Options / Accessories

for Steriliser

Safer than disinfection, hot-air sterilisation of containers and instruments

Option

Model sizes 30 55 75 110 160 260 450 750
Works calibration certificate for one (freely selectable) temperature value according to customer specification D00109 D00109 D00109 D00109 D00109 D00109 D00109 D00109
Voltage 115 V, 50/60 Hz (no extra cost) X2 X2 X2 X2 X2 X2
Full-sight glass door (4 insulating glass). Temperature-range up to max. 250 °C. Full-sight glass door (4 insulating glass). Temperature-range up to max. 250 °C. B0 B0 B0 B0 B0 B0 B0 B0
Interior lighting for observing the load Interior lighting for observing the load R0 R0 R0 R0 R0 R0 R0 R0
Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position left centre/centre Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position left centre/centre F0 F0 F0 F0 F0 F0 F0 F0
Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position left centre top Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position left centre top F1 F1 F1 F1 F1 F1 F1 F1
Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position right centre/centre Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position right centre/centre F2 F2 F2 F2 F2 F2 F2 F2
Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position right centre top Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position right centre top F3 F3 F3 F3 F3 F3 F3 F3
Entry port, 23 mm clear diameter for introducing connections at the side, can be closed by flap in special positions (please, state location) - left Entry port, 23 mm clear diameter for introducing connections at the side, can be closed by flap in special positions (please, state location) - left F4 F4 F4 F4 F4 F4 F4 F4
Entry port, 23 mm clear diameter for introducing connections at the side, can be closed by flap in special positions (please, state location) - right Entry port, 23 mm clear diameter for introducing connections at the side, can be closed by flap in special positions (please, state location) - right F5 F5 F5 F5 F5 F5 F5 F5
Entry port, 23 mm clear diameter for introducing connections, can be closed by flap in special positions (please, state location) - rear Entry port, 23 mm clear diameter for introducing connections, can be closed by flap in special positions (please, state location) - rear F6 F6 F6 F6 F6 F6 F6 F6
Entry port, 14 mm clear diameter, can be closed by flap, in special positions at the back (please, state location) Entry port, 14 mm clear diameter, can be closed by flap, in special positions at the back (please, state location) D6 D6 D6 D6 D6 D6 D6 D6
Entry port, 38 mm clear diameter, can be closed by flap, in special positions at the back (please, state location) Entry port, 38 mm clear diameter, can be closed by flap, in special positions at the back (please, state location) F7 F7 F7 F7 F7 F7 F7 F7
Chamber modification for the application of reinforced perforated stainless steel shelves or stainless steel grids (bearing rails mounted in the working chamber) – includes replacement of 2 standard grids by 2 reinforced grids K1 K1
Extended overtemperature protection for SingleDISPLAY devices by additionally integrated Pt100 sensor for independent temperature monitoring for models SN/SF A6 A6 A6 A6 A6 A6 A6 A6
Fresh-air filter (filtration efficiency 80 %) mounted at the bottom (for SF/SFplus). For model sizes 30 – 260, subframe or subframe on castors obligatory R8 R8 R8 R8 R8 R8 R8 R8
4 – 20 mA current loop interface (0 to +260°C corresponds to 4 – 20 mA) Temperature controller actual value V3 V3 V3 V3 V3 V3 V3 V3
4 – 20 mA current loop interface (0 to +260°C corresponds to 4 – 20 mA) Temperature of a Pt100 sensor positioned flexibly in chamber for external temperature monitoring (max. 1 SingleDISPLAY, max. 3 TwinDISPLAY) V6 V6 V6 V6 V6 V6 V6 V6
