10 to +80°C corresponds to 4 to 20 mA)
Temperature controller, actual value |
V3
|
|
4 – 20 mA current loop interface (-10 to +80°C corresponds to 4 to 20 mA)
Temperature of a Pt100 sensor positioned flexibly in chamber for external temperature monitoring (max. 3 TwinDISPLAY) |
V6
|
|
4 – 20 mA current loop interface (-10 to +80°C corresponds to 4 to 20 mA)
Humidity controller, actual value (0 – 100 % rh corresponds to 4 – 20 mA) |
V7
|
|
Works calibration certificate for one (freely selectable) temperature and humidity value. Standard works calibration certificate (measuring point chamber centre) at +10°C, +37°C and 60 % rh at +30°C (sizes 1060/1400 for +25 °C/40 % rh and +40 °C/75 % rh) |
|
|
Compressed air dehumidification (efficient dehumidification of the interior by means of compressed air). Standard works calibration certificate (measuring point chamber centre) at +10 °C with 10 % rh. |
C9
|
|
Door-hinges on left side |
B8
|
|
Works calibration certificate for 80 % rh (measured at +50°C) |
D00107
|
|
Start-up of HCP and brief training (D, A, CH only) through MEMMERT service, (not subject to discount) |
K9
|
|
Stacking version for 2 units of equal size (bottom unit modification) |
G3
|
|
Process-dependent electromagnetic door lock |
D4
|
|
Water level control (for WNB, WNE, WPE) |
L3
|
|
Works calibration certificate (37°C for WNB, WNE, WPE, 160°C for ONE) |
D00123
|
|
Adjustable temperature limiter, safety device class 2
instead of adjustable overheat controller safety
device class 3.1, no extra cost |
|
|
Full-sight glass door triple-insulating glass) |
B0
|
|
Reinforced chamber (max. loading up to 300 kg (involves narrower reinforced grids) includes replacement of 2 standard grids by 2 reinforced grids |
|
|
Process-dependent electromagnetic door lock (both sides) |
D4
|
|
Locking mechanism with SPS control to prevent simultaneous opening of doors for contamination protection in case of wall installation |
|
|
Works calibration certificate for one temperature and humidity according to customer specification (only CTC) |
D00105
|
|
Full-sight glass door (5-layer insulating glazing), heated |
B0
|
|
Entry port, left, 80 mm, with stopper |
F0
|
|
Start-up of CTC and TTC chambers and brief training (D, A, CH only) through Memmert service, (not subject to discount) |
K9
|
|
Entry port, 23 mm clear diameter, for introducing connections at the side, gas tight, can be closed by flap and silicone stopper, standard position left centre/centre |
F0
|
|
Entry port, 23 mm clear diameter, for introducing connections at the side, gas tight, can be closed by flap and silicone stopper, standard position left centre top |
F1
|
|
Entry port, 23 mm clear diameter, for introducing connections at the side, gas tight, can be closed by flap and silicone stopper, standard position right centre/centre |
F2
|
|
Entry port, 23 mm clear diameter, for introducing connections at the side, gas tight, can be closed by flap and silicone stopper, standard position right centre top |
F3
|
|
Entry port, 23 mm clear diameter for introducing connections at the side, gas tight, can be closed by flap and silicone stopper, in special positions (please, state location) - left |
F4
|
|
Entry port, 23 mm clear diameter for introducing connections at the side, gas tight, can be closed by flap and silicone stopper, in special positions (please, state location) - right |
F5
|
|
Entry port, 23 mm clear diameter for introducing connections at the side, gas tight, can be closed by flap and silicone stopper, in special positions (please, state location) - rear |
F6
|
|
Entry port, 40 mm clear diameter, for introducing connections, gas tight, can be closed by flap and silicone stopper, in special positions at the back (please, state location) |
F7
|
|
4 – 20 mA current loop interface (0 to +90°C corresponds to 4 – 20 mA)
Temperature of a Pt100 sensor positioned flexibly in chamber for external temperature monitoring
(max. 3 TwinDISPLAY) |
V6
|
|
Gas inlet/outlet through 2 tubes with ball valves |
K3
|
|
Works calibration certificate for 3 temperatures: +37°C, +52°C, +70°C. Standard works calibration certificate (measuring point chamber centre) at +80°C |
D00126
|
|
4 – 20 mA current loop interface (0 to +70°C corresponds to 4 – 20 mA)
Temperature controller actual value |
V3
|
|
4 – 20 mA current loop interface (0 to +70°C corresponds to 4 – 20 mA)
Temperature of a Pt100 sensor positioned flexibly in chamber for external temperature monitoring (max. 1 SingleDISPLAY) |
V6
|
|
Entry port, 120 mm clear diameter, can be closed by flap, in special positions at the back (please, state location) |
|
|
