Options / Accessories / Services

Options Order No.
Temperature restriction; Temperature: +60 °C A8
Voltage 115 V, 50/60 Hz (no extra cost) X2
Premium module: comprises the inert gas inlet, extra connectors for thermoshelves, 1 (size 29), 2 (sizes 49/101), an additional thermoshelf (sizes 49/101) T5
Inert gas inlet: programmable and digitally controlled inlet for inert gas with flow rate reduction
Premium module: comprises the inert gas inlet (only size 49 and 101), extra connectors for thermoshelves, 1 (size 29), 2 (sizes 49/101), an additional thermoshelf (sizes 49/101)
Voltage 115 V, 50/60 Hz (no extra cost) X2 A6
Voltage 115 V, 50/60 Hz X2
Temperature restriction (for models UN/UF/UNplus/UFplus, IN/IF/INplus/IFplus) Temperatures: +60, +70, +80, +95, +100, +120, +160, +180, +200 or +220 °C (Please, indicate upon ordering) A8
Battery-buffered ControlCOCKPIT. Uninterrupted supply for the entire display unit (ControlCOCKPIT) and therefore complete documentation of all parameteres even when there is a power failure. The CO2 parameter is continously regulated. C2
Battery-buffered ControlCOCKPIT. Uninterrupted supply for the entire display unit (ControlCOCKPIT) and therefore complete documentation of all parameteres even when there is a power failure. C2
Two gas connections with quick release connectors, automatic switch-over of gas cylinders; incl. two CO2 connection sets: hose with coupling and clamp T1
Extended overtemperature protection by additionally integrated Pt100 sensor for independent temperature monitoring for models with SingleDISPLAY A6
Temperature restriction - Temperatures: +50, +55, +60, +65, +70 or +75 °C (Please, indicate upon ordering) A8
Temperature restriction - Temperatures: +60, +70, +80, +95, +100, +120, +160, +180, +200 or +250 °C (Please, indicate upon ordering) A8
Full-sight glass door (4 insulating glass). Temperature-range up to max. 250 °C. Full-sight glass door (4 insulating glass). Temperature-range up to max. 250 °C. B0
Gas inlet/outlet through 2 tubes with ball valves - technical clarification required for combination with other options K3
Full-sight glass door (4-layer insulating glass), temperature range up to max. +250 °C (requires option A8 against surcharge) Full-sight glass door (4-layer insulating glass), temperature range up to max. +250 °C (requires option A8 against surcharge) B0
Full-sight glass door (4 insulating glass). Temperature-range up to max. 300 °C. Full-sight glass door (4 insulating glass). Temperature-range up to max. 300 °C. B1
Chamber modification for the application of reinforced perforated stainless steel shelves or stainless steel grids (bearing rails mounted in the working chamber) - includes replacement of standard grids by reinforced grids (standard with 1060) K1
Full-sight glass door triple-insulating glass) Full-sight glass door triple-insulating glass)
Chamber modification for the application of reinforced perforated stainless steel shelves or stainless steel grids (bearing rails mounted in the working chamber) – includes replacement of standard grids by reinforced grids K1
Interior lighting for observing the load Interior lighting for observing the load R0
Chamber modification for the application of reinforced perforated stainless steel shelves or stainless steel grids (bearing rails mounted in the working chamber) - includes replacement of standard grids by reinforced grids (ICHeco/ICH only) K1
Light module cold white 6,500 K: LED light strips arranged on the side walls of the interior,10 for model 110, 14 for model 260/410/750,programme controlled dimming from 0 to 100% (in 1 % steps), ramp programming in combination with temperature and humidity (not in combination with F6, F7, D8) T7
Light module cold white 6,500 K: LED light strips arranged on the side walls of the interior, 10 for model 110, 14 for model 260/410/750, programme controlled dimming from 0 to 100 % (in 1 % steps), ramp programming in combination with temperature and humidity; not in combination with F6 T7
Light module cold white 6,500 K: light strips arranged on the side walls of the interior, 10 strips for model 110, 14 for model 260/400/750, programme-controlled dimming from 0 to 100 % (in 1 % steps), ramp programming in combination with temperature (only with TwinDISPLAY; not in combination with F6, F7, D8) T7
Light module cold white 6,500 K: light strips arranged on the side walls of the interior, 10 strips for model 110, 14 for model 260/410/750, programme-controlled dimming from 0 to 100 % (in 1 % steps), ramp programming in combination with temperature (only with TwinDISPLAY; not in combination with F6) T7
Light module cold white 6,500K + warm white 2,700K: LED light strips - 10 stripes for model 110, 14 for model 260/410/750 (6 resp. 8 alternating coldwhite light strips and 4 resp. 6 warm white light strips) on the side walls of the interior, programme-controlled dimming from 0 to100% (in 1 % steps), ramp programming in combination with temperature and humidity (not in combination with F6, F7, D8) T8
Light module cold white 6,500 K + warm white 2,700 K: LED light strips - 10 stripes for model 110, 14 for model 260/410/750 - (5 resp. 7 alternating cold white light strips and 5 resp. 7 warm white light strips) on the side walls of the interior, programme-controlled dimming from 0 to 100 % (in 1 % steps), ramp programming in combination with temperature and humidity; not in combination with F6 T8
Light module cold white 6,500 Kelvin + warm white 2,700 Kelvin: LED light strips -10 strips for model 110, 14 for model 260/400/750 - (6 resp. 8 alternating cold white light strips and 4 resp. 6 warm white light strips) on the side walls of the interior, programme-controlled dimming from 0 to 100 % (in 1 % steps), ramp programming in combination with temperature (only with TwinDISPLAY; not in combination with F6, F7, D8) T8
Light module cold white 6,500 K + warm white 2,700 K: LED light strips - 10 strips for model 110, 14 for model 260/410/750 - (5 resp. 7 alternating cold white light strips and 5 resp. 7 warm white light strips) on the side walls of the interior, programme-controlled dimming from 0 to 100 % (in 1 % steps), ramp programming in combination with temperature (only with TwinDISPLAY; not in combination with F6) T8
Light module warm white 2,700 K: light strips arranged on the side walls of the interior, 10 for model 110, 14 for model 260/400/750, programme-controlled dimming from 0 to 100 % (in 1 % steps), ramp programming in combination with temperature (only with TwinDisplay; not in combination with F6, F7, D8) T9
Light module warm white 2,700 K: light strips arranged on the side walls of the interior, 10 strips for model 110, 14 for model 260/410/750, programme-controlled dimming from 0 to 100 % (in 1 % steps), ramp programming in combination with temperature (only with TwinDISPLAY; not in combination with F6) T9
Light module warm white 2,700 K: light strips arranged on the side walls of the interior, 10 strips for model 110, 14 for model 260/400/750, programme-controlled dimming rom 0 to100% (in 1 % steps), ramp programming in combination with temperature and humidity (not in combination with F6, F7, D8) T9
Light module warm white 2,700 K: light strips arranged on the side walls of the interior, 10 strips for model 110, 14 for model 260/410/750, pro­gramme-controlled dimming from 0 to 100 % (in 1 % steps), ramp programming in combination with temperature and humidity; not in combination with F6 T9
Illumination unit (has to be ordered together with the chamber) consisting of 4 fluorescent lights with cold white light and 2 UV lamps according ICH Q1B, option 2, separately switchable via controller (only ICHLeco/ICHL) second box T72
Alternative light boxes (replace the standard lighting; have to be ordered together with the chamber); number of fluorescent lamps: size 110: 5, sizes 260/750: 6, with cold white light according to ICH guideline Q1B, option 2 (only ICHLeco/ICHL); one box T81
Alternative light boxes (replace the standard lighting; have to be ordered together with the chamber); number of fluorescent lamps: size 110: 5, sizes 260/750: 6, with cold white light according to ICH guideline Q1B, option 2 (only ICHLeco/ICHL); second box (cannot be switched on separately) T82
Alternative light boxes (replace the standard lighting; have to be ordered together with the chamber); number of fluorescent UV lamps: size 110: 5, sizes 260/750: 6, with UV-A radiation according to ICH guideline Q1B, option 2 (only ICHLeco/ICHL); one box, no extra cost T01
Alternative light boxes (replace the standard lighting; have to be ordered together with the chamber); number of fluorescent UV lamps: size 110: 5, sizes 260/750: 6, with UV-A radiation according to ICH guideline Q1B, option 2 (only ICHLeco/ICHL); second box, cannot be switched on seperately T02
Interior socket (can only be ordered with limited temperature range - max. +60 °C), ampacity 230V/2, 2A/500W, can be switched off with the On/Off switch, cannot be switched individually, moisture tight IP68 (requires option A8 against surcharge) R3
Interior socket (can only be ordered with limited temperature range - max. +60 °C), ampacity 230V/2, 2A/500W, can be switched off with the On/Off switch, cannot be switched individually, moisture tight IP68 (only with SingleDISPLAY), (option A8 necessary against surcharge) R3
Interior socket (can only be ordered with limited temperature range - max. +60 °C), ampacity 230V/2, 2A/500W, can be switched off with the On/Off switch, cannot be switched individually, moisture tight IP68 (requires option A8 against surcharge) R3
Interior socket (can only be ordered with limited temperature range - max. +70 °C). ampacity 230V/2, 2A/500W, can be switched on/off via tumbler switch in control panel, moisture tight IP68 R4
Interior socket, ampacity 230V/2, 2A/500W, can be switched off with the On/Off switch, cannot be switched individually, moisture tight IP68 (not for ICH110Leco/ICH110L) R3
Interior nearly gastight - technical clarification required for combination with other options K2
Interior nearly gastight with possibility for inlet/outlet through 2 tubes with ball valves - technical clarification required for combination with other options K3
Electropolished interior T2
Active microprocessor control for humidifying and dehumidifying (40 - 97 % rh), incl. digital indication and auto-diagnostic system ensures even more rapid reaching of set humidity and very short recovery times while avoiding condensate formation. Humidity supply with water (only for demineralised water with a conductivity of 5 to 10 μS/cm and a pH value between 5and 7; from an external tank) by a self-priming pump; integral bacteria block by generating hot steam, dehumidifying via sterile filter (combination of options K7 and F7 for ICO50med not possible) K7
Active microprocessor control for humidifying and dehumidifying (40 - 97 % rh), incl. digital indication and auto-diagnostic system ensures even more rapid reaching of set humidity and very short recovery times while avoiding condensate formation. Humidity supply with water (only for demineralised water with a conductivity of 5 to 10 μS/cm and a pH value between 5and 7; from an external tank) by a self-priming pump; integral bacteria block by generating hot steam, dehumidifying via sterile filter (combination of options K7 and F7 for ICO50 not possible) K7
Control of oxygen concentration by N2 inlet; adjustment range 1 % up to 20 % O2 ; setting accuracy 0.1 % (requires option K7). Incl. N2 connection set: hose with coupling and clamp T6
Peltier cooling unit enables a working temperature of +37 °C even at higher ambient temperatures of up to +35 °C (combination of options K5 and F7 for ICO50 and ICO105 not possible) K5
Peltier cooling unit: enables low working temperature even at higher ambient temperatures
Capacitive humidity sensor for measuring and displaying the relative humidity K6
Entry port (silicone), 40 mm clear diameter, moisture tight, can be closed by silicone stopper, at the back, centre right; not available for ICO50/ ICO50med with active humidity control (option K7, only in combination with accessory B44128) or humidity display (option K6) F7
Heated inner door with partitioned glass doors; size105/150/240 has 2/3/4 partitioned glass doors K4
Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position left centre/centre Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position left centre/centre F0
Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, standard positions (F0 and F2 not for model size 260 with light module; F0 - F3 not for model size 110 with light module), position left centre/centre Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, standard positions (F0 and F2 not for model size 260 with light module; F0 - F3 not for model size 110 with light module), position left centre/centre F0
Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position left centre top Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position left centre top F1
Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, standard positions (F0 and F2 not for model size 260 with light module; F0 - F3 not for model size 110 with light module), position left centre top Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, standard positions (F0 and F2 not for model size 260 with light module; F0 - F3 not for model size 110 with light module), position left centre top F1
Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position right centre/centre Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position right centre/centre F2
Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, standard positions (F0 and F2 not for model size 260 with light module; F0 - F3 not for model size 110 with light module), position right centre/centre Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, standard positions (F0 and F2 not for model size 260 with light module; F0 - F3 not for model size 110 with light module), position right centre/centre F2
Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position right centre top Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position right centre top F3
Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, standard positions (F0 and F2 not for model size 260 with light module; F0 - F3 not for model size 110 with light module), position right centre top Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, standard positions (F0 and F2 not for model size 260 with light module; F0 - F3 not for model size 110 with light module), position right centre top F3
Entry port, 23 mm clear diameter for introducing connections at the side, can be closed by flap in special positions (please, state location) - left Entry port, 23 mm clear diameter for introducing connections at the side, can be closed by flap in special positions (please, state location) - left F4
Entry port, 23 mm clear diameter for introducing connections at the side, can be closed by flap in special positions (please, state location) - right Entry port, 23 mm clear diameter for introducing connections at the side, can be closed by flap in special positions (please, state location) - right F5
Entry port, 23 mm clear diameter for introducing connections, can be closed by flap in special positions (please, state location) - rear Entry port, 23 mm clear diameter for introducing connections, can be closed by flap in special positions (please, state location) - rear F6
Entry port, 23 mm clear diameter, can be closed by flap in special positions (please, state location) – rear Entry port, 23 mm clear diameter, can be closed by flap in special positions (please, state location) – rear F6
Entry port, 14 mm clear diameter, can be closed by flap, in special positions at the back (please, state location) Entry port, 14 mm clear diameter, can be closed by flap, in special positions at the back (please, state location) D6
Entry port, 14 mm clear diameter, can be closed by flap, in special positions at the back (please, state location; not in combination with T7, T8, T9) Entry port, 14 mm clear diameter, can be closed by flap, in special positions at the back (please, state location; not in combination with T7, T8, T9) D6
Entry port, 38 mm clear diameter, can be closed by flap, in special positions at the back (please, state location) Entry port, 38 mm clear diameter, can be closed by flap, in special positions at the back (please, state location) F7
Entry port, 38 mm clear diameter, can be closed by flap, in special positions at the back (please, state location; not in combination with T7, T8, T9) Entry port, 38 mm clear diameter, can be closed by flap, in special positions at the back (please, state location; not in combination with T7, T8, T9) F7
Entry port, 57 mm clear diameter, can be closed by flap, in special positions at the back (please, state location; not possible for UF/UFplus/UFm/UFmplus size 30-75) Entry port, 57 mm clear diameter, can be closed by flap, in special positions at the back (please, state location; not possible for UF/UFplus/UFm/UFmplus size 30-75) F8
Entry port, 100 mm clear diameter, can be closed by flap, in special positions at the back (please, state location; not possible for UF/UFplus/UFm/UFmplus size 75) Entry port, 100 mm clear diameter, can be closed by flap, in special positions at the back (please, state location; not possible for UF/UFplus/UFm/UFmplus size 75) F9
Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position left centre/centre Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position left centre/centre F0
Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position left centre top Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position left centre top F1
Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position right centre/centre Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position right centre/centre F2
Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position right centre top Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position right centre top F3
Entry port, 23 mm clear diameter for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper (please, state location) - left Entry port, 23 mm clear diameter for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper (please, state location) - left F4
Entry port, 23 mm clear diameter for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper (please, state location) - right Entry port, 23 mm clear diameter for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper (please, state location) - right F5
Entry port, 23 mm clear diameter for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper (please, state location) - rear Entry port, 23 mm clear diameter for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper (please, state location) - rear
Entry port, 23 mm clear diameter, moisture tight, can be closed by flap and silicone stopper, in special positions (please, state location) – rear Entry port, 23 mm clear diameter, moisture tight, can be closed by flap and silicone stopper, in special positions (please, state location) – rear F6
Entry port, 23 mm clear diameter, for introducing connections at the side, gas tight, can be closed by flap and silicone stopper, standard position left centre/centre - technical clarification required Entry port, 23 mm clear diameter, for introducing connections at the side, gas tight, can be closed by flap and silicone stopper, standard position left centre/centre - technical clarification required F0
Entry port, 23 mm clear diameter, for introducing connections at the side, gas tight, can be closed by flap and silicone stopper, standard position left centre top - technical clarification required Entry port, 23 mm clear diameter, for introducing connections at the side, gas tight, can be closed by flap and silicone stopper, standard position left centre top - technical clarification required F1
Entry port, 23 mm clear diameter, for introducing connections at the side, gas tight, can be closed by flap and silicone stopper, standard position right centre/centre - technical clarification required Entry port, 23 mm clear diameter, for introducing connections at the side, gas tight, can be closed by flap and silicone stopper, standard position right centre/centre - technical clarification required F2
Entry port, 23 mm clear diameter, for introducing connections at the side, gas tight, can be closed by flap and silicone stopper, standard position right centre top - technical clarification required Entry port, 23 mm clear diameter, for introducing connections at the side, gas tight, can be closed by flap and silicone stopper, standard position right centre top - technical clarification required F3
Entry port, 23 mm clear diameter for introducing connections at the side, gas tight, can be closed by flap and silicone stopper, in special positions (please, state location) - left - technical clarification required Entry port, 23 mm clear diameter for introducing connections at the side, gas tight, can be closed by flap and silicone stopper, in special positions (please, state location) - left - technical clarification required F4
Entry port, 23 mm clear diameter for introducing connections at the side, gas tight, can be closed by flap and silicone stopper, in special positions (please, state location) - right - technical clarification required Entry port, 23 mm clear diameter for introducing connections at the side, gas tight, can be closed by flap and silicone stopper, in special positions (please, state location) - right - technical clarification required F5
Entry port, 23 mm clear diameter for introducing connections at the side, gas tight, can be closed by flap and silicone stopper, in special positions (please, state location) - rear - technical clarification required Entry port, 23 mm clear diameter for introducing connections at the side, gas tight, can be closed by flap and silicone stopper, in special positions (please, state location) - rear - technical clarification required F6
Entry port, 40 mm clear diameter, for introducing connections, gas tight, can be closed by flap and silicone stopper, in special positions at the back (please, state location) - technical clarification required F7
Entry port, 120 mm clear diameter, can be closed by flap, in special positions at the back (please, state location) Entry port, 120 mm clear diameter, can be closed by flap, in special positions at the back (please, state location)
Entry port (silicone), 40 mm clear diameter, for introducing connections, moisture tight, can be closed by silicone stopper, at the back either centre right or centre left (please, state location)
Entry port (silicone), 40 mm clear diameter, moisture tight, can be closed by silicone stopper, at the back (please, state location; not in combination with T7, T8, T9) F7
Entry port (silicone), 40 mm clear diameter, moisture tight, can be closed by silicone stopper, at the back (please state location) F7
Entry port (silicone), 40 mm clear diameter, moisture tight, can be closed by silicone stopper, standard position rear D8
Entry port, 57 mm clear diameter, can be closed by flap, in special positions at the back (please, state location; not possible for IF/IFplus/IFm/IFmplus size 30-75) Entry port, 57 mm clear diameter, can be closed by flap, in special positions at the back (please, state location; not possible for IF/IFplus/IFm/IFmplus size 30-75) F8
Entry port, 100 mm clear diameter, can be closed by flap, in special positions at the back (please, state location; not possible for IF/IFplus/IFm/IFmplus size 75) Entry port, 100 mm clear diameter, can be closed by flap, in special positions at the back (please, state location; not possible for IF/IFplus/IFm/IFmplus size 75) F9
Entry port (silicone), 40 mm clear diameter, for introducing connections, moisture tight, can be closed by silicone stopper, at the back (please, state location) Not for models ICHLeco/ICHL F7
Locking mechanism to prevent simultaneous opening of doors for contamination protection in case of wall installation (requires option V5) D5
4 - 20 mA current loop interface, temperature controller, actual value (0 to +100 °C = 4 - 20 mA) V3
4 - 20 mA current loop interface, humidity controller, actual value (0 to 100 % rh = 4 - 20 mA) V7
4 - 20 mA current loop interface, humidity controller, actual value (0 to 100 % rh = 4 - 20 mA) (requires option K7 or K6) V7
Door with lock (safety lock, not available for VO, VOcool, TTC/CTC) B6
4 – 20 mA current loop interface (0 to +260 °C ≙ 4 - 20 mA), temperature controller actual value V3
4 – 20 mA current loop interface (0 to +260 °C ≙ 4 - 20 mA), temperature of a Pt100 sensor positioned flexibly in chamber fo external temperature monitoring (max. 1 SingledDISPLAY, max. 3 TwinDISPLAY) - price per sensor V6
4 – 20 mA current loop interface (only with option T5) Vacuum actual value (0 bis 1200 mbar = 4 - 20)
4 – 20 mA current loop interface (only with option T5), temperature of a Pt100 sensor positioned flexibly in chamber for external temperature monitoring - price per sensor V6
4 – 20 mA current loop interface (only with option T5), temperature actual value (0 to 210 °C = 4 - 20 m) V3
4 – 20 mA current loop interface, CO2 controller, actual value (0 – 25 % CO2 4 – 20 mA) (requires option T6 or K7) V9
4 – 20 mA current loop interface O2 controller, actual value (0 – 25 % O2 4 – 20 mA) (requires option T6 or K7) V1
Heated inner door with partitioned glass doors (cannot be used in connection with option B8); size105/150/240 has 2/3/4 partitioned glass doors K4
4 – 20 mA current loop interface (0 to +310°C corresponds to 4 – 20 mA), temperature controller actual value V3
4 – 20 mA current loop interface (0 to +310 °C corresponds to 4 – 20 mA), temperature of a Pt100 sensor positioned flexibly in chamber for external temperature monitoring (max. 1 SingleDISPLAY, max. 3 TwinDISPLAY) V6
4 – 20 mA current loop interface (0 to +90°C corresponds to 4 – 20 mA), temperature controller actual value V3
4 – 20 mA current loop interface (0 to +90°C corresponds to 4 – 20 mA), temperature of a Pt100 sensor positioned flexibly in chamber for external temperature monitoring (max. 1 SingleDISPLAY, max. 3 TwinDISPLAY) V6
4 – 20 mA current loop interface (-10 to +80°C corresponds to 4 – 20 mA), temperature controller actual value V3
4 – 20 mA current loop interface (-10 to +80°C corresponds to 4 – 20 mA) Temperature of a Pt100 sensor positioned flexibly in chamber for external temperature monitoring (max. 1 SingleDISPLAY, max. 3 TwinDISPLAY) V6
4 – 20 mA current loop interface (-20 to +70°C corresponds to 4 – 20 mA), temperature controller actual value V3