Fan speed monitoring with switching off the heating and with alarm in case of failure – optional for SFplus only V4 V4 V4 V4 V4 V4 V4 V4
Works calibration certificate for 3 temperatures: +160°C, +180°C, +250°C. Standard works calibration certificate (measuring point chamber centre) at +160°C D00132 D00132 D00132 D00132 D00132 D00132 D00132 D00132
Door with lock (safety lock), Standard with SN/SF and SNplus/SFplus 450 and 750 Door with lock (safety lock), Standard with SN/SF and SNplus/SFplus 450 and 750 B6 B6 B6 B6 B6 B6 B6 B6
Door hinged on the left B8 B8 B8 B8 B8 B8
Potential-free contact (24 V/2 A) with socket to NAMUR NE 28 for external monitoring (indicates when setpoint is reached) Potential-free contact (24 V/2 A) with socket to NAMUR NE 28 for external monitoring (indicates when setpoint is reached) H5 H5 H5 H5 H5 H5 H5 H5
Potential-free contact for combination error message (e.g. supply failure, sensor fault, fuse) Potential-free contact for combination error message (e.g. supply failure, sensor fault, fuse) H6 H6 H6 H6 H6 H6 H6 H6
Potential-free contact (24 V/2 A) with socket to NAMUR NE 28, for signal generation, controlled by programme segment, for free-selectable functions to be activated (e.g. activation of audible and visual signals, exhaust motors, fans, stirrers, etc. Only for units with TwinDISPLAY; max 2 contacts on 1-phase appliances; max 4 contacts on 3-phase appliances, 2 contacts Potential-free contact (24 V/2 A) with socket to NAMUR NE 28, for signal generation, controlled by programme segment, for free-selectable functions to be activated (e.g. activation of audible and visual signals, exhaust motors, fans, stirrers, etc. Only for units with TwinDISPLAY; max 2 contacts on 1-phase appliances; max 4 contacts on 3-phase appliances, 2 contacts H72 H72 H72 H72 H72 H72 H72 H72
Process-dependent programmable door lock (only for units with TwinDISPLAY) D4 D4 D4 D4 D4 D4 D4 D4
Door-open-recognition (only for units with TwinDISPLAY) V5 V5 V5 V5 V5 V5 V5 V5
Flexible Pt100 for positioning in chamber or in load with socket, 4-pin, according to NAMUR NE 28, for external temperature recording (load temperature) max. 3 sensors Flexible Pt100 for positioning in chamber or in load with socket, 4-pin, according to NAMUR NE 28, for external temperature recording (load temperature) max. 3 sensors H4 H4 H4 H4 H4 H4 H4 H4
Additional Pt100 temperature sensor, positioned flexibly in chamber or load, for local temperature measurement (up to 3 additional sensors are possible). The measured temperature can, if required, be indicated on the display, recorded in the integral ring store, and can be documented via the AtmoCONTROL software. Additional Pt100 temperature sensor, positioned flexibly in chamber or load, for local temperature measurement (up to 3 additional sensors are possible). The measured temperature can, if required, be indicated on the display, recorded in the integral ring store, and can be documented via the AtmoCONTROL software. H8 H8 H8 H8 H8 H8 H8 H8
MobileALERT, notification by SMS in case of any error or alarm of the device. Requires option H6 “floating contact for alarm” C3 C3 C3 C3 C3 C3 C3 C3
Temperature restriction (for models UN/UF/UNplus/UFplus, IN/IF/INplus/IFplus) Temperatures: +60, +70, +80, +95, +100, +120, +160, +180, +200 or +220 °C (Please, indicate upon ordering) A8 A8 A8 A8 A8 A8 A8 A8
Castor frame (2-part), height 140 mm Castor frame (2-part), height 140 mm R9 R9 R9 R9 R9 R9
Potential-free contact (24 V/2 A) with socket to NAMUR NE 28, for signal generation, controlled by programme segment, for a total of 3 freely selectable functions to be activated (e.g. activation of audible and visual signals, exhaust motors, fans, stirrers, etc. (only for units with TwinDISPLAY), max 2 contacts for 1-ph. units, max 4 contacts for 3-ph. units,4 contacts H74 H74