Alternative light boxes (replace the standard lighting; have to be ordered together with the chamber); number of fluorescent lamps: size 110: 5, sizes 260/750: 6, with cold white light (daylight: light colour 865, 6.500K; daylight complies with standard illuminant D65) (only ICHeco L/ICH L) one box |
T81
|
|
Alternative light boxes (replace the standard lighting; have to be ordered together with the chamber); number of fluorescent lamps: size 110: 5, sizes 260/750: 6, with cold white light (daylight: light colour 865, 6.500K; daylight complies with standard illuminant D65) (only ICHeco L/ICH L) second box (cannot be switched on separately) |
T82
|
|
Alternative light boxes (replace the standard lighting, have to be ordered together with the chamber), number of fluorescent UV lamps: size 110: 5, sizes 260/750: 6, in the spectral range of 315 to 400 nm, 22 W/m2, (only ICH L) one box, no extra cost |
T01
|
|
4 to 20 mA current loop interface (-20 to +70°C corresponds to 4 to 20 mA)
(Models ICH C max. 2 interfaces – only combination V3 + V7 or V3 + V9 possible)
Temperature controller, actual value |
V3
|
|
4 to 20 mA current loop interface (-20 to +70°C corresponds to 4 to 20 mA)
(Models ICH C max. 2 interfaces – only combination V3 + V7 or V3 + V9 possible)
Temperature of a Pt100 sensor positioned flexibly in chamber for external temperature monitoring (max. 3 TwinDISPLAY) |
V6
|
|
4 to 20 mA current loop interface (-20 to +70°C corresponds to 4 to 20 mA)
(Models ICH C max. 2 interfaces – only combination V3 + V7 or V3 + V9 possible)
Humidity controller, actual value (0 – 100 % corresponds to rh 4 – 20 mA) |
V7
|
|
4 to 20 mA current loop interface (-20 to +70°C corresponds to 4 to 20 mA)
(Models ICH C max. 2 interfaces – only combination V3 + V7 or V3 + V9 possible)
CO2 controller, actual value (0 – 25 % CO2 corresponds to 4 – 20 mA) |
V9
|
|
Works calibration certificate for one (freely selectable) temperature and humidity value. Standard works calibration certificate (measuring point chamber centre) at +10°C, +37°C and +30°C with 60 % rh |
D00105
|
|
Compressed air dehumidification (efficient dehumidification of the interior by means of compressed air – for models ICH and ICH L). Standard works calibration certificate (measuring point chamber centre) at +10 °C with 10 % rh. |
C9
|
|
Illumination unit consisting of 4 fluorescent lights with cold white light (standard illuminant D65, 6,500 K) and 2 UV lamps in the spectral range of 320 to 400 nm, 8 W/m2, acc. ICH Q1B option 2, light intensity approx. 8,000 Lux, separately switchable via controller (only ICH L) second box |
T72
|
|
Alternative light boxes (replace the standard lighting, have to be ordered together with the chamber), number of fluorescent UV lamps: size 110: 5, sizes 260/750: 6, in the spectral range of 315 to 400 nm, 22 W/m2, (only ICH L) second box, cannot be switched on seperately |
T02
|
|
Chamber modification for the application of reinforced perforated stainless steel shelves or stainless steel grids (bearing rails mounted in the working chamber) – includes replacement of 2 standard grids by 2 reinforced grids (ICH and ICH C only) |
K1
|
|
Two gas connections with quick release connectors, automatic switch-over of gas cylinders; incl. two CO2 connection sets: hose with coupling and clamp |
T1
|
|
Hygiene module:
electropolished interior seamlessly welded by laser |
T2
|
|
Communication module:
USB interface, "Celsius" standard software for programming and logging, ring log memory, printer interface |
T3
|
|
CO2 module:
extended CO2 range from 0 to 20 % |
T4
|
|
Premium module:
includes Comfort, Hygiene, Communication and CO2 module |
T5
|
|
Humidity-Modul:
active microprocessor control for humidifying and dehumidifying
(40-97 % rh), incl. digital indication and auto-diagnostic
system ensures even more rapid reaching
of set humidity and very short recovery times while
avoiding condensate formation, recommended for applications with set O2 values of less than 10 %, humidity supply with
distilled water (from an external tank)
by a self-priming pump, integral bacteria block by generating
hotsteam, dehumidifying via sterile filter, (standard humidity
limit control and water dishes are omitted). Can only
be ordered together with new incubator |
K7
|
|
O2 module:
control of oxygen concentration by N2 inlet,
adjustment range 1 % up to 20 % O2,
setting accuracy 0,1 %, (Combination of comfort module or Premium module and O2 module not possible),
for applications with a set O2-value of less than 10 %, the humidity module is highly recommended. |
T6
|
|