4 – 20 mA current loop interface (-20 to +70°C corresponds to 4 – 20 mA), temperature of a Pt100 sensor positioned flexibly in chamber for external temperature monitoring (max. 3 TwinDISPLAY) V6
4 – 20 mA current loop interface (-10 to +80°C corresponds to 4 to 20 mA), temperature controller, actual value V3
4 – 20 mA current loop interface (-10 to +80°C corresponds to 4 to 20 mA) Temperature of a Pt100 sensor positioned flexibly in chamber for external temperature monitoring (max. 3 TwinDISPLAY) V6
4 – 20 mA current loop interface (-10 to +80°C corresponds to 4 to 20 mA) Humidity controller, actual value (0 – 100 % rh corresponds to 4 – 20 mA) V7
4 – 20 mA current loop interface (0 to +90 °C corresponds to 4 – 20 mA), temperature of a Pt100 sensor positioned flexibly in chamber for external temperature monitoring (max. 3 TwinDISPLAY) V6
4 – 20 mA current loop interface (0 to +70°C corresponds to 4 – 20 mA) Temperature controller actual value
4 – 20 mA current loop interface (0 to +70°C corresponds to 4 – 20 mA) Temperature of a Pt100 sensor positioned flexibly in chamber for external temperature monitoring (max. 1 SingleDISPLAY)
4 to 20 mA current loop interface, temperature controller actual value (-20 to +70 °C = 4 - 20 mA) V3
4 to 20 mA current loop interface, temperature of a Pt100 sensor positioned flexibly in chamber for external temperature monitoring (max. 3) - price per sensor (-20 to +70 °C = 4 - 20 mA) V6
4 to 20 mA current loop interface, humidity controller, actual value (0 to 100 % rh = 4 - 20 mA) V7
Fan speed monitoring with switching off the heating and with alarm in case of failure – optional for UFplus only V4
Fan speed monitoring with switching off the heating and with alarm in case of failure – optional for IFplus only V4
Fan speed monitoring with switching off the heating and with alarm in case of failure V4
Works calibration certificate for 3 temperatures: +50°C, +100°C, +160°C at 20 mbar pressure
Works calibration certificate for 3 temperatures: +5°C, +30°C, +90°C at 20 mbar pressure D00133
Works calibration certificate for 80 % rh (measured at +50°C)
Works calibration certificate for 5 %, 7 % and 10 % CO2 (measured at +37°C)
Works calibration certificate for one (freely selectable) temperature and humidity value. Standard works calibration certificate (measuring point chamber centre) at +10°C, +37°C and 60 % rh at +30°C (sizes 1060/1400 for +25 °C/40 % rh and +40 °C/75 % rh)
Works calibration certificate for one (freely selectable) temperature and humidity value. Standard works calibration certificate (measuring point chamber centre) at +10°C, +37°C and +30°C with 60 % rh
Start-up of HCP and brief training (D, A, CH only) through MEMMERT service, (not subject to discount)
Start-up of CTC and TTC chambers and brief training (D, A, CH only) through Memmert service, (not subject to discount)
Start-up of INCO incubators and brief training (D, A, CH only), through MEMMERT service, not subject to discount
Compressed air dehumidification (efficient dehumidification of the interior by means of compressed air – for models ICH and ICHL). Standard works calibration certificate (measuring point chamber centre) at +10 °C with 10 % rh. C9
Compressed air dehumidification (efficient dehumidification of the interior by means of compressed air). Standard works calibration certificate (measuring point chamber centre) at +10 °C with 10 % rh. C9
Door with lock and key (safety lock) Door with lock and key (safety lock) B6
Door with lock and key (safety lock), two locks (one each door) B62
Door with lock and key (safety lock), three locks (one each door) B63
Door with lock and key (safety lock) B6
Door with lock and key (safety lock); standard with 450 and 750 B6
Full-sight glass door (5-layer insulating glazing), heated B0
Entry port, left, 80 mm, with stopper F0
Door hinged on the left B8
Door-hinges on left side B8
Freely positioned control sensor, MIN and MAX alarm adjustable at ControlCOCKPIT, alarm values captured in internal data logger
Potential-free contact (24 V/2 A) with socket, according to NAMUR NE 28, triple, for signal generation, controlled by programme segment for a total of one freely selected function to be activated (e.g. acoustic and visual signals, exhaust motors, fans, stirrers etc.) Potential-free contact (24 V/2 A) with socket, according to NAMUR NE 28, triple, for signal generation, controlled by programme segment for a total of one freely selected function to be activated (e.g. acoustic and visual signals, exhaust motors, fans, stirrers etc.)
Potential-free contact (24 V/2 A) with socket, according to NAMUR NE 28 for combination error message (e.g. supply failure, sensor fault, fuse) H6
Potential-free contact (24V/2A) with socket 3 pin,
according to NAMUR NE 28 for external monitoring
(setpoint of temperature and CO<sub>2</sub> is reached) Potential-free contact (24V/2A) with socket 3 pin, according to NAMUR NE 28 for external monitoring (setpoint of temperature and CO2 is reached)
Potential-free contact (24 V/2 A) with socket, according to NAMUR NE 28 for external monitoring (indicates when setpoint is reached); VO only in combination with option T5 Potential-free contact (24 V/2 A) with socket, according to NAMUR NE 28 for external monitoring (indicates when setpoint is reached); VO only in combination with option T5 H5
Potential-free contact (24 V/2 A) with socket, according to NAMUR NE 28 for combination error message (e.g. supply failure, sensor fault, fuse); VO only in combination with option T5 Potential-free contact (24 V/2 A) with socket, according to NAMUR NE 28 for combination error message (e.g. supply failure, sensor fault, fuse); VO only in combination with option T5 H6
Interface Ethernet instead of USB including software W4
RS232 interface instead of USB W6
Potential-free contact (24 V/2 A) with socket, according to NAMUR NE 28, triple, for signal generation, controlled by programme segment for a total of 3 freely selected functions to be activated (e.g. acoustic and visual signals, exhaust motors, fans, stirrers etc.) Potential-free contact (24 V/2 A) with socket, according to NAMUR NE 28, triple, for signal generation, controlled by programme segment for a total of 3 freely selected functions to be activated (e.g. acoustic and visual signals, exhaust motors, fans, stirrers etc.) H7
Potential-free contact for combination error message (e.g. supply failure, sensor fault, fuse) Potential-free contact for combination error message (e.g. supply failure, sensor fault, fuse) H6
Potential-free contact (24 V/2 A) with socket to NAMUR NE 28, for signal generation, controlled by programme segment, for free-selectable functions to be activated (e.g. activation of audible and visual signals, exhaust motors, fans, stirrers, etc. Only for units with TwinDISPLAY; max 2 contacts on 1-phase appliances; max 4 contacts on 3-phase appliances, 2 contacts Potential-free contact (24 V/2 A) with socket to NAMUR NE 28, for signal generation, controlled by programme segment, for free-selectable functions to be activated (e.g. activation of audible and visual signals, exhaust motors, fans, stirrers, etc. Only for units with TwinDISPLAY; max 2 contacts on 1-phase appliances; max 4 contacts on 3-phase appliances, 2 contacts H72
Potential-free contact (24 V/2 A) with socket to NAMUR NE 28, for signal generation, controlled by programme segment, for a total of 3 freely selectable functions to be activated (e.g. activation of audible and visual signals, exhaust motors, fans, stirrers, etc. (only for units with TwinDISPLAY), max 2 contacts for 1-ph. units, max 4 contacts for 3-ph. units,4 contacts
Process-dependent electromagnetic door lock
Process-dependent electromagnetic door lock (both sides) D4
Process-dependent programmable door lock (only for units with TwinDISPLAY) D4
Process-dependent programmable door lock, two interlocking systems (one each other) D42
Process-dependent programmable door lock, three interlocking systems (one each other) D43
Door-open-recognition (only for units with TwinDISPLAY) V5
Door-open-recognition, two (one each door) V52
Door-open-recognition, three (one each door) V53
Door-open-recognition, shuts down humidity, light and CO2 (standard with ICHLeco/ICHL) V5
Computer interface RS485 (for networking a max. of 16 ovens) instead of RS232 V2
Flexible Pt100 temperature sensor, positioned flexibly in chamber or load, for local temperature measurement (up to 2 additional sensors are possible). The measured temperature can, if required, be indicated on the display, recorded in the integral data store, and can be documented via the AtmoCONTROL software
Flexible Pt100 for positioning in chamber or in load with socket, 4-pin, according to NAMUR NE 28, for external temperature recording (load temperature) Flexible Pt100 for positioning in chamber or in load with socket, 4-pin, according to NAMUR NE 28, for external temperature recording (load temperature) H4
Flexible Pt100 temperature sensor, positioned flexibly in chamber or load, for local temperature measurement (up to 3 additional sensors are possible). The measured temperature can, if required, be indicated on the multifunction display, recorded in the integral ring store, and can be documented via the “Celsius” software or on an attached printer. (not available for VO, VOcool, TTC and CTC) Flexible Pt100 temperature sensor, positioned flexibly in chamber or load, for local temperature measurement (up to 3 additional sensors are possible). The measured temperature can, if required, be indicated on the multifunction display, recorded in the integral ring store, and can be documented via the “Celsius” software or on an attached printer. (not available for VO, VOcool, TTC and CTC) H8
Flexible Pt100 temperature sensor, positioned fl exibly in chamber or load, for local temperature measurement (up to 1 additional sensor is possible). The measured temperature will be indicated on the display, recorded in the integral data store, and can be documented via the AtmoCONTROL software Flexible Pt100 temperature sensor, positioned fl exibly in chamber or load, for local temperature measurement (up to 1 additional sensor is possible). The measured temperature will be indicated on the display, recorded in the integral data store, and can be documented via the AtmoCONTROL software H8
MobileALERT, notification by SMS in case of any error or alarm of the device (Requires option H6) C3
MobileALERT for 2 alarm notifications; notification by SMS. temperature and vacuum alarm (requires option T5 and H6) C4
MobileALERT for 2 alarm notifications; notification by SMS. temperature and humidity alarm (requires option H6) C4
MobileALERT for up to 4 alarm notifications (requires option H6 and K6 or K7); notification by SMS; temperature and CO2 alarm (standard), additionally humidity alarm (when equipped with option K6 or K7) and O2 alarm (when equipped with option T6) C4
MobileALERT for 2 alarm notifications; notification by SMS. temperature and humidity alarm (requires option H6) C4
Temperature restriction; Temperatures: +60, +70, +80, +95, +100, +120, +160 or +180 °C (Please, indicate upon ordering)
Extended temperature-range (0°C to +90°C)
Castor frame (2-part), height 140 mm Castor frame (2-part), height 140 mm R9
Fresh-air filter (filtration efficiency 80 %) mounted at the bottom (for UF/UFplus). For model sizes 30 – 260, subframe or subframe on castors obligatory Fresh-air filter (filtration efficiency 80 %) mounted at the bottom (for UF/UFplus). For model sizes 30 – 260, subframe or subframe on castors obligatory R8
Communication module: USB interface, "Celsius" standard software for programming and logging, ring log memory, printer interface
Stacking version for 2 units of equal size (bottom unit modification)
Adjustable temperature limiter, safety device class 2 instead of adjustable overheat controller safety device class 3.1, no extra cost
Reinforced chamber (max. loading up to 300 kg (involves narrower reinforced grids) includes replacement of 2 standard grids by 2 reinforced grids
Locking mechanism with SPS control to prevent simultaneous opening of doors for contamination protection in case of wall installation
Hygiene module: electropolished interior seamlessly welded by laser
CO2 module: extended CO2 range from 0 to 20 %
Premium module: includes Comfort, Hygiene, Communication and CO2 module
Humidity-Modul: active microprocessor control for humidifying and dehumidifying (40-97 % rh), incl. digital indication and auto-diagnostic system ensures even more rapid reaching of set humidity and very short recovery times while avoiding condensate formation, recommended for applications with set O2 values of less than 10 %, humidity supply with distilled water (from an external tank) by a self-priming pump, integral bacteria block by generating hotsteam, dehumidifying via sterile filter, (standard humidity limit control and water dishes are omitted). Can only be ordered together with new incubator
O2 module: control of oxygen concentration by N2 inlet, adjustment range 1 % up to 20 % O2, setting accuracy 0,1 %, (Combination of comfort module or Premium module and O2 module not possible), for applications with a set O2-value of less than 10 %, the humidity module is highly recommended.
4-part partitioning of interior with gas baffle (replacement of 3 full-width by 6 half-width shelves)

Services Order No.