Accessory

Model sizes 30 55 75 110 160 260 450 750
Stainless steel grids, electropolished (standard equipment) Stainless steel grids, electropolished (standard equipment) E28884 E20164 E20164 E20165 E20165 E28891 E20182 E20182
Reinforced stainless steel grid, max. loading 60 kg, from size 450 with guide bars and fixing screws and only in connection with option K1 - - - E29767 E29767 E29766 B32190 B32190
Perforated stainless steel shelf Perforated stainless steel shelf B29727 B03916 B03916 B00325 B00325 B29725 B00328 B00328
Reinforced perforated stainless steel shelves, max. loading 60 kg, with guide bars and fixing screws and only in connection with option K1 Reinforced perforated stainless steel shelves, max. loading 60 kg, with guide bars and fixing screws and only in connection with option K1 - - - - - - B32191 B32191
Max. loading per slide-in drip tray (kg) 1,5 1,5 1,5 3 3 4 8 8
Max. loading per bottom drip tray (kg) 1,5 1,5 1,5 3 3 4 8 8
Wall bracket for wall mounting Wall bracket for wall mounting B29755 B29756 B29757 B29758 B29759 - - -
Stainless steel slide-in drip tray, 15 mm rim (may affect the temperature distribution) - cannot be used in connection with option K1 E02070 E02072 E02072 E02073 E02073 E29726 E02075 E02075
Stainless steel bottom drip tray, 15 mm rim (may affect the temperature distribution) - cannot be used in connection with option K1 B04356 B04358 B04358 B04359 B04359 B29722 B04362 B04362
Guarantee extension by 1 year GA1Q5 GA1Q5 GA1Q5 GA1Q5 GA1Q5 GA2Q5 GA2Q5 GA2Q5
USB-Ethernet adapter E06192 E06192 E06192 E06192 E06192 E06192 E06192 E06192
Ethernet connection cable 5 m for computer interface E06189 E06189 E06189 E06189 E06189 E06189 E06189 E06189
USB User-ID stick (with User-ID licence): Oven-linked authorisation licence (User-ID-programme) on Memory-stick, prevents undesired manipulation by unauthorised third parties. When reordering please specify serial number (only for units with TwinDISPLAY) B33170 B33170 B33170 B33170 B33170 B33170 B33170 B33170
USB stick with documentation software AtmoCONTROL and operation manual for products with SingleDISPLAY (the standard equipment of appliances with TwinDISPLAY includes one USB stick with AtmoCONTROL) B33172 B33172 B33172 B33172 B33172 B33172 B33172 B33172
Set of height adjustable feet (4 pcs). Standard on models ICOmed B29768 B29768 B29768 B29768 B29768 B29768
Stacking set (4 pcs) for stacking of appliances of same size (not for models 160, 260, 450, 750, 1060, ICH110, ICH110L and ICH110C) Stacking set (4 pcs) for stacking of appliances of same size (not for models 160, 260, 450, 750, 1060, ICH110, ICH110L and ICH110C) B29744 B29744 B29744 B29744
Plug-in tube extension (outer diam. 60,3 mm, inner 57 mm), straight, for exhaust air ducting (if necessary for connection by hose), only models U, I, S Plug-in tube extension (outer diam. 60,3 mm, inner 57 mm), straight, for exhaust air ducting (if necessary for connection by hose), only models U, I, S B29718 B29718 B29718 B29718 B29718 B29718 B29718 B29718
Plug-in tube extension (outer diam. 60,3 mm, inner 57 mm), angled, for exhaust air ducting (if necessary for connection by hose), only models U, I, S Plug-in tube extension (outer diam. 60,3 mm, inner 57 mm), angled, for exhaust air ducting (if necessary for connection by hose), only models U, I, S B29719 B29719 B29719 B29719 B29719 B29719 B29719 B29719
Flush-fit unit (stainless steel frame covering gap between oven and wall opening), with air slots – technical clarification required Flush-fit unit (stainless steel frame covering gap between oven and wall opening), with air slots – technical clarification required B29728 B29730 B29732 B29734 B29736 B29738 B29740 B29742
Flush-fit unit (stainless steel frame covering gap between oven and wall opening), without air slots – technical clarification required Flush-fit unit (stainless steel frame covering gap between oven and wall opening), without air slots – technical clarification required B29729 B29731 B29733 B29735 B29737 B29739 B29741 B29743
Subframe, adjustable in height (size 30 to 75: height 600 mm, size 110 to 450: height 500 mm) Subframe, adjustable in height (size 30 to 75: height 600 mm, size 110 to 450: height 500 mm) B29745 B29747 B29747 B29749 B29749 B29751 B29753
Subframe, on castors (size 30 to 75: height 660 mm, size 110 to 160: height 560 mm) Subframe, on castors (size 30 to 75: height 660 mm, size 110 to 160: height 560 mm) B29746 B29748 B29748 B29750 B29750 B29750
Subframe, adjustable in height (height 130 mm, for example for units with fresh-air filter) B33657 B33659 B33659 B33661 B33661 B33664
Software conforming to FDA “AtmoCONTROL“. Meets the requirements for the use of electronically stored data sets and electronic signatures as laid down in Regulation 21 CFR Part 11 of the US Food and Drug Administration (FDA). Base licence for the control of one unit (only for units with TwinDISPLAY). Respective IQ/OQ documents available in German and English language (without surcharge). FDAQ1 FDAQ1 FDAQ1 FDAQ1 FDAQ1 FDAQ1 FDAQ1 FDAQ1
Integration of one additional unit (up to max. 15 units) into an already existent FDA-software licence FDAQ2 FDAQ2 FDAQ2 FDAQ2 FDAQ2 FDAQ2 FDAQ2 FDAQ2
IQ document with device-specific works test data, OQ/PQ check list as support for validation by customer D00124 D00124 D00124 D00124 D00124 D00124 D00124 D00124
IQ/OQ document with works test data for chamber, incl. temperature distribution survey for one free-selectable temperature value. 9 measuring points (size 30), 27 measuring points (sizes 55 - 1060) to DIN 12880:2007-05 (further temperature values on demand), PQ check list as support for validation by customer D00125 D00127 D00127 D00127 D00127 D00127 D00127 D00127
IQ/OQ document with device-specific works test data for one free-selectable temperature and humidity value, incl. temperature distribution survey at Memmert for 27 measuring points (26 measuring points on model HPP1400) to DIN 12880:2007-05, PQ check list as support for validation by customer (models HPP and ICH). D00136 D00136 D00136 D00136
IQ/OQ document with works test data for chamber, incl. temperature distribution survey for one free-selectable temperature, humidity and light value. 27 measuring points to DIN 12880:2007-05, PQ check list as support for validation by customer (models HPP with light and ICH L)
External measuring instrument with sensors for daylight and UV-light. Product information on demand (models HPP, ICH L, IPPplus) B04713 B04713 B04713 B04713 B04713 B04713 B04713 B04713
External measuring instrument with sensors with additional measuring head for temperature and humidity measurement. Product information on demand (models HPP, ICH, ICH L, ICH C, IPPplus and ICOmed) B04714 B04714 B04714 B04714 B04714 B04714 B04714 B04714