Entry port (silicone), 40 mm clear diameter, for introducing connections, moisture tight, can be closed by silicone stopper, at the back either centre right or centre left (please, state location) |
F7
|
|
Potential-free contact (24V/2A) with socket 3 pin,
according to NAMUR NE 28 for external monitoring
(setpoint of temperature and CO2 is reached) |
H5
|
|
Works calibration certificate for 5 %, 7 % and 10 % CO2 (measured at +37°C) |
D00106
|
|
Start-up of INCO incubators and brief training (D, A, CH only), through MEMMERT service, not subject to discount |
K9
|
|
4-part partitioning of interior with gas baffle
(replacement of 3 full-width by 6 half-width shelves) |
K4
|
|
Interface Ethernet instead of USB including software |
W4
|
|
RS232 interface instead of USB |
W6
|
|
Computer interface RS485 (for networking a max. of 16 ovens) instead of RS232 |
V2
|
|
Door with lock (safety lock, not available for VO, VOcool, TTC/CTC) |
B6
|
|
Flexible Pt100 for positioning in chamber or in load with socket, 4-pin, according to NAMUR NE 28, for external temperature recording (load temperature) |
H4
|
|
Flexible Pt100 temperature sensor, positioned flexibly in chamber or load, for local temperature measurement (up to 3 additional sensors are possible). The measured temperature can, if required, be indicated on the multifunction display, recorded in the integral ring store, and can be documented via the “Celsius” software or on an attached printer. (not available for VO, VOcool, TTC and CTC) |
H8
|
|
Potential-free contact (24 V/2 A) with socket, according to NAMUR NE 28 for external monitoring (indicates when setpoint is reached); VO only in combination with option T5 |
H5
|
|
Potential-free contact (24 V/2 A) with socket, according to NAMUR NE 28 for combination error message (e.g. supply failure, sensor fault, fuse); VO only in combination with option T5 |
H6
|
|
Potential-free contact (24 V/2 A) with socket, according to NAMUR NE 28, triple, for signal generation, controlled by programme segment for a total of 3 freely selected functions to be activated (e.g. acoustic and visual signals, exhaust motors, fans, stirrers etc.) |
H7
|
|
Door with lock (safety lock), Standard with SN/SF and SNplus/SFplus 450 and 750 |
B6
|
|
Door with lock (safety lock), two locks (one each door) |
B62
|
|
Door with lock (safety lock), three locks (one each door) |
B63
|
|
Door hinged on the left |
B8
|
|
Potential-free contact (24 V/2 A) with socket to NAMUR NE 28 for external monitoring (indicates when setpoint is reached) |
H5
|
|
Potential-free contact for combination error message (e.g. supply failure, sensor fault, fuse) |
H6
|
|
Potential-free contact (24 V/2 A) with socket to NAMUR NE 28, for signal generation, controlled by programme segment, for free-selectable functions to be activated (e.g. activation of audible and visual signals, exhaust motors, fans, stirrers, etc. Only for units with TwinDISPLAY; max 2 contacts on 1-phase appliances; max 4 contacts on 3-phase appliances, 2 contacts |
H7
H72
|
|
Process-dependent programmable door lock (only for units with TwinDISPLAY) |
D4
|
|
Process-dependent programmable door lock, two interlocking systems (one each other) |
D42
|
|
Process-dependent programmable door lock, three interlocking systems (one each other) |
D43
|
|
Door-open-recognition (only for units with TwinDISPLAY) |
V5
|
|
Door-open-recognition, two (one each door) |
V52
|
|
Door-open-recognition, three (one each door) |
V53
|
|
Flexible Pt100 for positioning in chamber or in load with socket, 4-pin, according to NAMUR NE 28, for external temperature recording (load temperature) max. 3 sensors |
H4
|
|
Additional Pt100 temperature sensor, positioned flexibly in chamber or load, for local temperature measurement (up to 3 additional sensors are possible). The measured temperature can, if required, be indicated on the display, recorded in the integral ring store, and can be documented via the AtmoCONTROL software. |
H8
|
|
MobileALERT, notification by SMS in case of any error or alarm of the device. Requires option H6 “floating contact for alarm” |
C3
|
|
Temperature restriction (for models UN/UF/UNplus/UFplus, IN/IF/INplus/IFplus) Temperatures: +60, +70, +80, +95, +100, +120, +160, +180, +200 or +220 °C (Please, indicate upon ordering) |
A8
|
|
Castor frame (2-part), height 140 mm |
R9
|
|
Potential-free contact (24 V/2 A) with socket to NAMUR NE 28, for signal generation, controlled by programme segment, for a total of 3 freely selectable functions to be activated (e.g. activation of audible and visual signals, exhaust motors, fans, stirrers, etc. (only for units with TwinDISPLAY), max 2 contacts for 1-ph. units, max 4 contacts for 3-ph. units,4 contacts |
H74
|