Guarantee extension by 1 year GA2Q5 GA4Q5
Guarantee extension by 1 year GA1Q5 GA2Q5 GA3Q5 GA4Q5
Calibration at Memmert factory for three CO2 values: 5 %, 7 %, 10 % (measured at +37 °C), special works calibration certificates available on request D00106
Calibration at Memmert factory for a freely selectable temperature and humidity value D00105
Calibration at Memmert factory for a freely selectable temperature, humidity and CO2 value (requires option K7) D00131
Calibration at Memmert factory for a freely selectable temperature, humidity, CO2 and O2 value (requires option T6) D00143
Calibration at Memmert factory for a freely selectable temperature value D00109
Calibration at Memmert factory for three temperature values: +5, +37, +60 °C Calibration at Memmert factory for three temperature values: +5, +37, +60 °C D00129
Calibration at Memmert factory for three temperature values: 0, +37, +60 °C Calibration at Memmert factory for three temperature values: 0, +37, +60 °C D00130
Calibration at Memmert factory for three temperature values: +37, +52, +70 °C Calibration at Memmert factory for three temperature values: +37, +52, +70 °C D00126
Calibration at Memmert factory for three temperature values: +37, +52, +70 °C D00126
Calibration at Memmert factory for three temperature values: +100, +160, +220 °C Calibration at Memmert factory for three temperature values: +100, +160, +220 °C D00128
Calibration at Memmert factory for a freely selectable temperature and humidity value (only CTC) D00105
Calibration at Memmert factory for a freely selectable temperature value D00109
Calibration at Memmert factory for three temperature values: +50, +100, +160 °C at 20 mbar pressure (price per thermoshelf) D00115
Calbration at Memmert factory for a freely selectable temperature and pressure value (each thermoshelf) D00116
DAkkS calibration for one free-selectable temperature value according to method C (DKD-R 5-7) E39696
Extension of DAkkS calibration at Memmert factory by an additional freely selectable temperature value according to method C (DKD-R 5-7) E39697
DAkkS calibration at Memmert factory for a freely selectable temperature and humidity value according to method C (DKD-R 5-7) (only CTC) E48847
DAkkS calibration at Memmert factory for a freely selectable temperature and humidity value according to method C (DKD-R 5-7) E48847
DAkkS calibration at Memmert factory for a freely selectable temperature and humidity value according to method C (DKD-R 5-7) (requires option K7) E48847
Extension of DAkkS calibration at Memmert factory by an additional freely selectable temperature and humidity value according to method C (DKD-R 5-7) E48848
Extension of DAkkS calibration at Memmert factory by an additional freely selectable temperature and humidity value according to method C (DKD-R 5-7) (only CTC) E48848
Extension of DAkkS calibration at Memmert factory by an additional freely selectable temperature and humidity value according to method C (DKD-R 5-7) (requires option K7) E48848
IQ check list with device-specific works test data as support for validation by customer D00103
OQ check list with device-specific works test data, including temperature distribution survey with 27 temperature measuring points at Memmert factory for a freely selectable temperature value according to DIN12880:2007-05 (PQ check list as support for validation by customer) D00104
OQ check list with device-specific works test data, including temperature distribution survey with 27 temperature measuring points and 1 humidity measuring point in centre of usable space at Memmert factory for a freely selectable temperature and humidity value according to DIN12880:2007-05 (PQ check list as support for validation by customer) (only CTC) D00144
IQ document with device-specific works test data, OQ/PQ check list as support for validation by customer D00124
IQ/OQ document with device-specific works test data, including temperature distribution survey with 5 temperature measuring points and 1 pressure measuring point each thermoshelf at Memmert factory for a freely selectable temperature and pressure value according to DIN12880:2007-05 (PQ check list as support for validation by customer), valid for one thermoshel, price for every further thermoshelf on request D00117
Extension of IQ/OQ document at Memmert factory by an additional freely selectable temperature and pressure value D49126
IQ document with device-specific works test data, OQ/PQ check list as support for validation by customer D00124
IQ/OQ document with device-specific works test data, including temperature distribution survey with 9 temperature measuring points (size 30) and 27 temperature measuring points (sizes 55 - 1060) at Memmert factory for a freely selectable temperature value according to DIN12880:2007-05 (PQ check list as support for validation by customer) D00127 D00125
IQ/OQ document with device-specific works test data, including temperature distribution survey with 27 temperature measuring points (sizes 110 - 1060, 2200) and 26 temperature measuring points (size 1400) at Memmert factory for a freely selectable temperature value according to DIN12880:2007-05 (PQ check list as support for validation by customer) D00127
IQ/OQ document with device-specific works test data, including temperature distribution survey with 9 temperature measuring points (size 30), 27 temperature measuring points (sizes 55 - 1060, 2200) and 26 temperature measuring points (size 1400) at Memmert factory for a freely selectable temperature value according to DIN12880:2007-05 (PQ check list as support for validation by customer) D00125 D00127
IQ/OQ document with device-specific works test data, including temperature distribution survey with 27 temperature measuring points at Memmert factory for a freely selectable temperature value according to DIN12880:2007-05 (PQ check list as support for validation by customer) D00127
IQ/OQ document with device-specific works test data, including temperature distribution survey with 27 temperature measuring points and 1 humidity measuring point in centre of usable space at Memmert factory for a freely selectable temperature and humidity value according to DIN12880:2007-05 (PQ check list as support for validation by customer) D00136
IQ/OQ document with device-specific works test data, including temperature distribution survey with 27 temperature measuring points, 1 humidity measuring point and 1 CO2 measuring point in centre of usable space at Memmert factory for a freely selectable temperature, humidity and CO2 value according to DIN12880:2007-05 (PQ check list as support for validation by customer) (requires option K7) D38897
IQ/OQ document with device-specific works test data, including temperature distribution survey with 27 temperature measuring points and 1 CO2 measuring point in centre of usable space at Memmert factory for a freely selectable temperature and CO2 value according to DIN12880:2007-05 (PQ check list as support for validation by customer) D38898
IQ/OQ document with device-specific works test data for one free-selectable temperature and humidity value, incl. temperature distribution survey at Memmert for 27 measuring points (26 measuring points on model HPP1400) to DIN 12880:2007-05, PQ check list as support for validation by customer (models HPP and ICH). D00136
IQ/OQ document with device-specific works test data, including temperature distribution survey with 27 temperature measuring points (sizes 110 - 1060, 2200), 26 temperature measuring points (size 1400) and 1 humidity measuring point in centre of usable space at Memmert factory for a freely selectable temperature and humidity value according to DIN12880:2007-05 (PQ check list as support for validation by customer) D00136
IQ/OQ document with device-specific works test data, including temperature distribution survey with 27 temperature measuring points, 1 humidity measuring point and 1 light intensity measuring point in centre of usable space at Memmert factory for a freely selectable temperature, humidity and light intensity value according to DIN12880:2007-05 (PQ check list as support for validation by customer) (model ICHLeco/ICHL) D00137
IQ/OQ document with device-specific works test data for one free-selectable temperature and humidity value, and measuring of light intensity, incl. temperature distribution survey at Memmert for 27 measuring points to DIN 12880:2007-05, PQ check list as support for validation by customer. Price for validation at customer site on demand (GER, AT, CH only) D00137
Calibration at Memmert factory for a freely selectable temperature value D00109
Calibration at Memmert factory for a temperature value: +37 °C D00123
IQ/OQ document with device-specific works test data, including temperature distribution survey with 9 temperature measuring points at Memmert factory for a freely selectable temperature value according to DIN12880:2007-05 (PQ check list as support for validation by customer) D00125
Extension of IQ/OQ document at Memmert factory by an additional freely selectable temperature value D49121
Extension of IQ/OQ document at Memmert factory by an additional freely selectable temperature and humidity value D49122
Extension of IQ/OQ document at Memmert factory by an additional freely selectable temperature and humidity value (requires option K7) D49122
Extension of IQ/OQ document at Memmert factory by an additional freely selectable temperature, humidity and CO2 value (requires option K7) D49123
Extension of IQ/OQ document at Memmert factory by an additional freely selectable temperature and CO2 value D49124
Extension of IQ/OQ document at Memmert factory by an additional freely selectable temperature, humidity and light intensity value D49125
Short training on the handling and use of the device on site (outside Germany price on request) S49128
Calibration on site for a freely selectable temperature value (travel costs are not included yet) S00205
Calibration on site for a freely selectable temperature and humidity value (travel costs are not included yet) S00207
Calibration on site for a freely selectable temperature and humidity value (travel costs are not included yet) (only CTC) S00207
Calibration on site for a freely selectable temperature and pressure value (travel costs are not included yet) S00212
Calibration on site for a freely selectable temperature value (travel costs are not included yet) S00205
Calibration on site for a freely selectable temperature and humidity value (requires option K7) (travel costs are not included yet) S00207
Calibration of one freely selectable temperature and humidity value including CO2 (excluding travel costs, not subject to discount, GER, AT, FR only) S00211
Extension of calibration on site by an additional freely selectable temperature value S00215
Extension of calibration on site by an additional freely selectable temperature value S00215
Extension of calibration on site by an additional freely selectable temperature and humidity value (requires option K7) S00216
Extension of calibration on site by an additional freely selectable temperature, humidity and CO2 value (requires option K7) S00217
Extension of calibration on site by an additional freely selectable temperature and humidity value S00216
Extension of calibration on site by an additional freely selectable temperature and humidity value (only CTC) S00216
Extension of calibration on site by an additional freely selectable temperature and pressure value S00218
DAkkS calibration on site for a freely selectable temperature value according to method C (DKD-R 5-7) (travel costs are not included yet) S00360
DAkkS calibration on site for a freely selectable temperature and humidity value according to method C (DKD-R 5-7) (requires option K7) (travel costs are not included yet) S00365
DAkkS calibration on site for a freely selectable temperature and humidity value according to method C (DKD-R 5-7) (travel costs are not included yet) (only CTC) S00365
DAkkS calibration on site for a freely selectable temperature and humidity value according to method C (DKD-R 5-7) (travel costs are not included yet) S00365
IQ/OQ qualification on site including temperature distribution survey with 9 temperature measuring points (size 30) and 27 temperature measuring points (sizes 55 - 160) for a freely selectable temperature value according to DIN12880:2007-05 (travel costs are not included yet) DLQ100
IQ/OQ qualification on site including temperature distribution survey with 27 temperature measuring points for a freely selectable temperature value according to DIN12880:2007-05 (travel costs are not included yet) DLQ100
IQ/OQ qualification on site including temperature distribution survey with 9 temperature measuring points (size 30), 27 temperature measuring points (sizes 55 - 1060, 2200) and 28 temperature measuring points (size 1400) for a freely selectable temperature value according to DIN12880:2007-05 (travel costs are not included yet) DLQ100
