Options / Accessories

for Peltier-cooled incubator IPP2200ecoplus

Sets eco standards for cultivation below room temperature: unmatched energy efficiency, best values for heat-up, cool-down and recovery times.

Option

Option Order No.
Entry port, 23 mm clear diameter for introducing connections at the side, can be closed by flap in special positions (please, state location) - left Entry port, 23 mm clear diameter for introducing connections at the side, can be closed by flap in special positions (please, state location) - left F4
Entry port, 23 mm clear diameter for introducing connections at the side, can be closed by flap in special positions (please, state location) - right Entry port, 23 mm clear diameter for introducing connections at the side, can be closed by flap in special positions (please, state location) - right F5
Entry port (silicone), 40 mm clear diameter, moisture tight, can be closed by silicone stopper, standard position rear (not in combination with T7, T8, T9) D8
4 – 20 mA current loop interface (-10 to +80°C corresponds to 4 – 20 mA) Temperature controller actual value V3
Works calibration certificate for one (freely selectable) temperature value according to customer specification D00109
Door with lock (safety lock), three locks (one each door) B63
Potential-free contact for combination error message (e.g. supply failure, sensor fault, fuse) Potential-free contact for combination error message (e.g. supply failure, sensor fault, fuse) H6
Process-dependent programmable door lock, three interlocking systems (one each other) D43
Door-open-recognition, three (one each door) V53
MobileALERT, notification by SMS in case of any error or alarm of the device. Requires option H6 “floating contact for alarm” C3

Accessory

Accessory Order No.
DAkkS calibration for one free-selectable temperature value according to method C (DKD-R 5-7) E39696
DAkkS calibration for further temperature values according to method C (DKD-R 5-7) E39697
Stainless steel grids, electropolished (standard equipment) Stainless steel grids, electropolished (standard equipment) B38955
Guarantee extension by 1 year GA4Q5
USB-Ethernet adapter E06192
Ethernet connection cable 5 m for computer interface E06189
USB User-ID stick (with User-ID licence): Oven-linked authorisation licence (User-ID-programme) on Memory-stick, prevents undesired manipulation by unauthorised third parties. When reordering please specify serial number (only for units with TwinDISPLAY) B33170
USB stick with documentation software AtmoCONTROL and operation manual for products with SingleDISPLAY (the standard equipment of appliances with TwinDISPLAY includes one USB stick with AtmoCONTROL) B33172
Integration of one additional unit (up to max. 31 units) into an already existent FDA-software licence FDAQ2
Software conforming to FDA AtmoCONTROL. Meets the requirements for the use of electronically stored data sets and electronic signatures as laid down in Regulation 21 CFR Part 11 of the US Food and Drug Administration (FDA). Base licence for the control of one unit (only for units with TwinDISPLAY). Respective IQ/OQ documents available in German and English language (without surcharge) FDAQ1
IQ/OQ document with works test data for chamber, incl. temperature distribution survey for one free-selectable temperature value. 9 measuring points (size 30), 27 measuring points (sizes 55 - 1060) to DIN 12880:2007-05 (further temperature values on demand), PQ check list as support for validation by customer D00127
IQ document with device-specific works test data, OQ/PQ check list as support for validation by customer D00124
External measuring instrument with sensors with additional measuring head for temperature and humidity measurement. Product information on demand (models HPP, ICH, ICH L, ICH C, IPPplus and ICOmed) B04714
Individual on-site Performance Qualification (PQ) DLQ200
On-site IQ/OQ for a freely selectable temperature value, including temperature distribution survey for 9 measuring points (size 30), 27 measuring points (sizes 55 - 1060, 2200) and 26 measuring points (size 1400) to DIN 12880: 2007-05 (excluding travel costs, not subject to discount, GER, AT, CH, FR only) DLQ100
Extension of DLQ100 by an additional freely selectable temperature value (not subject to discount) DLQ100A
Maintenance IPP/ IPPeco - carrying out and documentation according to Memmert maintenance plan (excluding travel costs, not subject to discount, GER, AT, CH, FR only) S00317
Maintenance contract IPP/ IPPeco - carrying out and documentation according to Memmert maintenance plan, minimum duration 3 years (excluding travel costs, not subject to discount, GER, AT, CH, FR only) S00317J
Calibration of one freely selectable temperature value (excluding travel costs, not subject to discount, GER, AT, CH, FR only) S00205
Calibration of an additional temperature value (not subject to discount) S00215