IQ/OQ qualification on site including temperature distribution survey with 9 temperature measuring points (size 30) and 27 temperature measuring points (sizes 55 - 1060) for a freely selectable temperature value according to DIN12880:2007-05 (travel costs are not included yet) DLQ100
OQ requalification on site including temperature distribution survey with 9 temperature measuring points (size 30) and 27 temperature measuring points (sizes 55 - 1060) for a freely selectable temperature value according to DIN12880:2007-05 (travel costs are not included yet) DLQ100R
IQ/OQ qualification on site including temperature distribution survey with 9 temperature measuring points (size 30) and 27 temperature measuring points (sizes 55 - 750) for a freely selectable temperature value according to DIN12880:2007-05 (travel costs are not included yet) DLQ100
IQ/OQ qualification on site including temperature distribution survey with 27 temperature measuring points and 1 humidity measuring point in centre of usable space for a freely selectable temperature and humidity value according to DIN12880:2007-05 (requires option K7) (travel costs are not included yet) DLQ101
IQ/OQ qualification on site including temperature distribution survey with 27 temperature measuring points and 1 humidity measuring point in centre of usable space for a freely selectable temperature and humidity value according to DIN12880:2007-05 (travel costs are not included yet) (only CTC) DLQ101
IQ/OQ qualification on site including temperature distribution survey with 27 temperature measuring points and 1 humidity measuring point in centre of usable space for a freely selectable temperature and humidity value according to DIN12880:2007-05 (travel costs are not included yet) DLQ101
IQ/OQ qualification on site including temperature distribution survey with 27 temperature measuring points (sizes 110 - 1060, 2200), 26 temperature measuring points (size 1400) and 1 humidity measuring point in centre of usable space for a freely selectable temperature and humidity value according to DIN12880:2007-05 (travel costs are not included yet) DLQ101
IQ/OQ qualification on site including temperature distribution survey with 27 temperature measuring points and 1 CO2 measuring point in centre of usable space for a freely selectable temperature and CO2 value according to DIN12880:2007-05 (travel costs are not included yet) DLQ102
IQ/OQ qualification on site including temperature distribution survey with 27 temperature measuring points, 1 humidity measuring point and 1 CO2 measuring point in centre of usable space for a freely selectable temperature, humidity and CO2 value according to DIN12880:2007-05 (requires option K7) (travel costs are not included yet) DLQ103
IQ/OQ qualification on site including temperature distribution survey with 27 temperature measuring points, 1 CO2 measuring point and 1 O2 measuring point in centre of usable space for a freely selectable temperature, CO2 and O2 value according to DIN12880:2007-05 (requires option T6) (travel costs are not included yet) DLQ104
IQ/OQ qualification on site including temperature distribution survey with 27 temperature measuring points, 1 humidity measuring point, 1 CO2 measuring point and 1 O2 measuring point in centre of usable space for a freely selectable temperature, humidity, CO2 and O2 value according to DIN12880:2007-05 (requires option K7 and T6) (travel costs are not included yet) DLQ105
IQ/OQ qualification on site including temperature distribution survey with 5 temperature measuring points and 1 pressure measuring point in centre of usable space for a freely selectable temperature and pressure value according to DIN12880:2007-05 (travel costs are not included yet) DLQ106
OQ requalification on site including temperature distribution survey with 27 temperature measuring points for a freely selectable temperature value according to DIN12880:2007-05 (travel costs are not included yet) DLQ100R
OQ requalification on site including temperature distribution survey with 9 temperature measuring points (size 30), 27 temperature measuring points (sizes 55 - 1060, 2200) and 28 temperature measuring points (size 1400) for a freely selectable temperature value according to DIN12880:2007-05 (travel costs are not included yet) DLQ100R
OQ requalification on site including temperature distribution survey with 9 temperature measuring points (size 30), 27 temperature measuring points (sizes 55 - 1060, 2200) and 26 temperature measuring points (size 1400) for a freely selectable temperature value according to DIN12880:2007-05 (travel costs are not included yet) DLQ100R
OQ requalification on site including temperature distribution survey with 9 temperature measuring points (size 30) and 27 temperature measuring points (sizes 55 - 750) for a freely selectable temperature value according to DIN12880:2007-05 (travel costs are not included yet) DLQ100R
OQ requalification on site including temperature distribution survey with 9 temperature measuring points (size 30) and 27 temperature measuring points (sizes 55 - 160) for a freely selectable temperature value according to DIN12880:2007-05 (travel costs are not included yet) DLQ100R
Maintenance on site WTB according to Memmert maintenance plan (available on request) (travel costs are not included yet) S00321
Maintenance contract on site WTB according to Memmert maintenance plan (available on request), minimum duration 3 years (travel costs are not included yet) S00321J
OQ requalification on site including temperature distribution survey with 27 temperature measuring points and 1 humidity measuring point in centre of usable space for a freely selectable temperature and humidity value according to DIN12880:2007-05 (travel costs are not included yet) DLQ101R
OQ requalification on site including temperature distribution survey with 27 temperature measuring points (sizes 110 - 1060, 2200), 26 temperature measuring points (size 1400) and 1 humidity measuring point in centre of usable space for a freely selectable temperature and humidity value according to DIN12880:2007-05 (travel costs are not included yet) DLQ101R
OQ requalification on site including temperature distribution survey with 27 temperature measuring points and 1 humidity measuring point in centre of usable space for a freely selectable temperature and humidity value according to DIN12880:2007- 05 (requires option K7) (travel costs are not included yet) DLQ101R
OQ requalification on site including temperature distribution survey with 27 temperature measuring points and 1 CO2 measuring point in centre of usable space for a freely selectable temperature and CO2 value according to DIN12880:2007-05 (travel costs are not included yet) DLQ102R
OQ requalification on site including temperature distribution survey with 27 temperature measuring points, 1 humidity measuring point and 1 CO2 measuring point in centre of usable space for a freely selectable temperature, humidity and CO2 value according to DIN12880:2007-05 (requires option K7) (travel costs are not included yet) DLQ103R
OQ requalification on site including temperature distribution survey with 27 temperature measuring points, 1 CO2 measuring point and 1 O2 measuring point in centre of usable space for a freely selectable temperature, CO2 and O2 value according to DIN12880:2007-05 (requires option T6) (travel costs are not included yet) DLQ104R
OQ requalification on site including temperature distribution survey with 27 temperature measuring points, 1 humidity measuring point, 1 CO2 measuring point and 1 O2 measuring point in centre of usable space for a freely selectable temperature, humidity, CO2 and O2 value according to DIN12880:2007-05 (requires option K7 and T6) (travel costs are not included yet) DLQ105R
OQ requalification on site including temperature distribution survey with 5 temperature measuring points and 1 pressure measuring point in centre of usable space for a freely selectable temperature and pressure value according to DIN12880:2007-05 (travel costs are not included yet) DLQ106R
OQ requalification on site including temperature distribution survey with 27 temperature measuring points and 1 humidity measuring point in centre of usable space for a freely selectable temperature and humidity value according to DIN12880:2007-05 (travel costs are not included yet) (only CTC) DLQ101R
Extension of IQ/OQ qualification or OQ requalification on site by an additional freely selectable temperature value DLQ100A
Extension of IQ/OQ qualification or OQ requalification on site by an additional freely selectable temperature and humidity value DLQ101A
Extension of IQ/OQ qualification or OQ requalification on site by an additional freely selectable temperature and humidity value (requires option K7) DLQ101A
Extension of IQ/OQ qualification or OQ requalification on site by an additional freely selectable temperature and humidity value (only CTC) DLQ101A
Extension of IQ/OQ qualification or OQ requalification on site by an additional freely selectable temperature and pressure value (each thermoshelf) DLQ106A
Extension of IQ/OQ qualification or OQ requalification on site by a further thermoshelf for a freely selectable temperature and pressure value DLQ106T
Extension of IQ/OQ qualification or OQ requalification on site by an additional freely selectable temperature and CO2 value DLQ102A
Extension of IQ/OQ qualification or OQ requalification on site by an additional freely selectable temperature, humidity and CO2 value (requires option K7) DLQ103A
Extension of IQ/OQ qualification or OQ requalification on site by an additional freely selectable temperature, CO2 and O2 value (requires option T6) DLQ104A
Extension of IQ/OQ qualification or OQ requalification on site by an additional freely selectable temperature, humidity, CO2 and O2 value (requires option K7 and T6) DLQ105A
PQ qualification on site (travel costs are not included yet) DLQ200
PQ qualification on site (travel costs are not included yet) DLQ200
Maintenance on site ICO/ ICOmed active humidity according to Memmert maintenance plan (available on request) (requires option K7) (travel costs are not included yet) S00312
Maintenance on site IPP/ IPPeco according to Memmert maintenance plan (available on request) (travel costs are not included yet) S00317
Maintenance contract on site IPP/ IPPeco according to Memmert maintenance plan (available on request), minimum duration 3 years (travel costs are not included yet) S00317J
Maintenance on site VO according to Memmert maintenance plan (available on request) (travel costs are not included yet) S00320
Maintenance contract on site VO according to Memmert maintenance plan (available on request), minimum duration 3 years (travel costs are not included yet) S00320J
Maintenance on site UIS according to Memmert maintenance plan (available on request) (travel costs are not included yet) S00311
Maintenance contract on site UIS according to Memmert maintenance plan (available on request), minimum duration 3 years (travel costs are not included yet) S00311J
Maintenance on site „Basic“ according to Memmert maintenance plan (available on request) (travel costs are not included yet) S00400
Maintenance on site „Medium“ according to Memmert maintenance plan (available on request) (travel costs are not included yet) S00401
Maintenance on site „Premium“ according to Memmert maintenance plan (available on request) (travel costs are not included yet) S00402
Maintenance on site HPPeco according to Memmert maintenance plan (available on request) (travel costs are not included yet) S00314
Maintenance contract on site HPPeco according to Memmert maintenance plan (available on request), minimum duration 3 years (travel costs are not included yet) S00314J
Maintenance on site HCP according to Memmert maintenance plan (available on request) (travel costs are not included yet) S00313
Maintenance contract on site HCP according to Memmert maintenance plan (available on request), minimum duration 3 years (travel costs are not included yet) S00313J
Maintenance on site ICH/ ICHeco according to Memmert maintenance plan (available on request) (travel costs are not included yet) S00322
Maintenance contract on site ICH/ ICHeco according to Memmert maintenance plan (available on request), minimum duration 3 years (travel costs are not included yet) S00322J
Maintenance on site ICO/ ICOmed passive humidity according to Memmert maintenance plan (available on request) (travel costs are not included yet) S00323
Maintenance contract on site ICO/ ICOmed active humidity according to Memmert maintenance plan (available on request), minimum duration 3 years (requires option K7) (travel costs are not included yet) S00312J
Maintenance contract on site ICO/ ICOmed passive humidity according to Memmert maintenance plan (available on request), minimum duration 3 years (travel costs are not included yet) S00323J
Maintenance on site ICP/ ICPeco according to Memmert maintenance plan (available on request) (travel costs are not included yet) S00315
Maintenance contract on site ICP/ ICPeco according to Memmert maintenance plan (available on request), minimum duration 3 years (travel costs are not included yet) S00315J

Accessories Order No.
Vacuum pump with chemically resistant 4x diaphragm, pump capacity at atm. pressures: approx. 50 Nl./min = 3,0 m3/h and autom. purge control. Order No. B39410 and B04026 necessary. 230 V, 50 Hz. Max. guarantee period 2 years E07509
Chemically resistant vacuum pump with PTFE double diaphragm, pump capacity at atm. pressures: approx. 34 Nl./min = 2,04 m³/h and autom. purge control from vacuum oven. Order No. B04027 and B04026 necessary. 230 V, 50/60 Hz. Max. guarantee period 2 years Chemically resistant vacuum pump with PTFE double diaphragm, pump capacity at atm. pressures: approx. 34 Nl./min = 2,04 m³/h and autom. purge control from vacuum oven. Order No. B04027 and B04026 necessary. 230 V, 50/60 Hz. Max. guarantee period 2 years
Chemically resistant vacuum pump with PTFE double diaphragm, pump capacity at atm. pressures: approx. 60 Nl./min = 3,6 m³/h and autom. purge control from vacuum oven. Order No. B04027 and B04026 necessary. 230 V, 50/60 Hz. Max. guarantee period 2 years Chemically resistant vacuum pump with PTFE double diaphragm, pump capacity at atm. pressures: approx. 60 Nl./min = 3,6 m³/h and autom. purge control from vacuum oven. Order No. B04027 and B04026 necessary. 230 V, 50/60 Hz. Max. guarantee period 2 years
Guarantee extension by 1 year (VO only)
Guarantee extension by 1 year (VOcool only)
Stainless steel gable cover Stainless steel gable cover B50775 B50763 B50764
Flat stainless steel cover with openings and concentric ring sets; 3 openings, Ø 87 mm Flat stainless steel cover with openings and concentric ring sets; 3 openings, Ø 87 mm B48804
Flat stainless steel cover with openings and concentric ring sets; 6 openings, Ø 107 mm Flat stainless steel cover with openings and concentric ring sets; 6 openings, Ø 107 mm B48805
Flat stainless steel cover with concentric ring sets for ring set openings: 8 openings / 107 mm diameter Flat stainless steel cover with concentric ring sets for ring set openings: 8 openings / 107 mm diameter B02684 B48806
Special flat stainless steel cover with openings and concentric ring sets; 3 openings, Ø 87 mm (only in combination with CPM650) Special flat stainless steel cover with openings and concentric ring sets; 3 openings, Ø 87 mm (only in combination with CPM650) B48807
Special flat stainless steel cover with openings and concentric ring sets; 6 openings, Ø 107 mm (only in combination with CPM650) Special flat stainless steel cover with openings and concentric ring sets; 6 openings, Ø 107 mm (only in combination with CPM650) B48808
Special flat stainless steel cover with openings and concentric ring sets; 8 openings, Ø 107 mm (only in combination with CPM650) Special flat stainless steel cover with openings and concentric ring sets; 8 openings, Ø 107 mm (only in combination with CPM650) B48809
Perforated bottom shelf, reversible for 2 heights (30 or 60 mm), stainless steel Perforated bottom shelf, reversible for 2 heights (30 or 60 mm), stainless steel E02893 E02894 E02895 E02896 B50767 B50769 B50771
Installation and connection set for Peltier cooling device CDP115 (incl. mounting bars for all different bath sizes) B02770
Pump device for continuous circulation of the tempering medium. Voltage 230 V, 50/60 Hz. Please do not forget to order the installation and connection set (B48813)! Pump device for continuous circulation of the tempering medium. Voltage 230 V, 50/60 Hz. Please do not forget to order the installation and connection set (B48813)! CPM650
Installation and connection set for pump device CPM650 (incl. mounting bars for all different bath sizes) B48813
Shaking device for water baths incl. support frame, shaking frequency 30 - 150 strokes per minute (horizontal back/forth movement), requires special gable cover. Voltage 230 V, 50/60 Hz. Please do not forget to order the support basket. Shaking device for water baths incl. support frame, shaking frequency 30 - 150 strokes per minute (horizontal back/forth movement), requires special gable cover. Voltage 230 V, 50/60 Hz. Please do not forget to order the support basket. SV1524 SV3550
Shaking device for water baths incl. support frame, shaking frequency 30 - 150 strokes per minute (horizontal back/forth movement), requires special gable cover. Voltage 115 V, 60 Hz. Please do not forget to order the support basket. Shaking device for water baths incl. support frame, shaking frequency 30 - 150 strokes per minute (horizontal back/forth movement), requires special gable cover. Voltage 115 V, 60 Hz. Please do not forget to order the support basket. SV1524X2 SV3550X2
Stainless steel gable cover, also suitable for shaking device (14/22 und 29/45) or Peltier cooling unit CDP 115 Stainless steel gable cover, also suitable for shaking device (14/22 und 29/45) or Peltier cooling unit CDP 115 B02641 B02642 B02643 B04390
Flat stainless steel cover with concentric ring sets for ring set openings: 1 opening / 147 mm diameter Flat stainless steel cover with concentric ring sets for ring set openings: 1 opening / 147 mm diameter B02680
Flat stainless steel cover with concentric ring sets for Peltier cooling CDP115: 1 opening / 147 mm diameter Flat stainless steel cover with concentric ring sets for Peltier cooling CDP115: 1 opening / 147 mm diameter B24372
Flat stainless steel cover with concentric ring sets for ring set openings: 3 openings / 107 mm diameter Flat stainless steel cover with concentric ring sets for ring set openings: 3 openings / 107 mm diameter B02681
Flat stainless steel cover with concentric ring sets for Peltier cooling CDP115: 3 openings / 107 mm diameter Flat stainless steel cover with concentric ring sets for Peltier cooling CDP115: 3 openings / 107 mm diameter B24373
Portable stainless steel rack for 10 baby bottles: maximum capacity each bath: size 10: 1 rack, size 14: 2 racks, size 29: 4 racks Portable stainless steel rack for 10 baby bottles: maximum capacity each bath: size 10: 1 rack, size 14: 2 racks, size 29: 4 racks E02066
Flat stainless steel cover with concentric ring sets for ring set openings: 6 openings / 87 mm diameter Flat stainless steel cover with concentric ring sets for ring set openings: 6 openings / 87 mm diameter B02682
Flat stainless steel cover with concentric ring sets for Peltier cooling CDP115: 6 openings / 87 mm diameter Flat stainless steel cover with concentric ring sets for Peltier cooling CDP115: 6 openings / 87 mm diameter B04552
Flat stainless steel cover with concentric ring sets for ring set openings: 4 openings / 147 mm diameter Flat stainless steel cover with concentric ring sets for ring set openings: 4 openings / 147 mm diameter B02685
Flat stainless steel cover with concentric ring sets for Peltier cooling CDP115: 8 openings / 107 mm diameter Flat stainless steel cover with concentric ring sets for Peltier cooling CDP115: 8 openings / 107 mm diameter B04462
Support basket with perforated mounting shelf (stainless steel) with grid perforations to take clips for conical flasks (use of test tube racks not possible) Support basket with perforated mounting shelf (stainless steel) with grid perforations to take clips for conical flasks (use of test tube racks not possible) B48181 B04397 B48814 B48815
Clip for 100 ml flask, max. flasks see sketch on demand Clip for 100 ml flask, max. flasks see sketch on demand B02692
Clip for 200 ml flask, max. flasks see sketch on demand Clip for 200 ml flask, max. flasks see sketch on demand B02693
Clip for 300 ml flask, max. flasks see sketch on demand Clip for 300 ml flask, max. flasks see sketch on demand B02694
Clip for 500 ml flask, max. flasks see sketch on demand Clip for 500 ml flask, max. flasks see sketch on demand B02695
Rack for 171 test tubes 14.5 mm dia. Rack for 171 test tubes 14.5 mm dia. B48816
Rack for 475 test tubes 14.5 mm dia. Rack for 475 test tubes 14.5 mm dia. B48817
Rack for 119 test tubes 18 mm dia. Rack for 119 test tubes 18 mm dia. B48818
Rack for 357 test tubes 18 mm dia. Rack for 357 test tubes 18 mm dia. B48819
Rack for 45 test tubes 32 mm dia. Rack for 45 test tubes 32 mm dia. B48820
Rack for 117 test tubes 32 mm dia. Rack for 117 test tubes 32 mm dia. B48821
Rack for 110 test tubes 14.5 mm dia. Rack for 110 test tubes 14.5 mm dia. B02778
Rack for 216 test tubes 14.5 mm dia. B04399
Rack for 90 test tubes 18 mm dia. Rack for 90 test tubes 18 mm dia. B02779
Rack for 180 test tubes 18 mm dia. B04400
Rack for 25 test tubes 32 mm dia. B02780
Rack for 54 test tubes 32 mm dia. B04401
Test tube racks, holes 2-row racks, 34 holes, Ø 10 mm each (bath capacity 3 racks) Test tube racks, holes 2-row racks, 34 holes, Ø 10 mm each (bath capacity 3 racks) B48822
Test tube racks, holes 2-row racks, 58 holes, Ø 10 mm each (bath capacity 4 racks) Test tube racks, holes 2-row racks, 58 holes, Ø 10 mm each (bath capacity 4 racks) B48823
Test tube racks, holes 2-row racks, 74 holes, Ø 10 mm each (bath capacity 9 racks) Test tube racks, holes 2-row racks, 74 holes, Ø 10 mm each (bath capacity 9 racks) B50656
Test tube racks, holes 2-row racks, 30 holes, Ø 12 mm each (bath capacity 3 racks) Test tube racks, holes 2-row racks, 30 holes, Ø 12 mm each (bath capacity 3 racks) B48824
Test tube racks, holes 2-row racks, 58 holes, Ø 12 mm each (bath capacity 4 racks) Test tube racks, holes 2-row racks, 58 holes, Ø 12 mm each (bath capacity 4 racks) B48825
Test tube racks, holes 2-row racks, 66 holes, Ø 12 mm each (bath capacity 9 racks) Test tube racks, holes 2-row racks, 66 holes, Ø 12 mm each (bath capacity 9 racks) B50657
Test tube racks, holes 2-row racks, 26 holes, Ø 14.5 mm each (bath capacity 2 racks) Test tube racks, holes 2-row racks, 26 holes, Ø 14.5 mm each (bath capacity 2 racks) B48826
Test tube racks, holes 2-row racks, 46 holes, Ø 14.5 mm each (bath capacity 3 racks) Test tube racks, holes 2-row racks, 46 holes, Ø 14.5 mm each (bath capacity 3 racks) B48827
Test tube racks, holes 2-row racks, 58 holes, Ø 14.5 mm each (bath capacity 8 racks) Test tube racks, holes 2-row racks, 58 holes, Ø 14.5 mm each (bath capacity 8 racks) B50658
Test tube racks, holes 2-row racks, 22 holes, Ø 18 mm each (bath capacity 2 racks) Test tube racks, holes 2-row racks, 22 holes, Ø 18 mm each (bath capacity 2 racks) B48828
Test tube racks, holes 2-row racks, 38 holes, Ø 18 mm each (bath capacity 3 racks) Test tube racks, holes 2-row racks, 38 holes, Ø 18 mm each (bath capacity 3 racks) B48829
Test tube racks, holes 2-row racks, 50 holes, Ø 18 mm each (bath capacity 6 racks) Test tube racks, holes 2-row racks, 50 holes, Ø 18 mm each (bath capacity 6 racks) B50659
Test tube racks, holes 2-row racks, 18 holes, Ø 21 mm each (bath capacity 2 racks) Test tube racks, holes 2-row racks, 18 holes, Ø 21 mm each (bath capacity 2 racks) B48830
Test tube racks, holes 2-row racks, 34 holes, Ø 21 mm each (bath capacity 3 racks) Test tube racks, holes 2-row racks, 34 holes, Ø 21 mm each (bath capacity 3 racks) B48831
Test tube racks, holes 2-row racks, 44 holes, Ø 21 mm each (bath capacity 6 racks) Test tube racks, holes 2-row racks, 44 holes, Ø 21 mm each (bath capacity 6 racks) B50660
Test tube racks, holes 2-row racks, 14 holes, Ø 32 mm each (bath capacity 1 rack) Test tube racks, holes 2-row racks, 14 holes, Ø 32 mm each (bath capacity 1 rack) B48832
Test tube racks, holes 2-row racks, 22 holes, Ø 32 mm each (bath capacity 2 racks) Test tube racks, holes 2-row racks, 22 holes, Ø 32 mm each (bath capacity 2 racks) B48833
Test tube racks, holes 2-row racks, 30 holes, Ø 32 mm each (bath capacity 4 racks) Test tube racks, holes 2-row racks, 30 holes, Ø 32 mm each (bath capacity 4 racks) B50661
Test tube racks, holes 3- row racks, 33 holes, Ø 18 mm each (bath capacity 1 rack) Test tube racks, holes 3- row racks, 33 holes, Ø 18 mm each (bath capacity 1 rack) B48834
Test tube racks, holes 3- row racks, 57 holes, Ø 18 mm each (bath capacity 2 racks) Test tube racks, holes 3- row racks, 57 holes, Ø 18 mm each (bath capacity 2 racks) B48835
Test tube racks, holes 3- row racks, 75 holes, Ø 18 mm each (bath capacity 4 racks) Test tube racks, holes 3- row racks, 75 holes, Ø 18 mm each (bath capacity 4 racks) B50662
Test tube racks, holes 4-row racks, 44 holes, Ø 18 mm each (bath capacity 1 rack) Test tube racks, holes 4-row racks, 44 holes, Ø 18 mm each (bath capacity 1 rack) B48836
Test tube racks, holes 4-row racks, 76 holes, Ø 18 mm each (bath capacity 1 rack) Test tube racks, holes 4-row racks, 76 holes, Ø 18 mm each (bath capacity 1 rack) B48837
Test tube racks, holes 4-row racks, 100 holes, Ø 18 mm each (bath capacity 3 racks) Test tube racks, holes 4-row racks, 100 holes, Ø 18 mm each (bath capacity 3 racks) B50663
Peltier cooling device CDP115 for water baths for temperatures below ambient from +10 °C, Voltage 230 V, 50/60 Hz, or 115 V, 60 Hz (please state in case of order). 
Please do not forget to order the installation and connection set! Peltier cooling device CDP115 for water baths for temperatures below ambient from +10 °C, Voltage 230 V, 50/60 Hz, or 115 V, 60 Hz (please state in case of order). Please do not forget to order the installation and connection set! CDP115
Shaking device incl. support frame, shaking frequency 35 – 160 strokes per minute (horizontal back/forth movement), requires gable cover Shaking device incl. support frame, shaking frequency 35 – 160 strokes per minute (horizontal back/forth movement), requires gable cover SV1422 SV2945
Additional thermoshelves – aluminium eloxadised material W.-St. 3.3547 (ASTM B209) with integrated large-area heating including local temperature sensing (Pt100, 4-wire-circuit), individual overtemp. protection for each shelf MLOP (Multi-Level-Overtemperature-Control) and calibration certificate B00741 B00743 B00744
Additional thermoshelves – stainless steel material 1.4404 (ASTM 316 L) for especially corrosive material with integrated large-area heating including local temperature sensing (Pt100, 4-wire-circuit), individual overtemp. protection for each shelf MLOP (Multi-Level-Overtemperature-Control) and calibration certificate Additional thermoshelves – stainless steel material 1.4404 (ASTM 316 L) for especially corrosive material with integrated large-area heating including local temperature sensing (Pt100, 4-wire-circuit), individual overtemp. protection for each shelf MLOP (Multi-Level-Overtemperature-Control) and calibration certificate B00733 B00734 B00735
Subframe, tubular steel, black enamelled (for stacking unit consisting of vacuum oven and pump module, total height: 1650 mm, see "further data" and sketch of oven dimensions) E02030 E02031 E02037
Stainless steel grids, electropolished (standard equipment); additional special grid on demand Stainless steel grids, electropolished (standard equipment); additional special grid on demand
Stainless steel grid, electropolished E20165 E28891 E20182
Additional reinforced stainless steel grid, electropolished, max. loading 60 kg; with guide bars and fixing screws (only in connection with option K1). Please consider max. loading of chamber B32190
Stainless steel grids, electropolished Stainless steel grids, electropolished E28884 E20164 E20165 E28891 E20182 B41251 B38955
Reinforced stainless steel grid, electropolished, max. loading 60 kg; from size 450 with guide bars and fixing screws (only in connection with option K1). Please consider max. loading of chamber E29767 E29766 B32190 B32550
Reinforced stainless steel grid, max. loading 60 kg (size 750 with guide bars and fixing screws and only in connection with option K1). Please consider max. loading of chamber. E29767 E29766 B32190 B32550
Reinforced stainless steel grid, electropolished, max. loading 60 kg (model 750 with guide bars and fixing screws and only in connection with option K1) Please consider max. loading of chamber E29767 E29766 B32190 B32550
Reinforced stainless steel grid, electropolished, max. loading 60 kg. Please consider max. loading of chamber E29767 E29766 B32550
Perforated stainless steel shelf E35160 E37418 E35158
Stainless steel grid, electropolished Stainless steel grid, electropolished E20591 E20164 E20165 E43118
Software conforming to FDA ”Celsius FDA Edition“. Meets the requirements for the use of electronically stored data sets and electronic signatures as laid down in Regulation 21 CFR Part 11 of the US Food and Drug Administration (FDA). Base licence for the control of one unit E05019
Integration of additional units (up to max.15 units) into an already existent FDA-software licence (E05019) FDAQ4
Reinforced stainless steel grid, max. loading 60 kg (only in connection with option K1) E20183 E20185
Additional stainless steel grid, full width Additional stainless steel grid, full width
Stainless steel grid E20167 E20182
Perforated stainless steel shelf Perforated stainless steel shelf B29727 B03916 B00325 B29725 B00328 B00326
Reinforced stainless steel shelf, max. loading 60 kg. Please consider max. loading of chamber B32549
Perforated stainless steel shelves B00325 B29725 B00328
Reinforced perforated stainless steel shelves, max. loading 60 kg, with guide bars and fixing screws and only in connection with option K1. Please consider max. loading of chamber Reinforced perforated stainless steel shelves, max. loading 60 kg, with guide bars and fixing screws and only in connection with option K1. Please consider max. loading of chamber B32191 B32549 b32191
Reinforced perforated stainless steel shelf, max. loading 60 kg, with guide bars and fixing screws and only in connection with option K1) Reinforced perforated stainless steel shelf, max. loading 60 kg, with guide bars and fixing screws and only in connection with option K1) B32191 B32549
Additional perforated stainless steel shelf, full width Additional perforated stainless steel shelf, full width
Additional perforated stainless steel shelve, half width
Stainless steel slide-in drip tray, 15 mm rim (may affect the temperature distribution) Stainless steel slide-in drip tray, 15 mm rim (may affect the temperature distribution) E02070 E02072 E02073 E29726 E02075 B32599
Stainless steel slide-in drip tray, 15 mm rim (may affect the temperature distribution) - cannot be used in connection with option K1 E02070 E02072 E02073 E29726 E02075 B32599 E02068 B29726
Stainless steel slide-in drip tray, 15 mm rim, with guide bars and fixing screws (may affect the temperature distribution) - can be used only in connection with option K1 B32763
Max. loading per slide-in drip tray (kg) 1,5 3 4 8 5
Stainless steel bottom drip tray, 15 mm rim (may affect the temperature distribution) Stainless steel bottom drip tray, 15 mm rim (may affect the temperature distribution) B04356 B04358 B04359 B29722 B04362 B29769
Stainless steel bottom drip tray, 15 mm rim (may affect the temperature distribution) - cannot be used in connection with option K1 B04356 B04358 B04359 B29722 B04362 B29769 B04360
Stainless steel bottom drip tray, 15 mm rim (may affect the temperature distribution) - can be used only in connection with option K1 B34055
Max. loading per bottom drip tray (kg) 1,5 3 4 8 5
External control and logging package consisting of mini-Notebook and software „Celsius“, pre-configurated, and lateral swinging arm B04410
Removable bottom drip tray – stainless steel material 1.4404 (ASTM 316 L)
Holder for water tank (sizes 110 - 750: 2.5 litres, sizes 1060/1400/2200: 10 litres) for mounting on the rear of the appliance. Standard equipment for sizes 410, 750, 1060, 1400 and 2200. E32172 B49092
Holder for water tank (2.5 litres) for mounting on the rear of the appliance. Standard equipment for size 750 E32172
Water dish B38737
Central water supply with filter cartridges for connection to the domestic water supply. Product information on demand. ZWVR6 ZVWR6
Central water supply without filter cartridges for connection to the domestic water supply (only for demineralised water with a conductivity of 5 to 10 μS/cm and a pH value between 5 and 7). Product information on demand ZWVR7
Central water supply with filter cartridges for connection to the domestic water supply, only in combination with option K7. Product information on demand ZWVR6
Central water supply, without filter cartridges for connection to the domestic water supply (only for demineralised water with a conductivity of 5 to 10 μS/cm and a pH value between 5 and 7) only in combination with option K7. Product information on demand ZWVR7 ZWFR7
Max. loading per slide-in drip tray (kg) 3 4 8 1,5
Max. loading per bottom drip tray (kg) 3 4 8 1,5
Wall bracket for wall mounting Wall bracket for wall mounting B29755 B29756 B29757 B29758 B29759
HEPA14-filter for chamber according to EN 1822, packed in sterile condition, incl. fixing unit B49800
3 HEPA14-filters (B49800) for chamber according to EN 1822, packed in sterile condition, incl. fixing unit B39698
Flush-fit unit set (stainless steel frame covering gap between oven and wall opening), without air slots - technical clarification required B33204 B33205 B33206 B33207
Noise-insulated vacuum pump module without pump (exterior dimensions and -material No. s. vacuum oven) with antivibration metal plate at the bottom to accommodate the vacuum pump, incl. full-sight glass door. Socket, signal cable and connecting hose to the vacuum oven PM29 PM49 PM101
Noise-insulated vacuum pump module without pump (exterior dimensions and material No. see vacuum oven) with antivibration metal plate at the bottom to accommodate the vacuum pump, incl. full-sight glass door. Socket, signal cable and connecting hose to the vacuum oven Noise-insulated vacuum pump module without pump (exterior dimensions and material No. see vacuum oven) with antivibration metal plate at the bottom to accommodate the vacuum pump, incl. full-sight glass door. Socket, signal cable and connecting hose to the vacuum oven
Noise-insulated vacuum pump module, as above, however with built-in pump, 230 V, 50/60 Hz (pump B04133 for VO 200 and pump B04134 for VO 400 and 500) Noise-insulated vacuum pump module, as above, however with built-in pump, 230 V, 50/60 Hz (pump B04133 for VO 200 and pump B04134 for VO 400 and 500)
Noise-insulated vacuum pump module, as above, however with built-in pump, 230 V, 50/60 Hz PMP29 PMP49 PMP101 PMP 29 PMP 49
Signal cable (3 m) for optimising pump performance by demand-controlled activation of purge of Memmert pump
Signal cable (3 m) for control of roation speed and optimising pump performance by demand-controlled activation of purge of Memmert pump (not required with pump module) B39410
Vacuum connecting hose (3 m) from oven to Memmert pump incl. optimised connection accessories (partially stainless steel), (not required with pump module) Vacuum connecting hose (3 m) from oven to Memmert pump incl. optimised connection accessories (partially stainless steel), (not required with pump module) B04026
USB-Ethernet adapter E06192
Ethernet connection cable 5 m for computer interface E06189
Ethernet connection cable 5 m for computer interface E06189
Ethernet connection cable 5 m for computer interface E06189
USB User-ID stick (with User-ID licence): Oven-linked authorisation licence (User-ID-programme) on Memory-stick, prevents undesired manipulation by unauthorised third parties. When reordering please specify serial number B33170
USB User-ID stick (with User-ID licence): Oven-linked authorisation licence (User-ID-programme) on Memory-stick, prevents undesired manipulation by unauthorised third parties. When reordering please specify serial number (only for units with TwinDISPLAY) B33170
USB stick with documentation software AtmoCONTROL and operation manual for products with SingleDISPLAY (the standard equipment of appliances with TwinDISPLAY includes one USB stick with AtmoCONTROL) USB stick with documentation software AtmoCONTROL and operation manual for products with SingleDISPLAY (the standard equipment of appliances with TwinDISPLAY includes one USB stick with AtmoCONTROL). When reordering please specify serial number B33172
USB stick with documentation software AtmoCONTROL and operation manual. When reordering please specify serial number B33172
Set of height adjustable feet (4 pcs) B29768
Set of height adjustable feet (4 pcs) B29768
Stacking set (4 pcs) for stacking of appliances of same size Stacking set (4 pcs) for stacking of appliances of same size B29744
Stacking set (consisting of stacking corners, one connecting plate for the rear, two wall brackets) for stacking of two units of same size B42114
Stacking set (consisting of stacking corners, one connecting plate for the rear, two wall brackets) for stacking of two units of same size (size 240 only in combination with subframe B33509 or B43598) B48129 B42114
Plug-in tube extension (outer diam. 60,3 mm, inner 57 mm), straight, for exhaust air ducting (if necessary for connection by hose) Plug-in tube extension (outer diam. 60,3 mm, inner 57 mm), straight, for exhaust air ducting (if necessary for connection by hose) B29718
Plug-in tube extension (outer diam. 60,3 mm, inner 57 mm), angled, for exhaust air ducting (if necessary for connection by hose), only models U, I, S Plug-in tube extension (outer diam. 60,3 mm, inner 57 mm), angled, for exhaust air ducting (if necessary for connection by hose), only models U, I, S B29719
Loading set consisting of 8 grids, as well as 6 spacers - incl. 3 baskets for cups/glasses, made of stainless steel material no. 1.4301 (ASTM 304) B51799
Flush-fit unit (stainless steel frame covering gap between oven and wall opening) – technical clarification necessary B03190 B03188
Flush-fit unit (stainless steel frame covering gap between oven and wall opening), with air slots – technical clarification required Flush-fit unit (stainless steel frame covering gap between oven and wall opening), with air slots – technical clarification required B29728 B42116 B29742 B29743 B29738 B29740 B29730 B29734 B29736 B29732
Flush-fit unit (stainless steel frame covering gap between oven and wall opening), without air slots – technical clarification required Flush-fit unit (stainless steel frame covering gap between oven and wall opening), without air slots – technical clarification required B29729 B42117 B29743 B29735 B29739 B29741 B29731 B29737 B29733 B41227
Additional water dish (half width model 246) Additional water dish (half width model 246)
Subframe (622 mm high) adjustable in height (sizes 150/240: should not be used for 2 stacked units) B33504 B33505 B33506
Subframe (130 mm high); sizes 150/240: only in combination with the corresponding stacking sets for stacked appliances. B33507 B33508 B33509
Subframe, tubular steel, black enamelled (for stacking unit consisting of vacuum oven and pump module, total height: 1650 mm) Width/ Height/ Depth: model 200: 529/450/383, model 400: 529/290/463, model 500: 689/130/533 Subframe, tubular steel, black enamelled (for stacking unit consisting of vacuum oven and pump module, total height: 1650 mm) Width/ Height/ Depth: model 200: 529/450/383, model 400: 529/290/463, model 500: 689/130/533
Subframe, tubular steel, black enamelled (for stacking unit consisting of vacuum oven and pump module, total height: 1650 mm) Width/ Height/ Depth: model 200: 529/450/383, model 400: 529/290/463 Subframe, tubular steel, black enamelled (for stacking unit consisting of vacuum oven and pump module, total height: 1650 mm) Width/ Height/ Depth: model 200: 529/450/383, model 400: 529/290/463
Subframe, adjustable in height (622 mm high) Subframe, adjustable in height (622 mm high)
Subframe, (130 mm high for 2 stacked cabinets)
Subframe (622 mm high) Subframe (622 mm high)
Subframe (130 mm hight for 2 stacked incubators)
Subframe, adjustable in height (size 30 to 75: height 600 mm, size 110 to 450: height 500 mm) Subframe, adjustable in height (size 30 to 75: height 600 mm, size 110 to 450: height 500 mm) B29745 B29749 B29751 B29747 B29753
Subframe, adjustable in height (height 500 mm) Subframe, adjustable in height (height 500 mm) B29749 B29751 B29753
Subframe, adjustable in height (size 30 and 55: height 600 mm, size 110 and 260: height 500 mm) Subframe, adjustable in height (size 30 and 55: height 600 mm, size 110 and 260: height 500 mm) B29745 B29747 B29749 B29751
Subframe, on castors (size 30 to 75: height 660 mm, size 110 to 160: height 560 mm) Subframe, on castors (size 30 to 75: height 660 mm, size 110 to 160: height 560 mm) B29746 B29750 B29748
Subframe, on castors (height 560 mm) Subframe, on castors (height 560 mm) B29750
Subframe, on castors (size 30 and 55: height 660 mm, size 110: height 560 mm) Subframe, on castors (size 30 and 55: height 660 mm, size 110: height 560 mm) B29746 B29748 B29750
Subframe, adjustable in height, height 130 mm B33657 B33661 B33664 B33659
Subframe, on castors (height 120 mm; stainless steel, material 1.4301) B43598
HEPA-filter for chamber according to EN 1822, packed in sterile condition, incl. fixing unit
CO2 pressure reducing valve DIN 8546, incl. Gas cylinder monitor E02087
N2 pressure reducing valve to DIN EN ISO 2503, incl. gas cylinder monitor (requires option T6) E06162
USB connection cable for computer interface E03643
Additional chip card, blank, formatted (32 kB MEMoryCard XL for a maximum of 40 ramps) E04004
Oven-linked authorisation card (User-ID-Card) prevents undesired manipulation by unauthorised third parties. When reordering please specify serial number E04159
Temperature profile write/read unit for programming via PC, for writing to and reading from the chip card, up to 40 ramps E05284
Test tube rack, holes 3-row racks, 60 holes, dia. 10 mm each, width 50 mm Test tube rack, holes 3-row racks, 60 holes, dia. 10 mm each, width 50 mm E02046
Test tube rack, holes 3-row racks, 60 holes, dia. 12 mm each, width 55 mm Test tube rack, holes 3-row racks, 60 holes, dia. 12 mm each, width 55 mm E02049
Test tube rack, holes 3-row racks, 36 holes, dia. 14.5 mm each, width 60 mm Test tube rack, holes 3-row racks, 36 holes, dia. 14.5 mm each, width 60 mm E02039
Test tube rack, holes 3-row racks, 36 holes, dia. 18 mm each, width 70 mm Test tube rack, holes 3-row racks, 36 holes, dia. 18 mm each, width 70 mm E02019
Test tube rack, holes 3-row racks, 30 holes, dia. 21 mm each, width 80 mm Test tube rack, holes 3-row racks, 30 holes, dia. 21 mm each, width 80 mm E02043
Test tube rack, holes 4-row racks, 80 holes, dia. 10 mm each, width 64 mm Test tube rack, holes 4-row racks, 80 holes, dia. 10 mm each, width 64 mm E02057
Test tube rack, holes 4-row racks, 80 holes, dia. 12 mm each, width 75 mm Test tube rack, holes 4-row racks, 80 holes, dia. 12 mm each, width 75 mm E02060
Test tube rack, holes 4-row racks, 48 holes, dia. 14.5 mm each, width 85 mm Test tube rack, holes 4-row racks, 48 holes, dia. 14.5 mm each, width 85 mm E02056
Test tube rack, holes 4-row racks, 48 holes, dia. 18 mm each, width 95 mm Test tube rack, holes 4-row racks, 48 holes, dia. 18 mm each, width 95 mm E02051
Test tube rack, holes 4-row racks, 40 holes, dia. 21 mm each, width 110 mm Test tube rack, holes 4-row racks, 40 holes, dia. 21 mm each, width 110 mm E02061
Test tube racks, 56 holes (7x8), dia.18 mm each, bath capacity: 1 rack Test tube racks, 56 holes (7x8), dia.18 mm each, bath capacity: 1 rack B02781
Test tube racks, 24 holes (3x8), dia.18 mm each, bath capacity: 2 racks Test tube racks, 24 holes (3x8), dia.18 mm each, bath capacity: 2 racks B02783
Test tube rack, holes 2-row racks, 40 holes, dia. 10 mm each, width 40 mm Test tube rack, holes 2-row racks, 40 holes, dia. 10 mm each, width 40 mm E02028
Test tube rack, holes 2-row racks, 40 holes, dia. 12 mm each, width 40 mm Test tube rack, holes 2-row racks, 40 holes, dia. 12 mm each, width 40 mm E02013
Test tube rack, holes 2-row racks, 24 holes, dia. 14.5 mm each, width 43 mm Test tube rack, holes 2-row racks, 24 holes, dia. 14.5 mm each, width 43 mm E02014
Test tube rack, holes 2-row racks, 24 holes, dia. 18 mm each, width 50 mm Test tube rack, holes 2-row racks, 24 holes, dia. 18 mm each, width 50 mm E02022
Test tube rack, holes 2-row racks, 20 holes, dia. 21 mm each, width 55 mm Test tube rack, holes 2-row racks, 20 holes, dia. 21 mm each, width 55 mm E02032
Test tube rack, holes 2-row racks, 12 holes, dia. 32 mm each, width 80 mm Test tube rack, holes 2-row racks, 12 holes, dia. 32 mm each, width 80 mm E02034
Software conforming to FDA AtmoCONTROL. Meets the requirements for the use of electronically stored data sets and electronic signatures as laid down in Regulation 21 CFR Part 11 of the US Food and Drug Administration (FDA). Base licence for the control of one unit (only for units with TwinDISPLAY). Respective IQ/OQ documents available in German and English language (without surcharge) FDAQ1
External measuring instrument with sensors for daylight and UV-light, with additional measuring head for temperature and humidity. Product information on demand (models HCP and CTC) B04714
External measuring instrument with additional measuring head for temperature and humidity measurement. Product information on demand B04714
Software conforming to FDA AtmoCONTROL. Meets the requirements for the use of electronically stored data sets and electronic signatures as laid down in Regulation 21 CFR Part 11 of the US Food and Drug Administration (FDA). Base licence for the control of one unit (only for units with TwinDISPLAY). Respective IQ/OQ documents available in German and English language (without surcharge) FDAQ1
Software conforming to FDA AtmoCONTROL. Meets the requirements for the use of electronically stored data sets and electronic signatures as laid down in Regulation 21 CFR Part 11 of the US Food and Drug Administration (FDA). Base licence for reading the data logging of one unit (only for units with TwinDISPLAY). Respective IQ/OQ documents available in German and English language (without surcharge) FDAQ1 FADQ1
Integration of one additional unit (up to max. 31 units) into an already existent FDA-software licence FDAQ2
Integration of one additional unit (up to max. 31 units) into an already existent FDA-software licence (only for units with TwinDISPLAY) FDAQ2
External measuring instrument with sensors for daylight and UV-light. Product information on demand (models HPPeco, ICHLeco/ ICHL, IPPecoplus) B04713
External measuring instrument with sensors with additional measuring head for temperature and humidity measurement. Product information on demand (models HPPeco, ICHeco/ICH, ICHLeco/ICHL, IPPecoplus and ICOmed) B04714
IQ/OQ document with works test data for chamber, incl. temperature distribution survey for one free-selectable temperature, humidity and light value. 27 measuring points to DIN 12880:2007-05, PQ check list as support for validation by customer (models HPPeco with light and ICHL)
OQ check list with works test data for one free-selectable temperature value incl. temperature distribution survey for 27 measuring points to DIN 12880:2007-05 as support for validation by customer D00104
OQ check list with works test data for one free-selectable temperature and vacuum value incl. temperature distribution survey for 5 measuring points to DIN 12880:2007-05 as support for validation by customer (VO, VOcool only) valid for one thermoshelf, dito for further thermoshelves VO: EUR 340,– each D00117
OQ check list with works test data for one free-selectable humidity and temperature value incl. temperature distribution survey for 27 measuring points to DIN 12880:2007-05 as support for validation by customer (models HCP and CTC) D00104
OQ check list with works test data for one free-selectable CO2, humidity and temperature value incl. temperature distribution survey for 27 measuring points to DIN 12880:2007-05 as support for validation by customer (models INCOmed) D00104
STERICard (additional or as replacement) for automatic chamber sterilisation cycle (not for sterilising the load!)
STERICard (additional or as replacement) for automatic chamber sterilisation cycle (not for sterilising load)
Module for external fresh water supply, only in combination with humidity module
Loading set consisting of 8 grids,
as well as 16 spacers
- incl. 3 baskets for cups/glasses, made of
stainless steel material no. 1.4301 (ASTM 304) Loading set consisting of 8 grids, as well as 16 spacers - incl. 3 baskets for cups/glasses, made of stainless steel material no. 1.4301 (ASTM 304)

Order No.
Additional reinforced perforated stainless steel shelf, max. loading 60 kg; with guide bars and fixing screws (only in connection with option K1). Please consider max. loading of chamber B32191