Options / Accessories

for Peltier-cooled incubator IPP400plus

Microbiology, zoology, food, cosmetics or pharma industry: the energy-saving cooled incubator with Peltier elements heats up and cools down seamlessly in one system.

Option

Option Order No.
Voltage 115 V, 50/60 Hz (no extra cost) X2
Light module cold white 6,500 K: light strips arranged on the side walls of the interior, 10 strips for model 110, 14 for model 260/400/750, programme-controlled dimming from 0 to 100 % (in 1 % steps), ramp programming in combination with temperature (only with TwinDISPLAY; not in combination with D6, F6, F7) T7
Light module cold white 6,500 Kelvin + warm white 2,700 Kelvin: LED light strips -10 strips for model 110, 14 for model 260/400/750 - (5 resp. 7 alternating cold white light strips and 5 resp. 7 warm white light strips) on the side walls of the interior, programme-controlled dimming from 0 to 100 % (in 1 % steps), ramp programming in combination with temperature (only with TwinDISPLAY; not in combination with D6, F6, F7) T8
Light module warm white 2,700 K: light strips arranged on the side walls of the interior, 10 for model 110, 14 for model 260/400/750, programme-controlled dimming from 0 to 100 % (in 1 % steps), ramp programming in combination with temperature (only with TwinDisplay; not in combination with D6, F6, F7) T9
Interior socket, ampacity 230 V/2.2 A, can be switched off with the On/Off switch, cannot be switched individually, moisture tight IP68 R3
Entry port, 14 mm clear diameter, can be closed by flap, in special positions at the back (please, state location; not in combination with T7, T8, T9) Entry port, 14 mm clear diameter, can be closed by flap, in special positions at the back (please, state location; not in combination with T7, T8, T9) D6
Entry port, 23 mm clear diameter, can be closed by flap in special positions (please, state location; not in combination with T7, T8, T9) – rear Entry port, 23 mm clear diameter, can be closed by flap in special positions (please, state location; not in combination with T7, T8, T9) – rear F6
Entry port, 38 mm clear diameter, can be closed by flap, in special positions at the back (please, state location; not in combination with T7, T8, T9) Entry port, 38 mm clear diameter, can be closed by flap, in special positions at the back (please, state location; not in combination with T7, T8, T9) F7
Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position left centre/centre Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position left centre/centre F0
Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position left centre top Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position left centre top F1
Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position right centre/centre Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position right centre/centre F2
Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position right centre top Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position right centre top F3
Entry port, 23 mm clear diameter for introducing connections at the side, can be closed by flap in special positions (please, state location) - left Entry port, 23 mm clear diameter for introducing connections at the side, can be closed by flap in special positions (please, state location) - left F4
Entry port, 23 mm clear diameter for introducing connections at the side, can be closed by flap in special positions (please, state location) - right Entry port, 23 mm clear diameter for introducing connections at the side, can be closed by flap in special positions (please, state location) - right F5
4 – 20 mA current loop interface (-10 to +80°C corresponds to 4 – 20 mA) Temperature controller actual value V3
4 – 20 mA current loop interface (-10 to +80°C corresponds to 4 – 20 mA) Temperature of a Pt100 sensor positioned flexibly in chamber for external temperature monitoring (max. 1 SingleDISPLAY, max. 3 TwinDISPLAY) V6
Works calibration certificate for one (freely selectable) temperature value according to customer specification D00109
Works calibration certificate for 3 temperatures: +5°C, +37°C, +60°C. Standard works calibration certificate (measuring point chamber centre) at +10°C and +37°C Works calibration certificate for 3 temperatures: +5°C, +37°C, +60°C. Standard works calibration certificate (measuring point chamber centre) at +10°C and +37°C D00129
Door with lock (safety lock), Standard with SN/SF and SNplus/SFplus 450 and 750 Door with lock (safety lock), Standard with SN/SF and SNplus/SFplus 450 and 750 B6
Door hinged on the left B8
Potential-free contact (24 V/2 A) with socket to NAMUR NE 28 for external monitoring (indicates when setpoint is reached) Potential-free contact (24 V/2 A) with socket to NAMUR NE 28 for external monitoring (indicates when setpoint is reached) H5
Potential-free contact for combination error message (e.g. supply failure, sensor fault, fuse) Potential-free contact for combination error message (e.g. supply failure, sensor fault, fuse) H6
Potential-free contact (24 V/2 A) with socket to NAMUR NE 28, for signal generation, controlled by programme segment, for free-selectable functions to be activated (e.g. activation of audible and visual signals, exhaust motors, fans, stirrers, etc. Only for units with TwinDISPLAY; max 2 contacts on 1-phase appliances; max 4 contacts on 3-phase appliances, 2 contacts Potential-free contact (24 V/2 A) with socket to NAMUR NE 28, for signal generation, controlled by programme segment, for free-selectable functions to be activated (e.g. activation of audible and visual signals, exhaust motors, fans, stirrers, etc. Only for units with TwinDISPLAY; max 2 contacts on 1-phase appliances; max 4 contacts on 3-phase appliances, 2 contacts H72
Process-dependent programmable door lock (only for units with TwinDISPLAY) D4
Door-open-recognition (only for units with TwinDISPLAY) V5
Flexible Pt100 for positioning in chamber or in load with socket, 4-pin, according to NAMUR NE 28, for external temperature recording (load temperature) max. 3 sensors Flexible Pt100 for positioning in chamber or in load with socket, 4-pin, according to NAMUR NE 28, for external temperature recording (load temperature) max. 3 sensors H4
MobileALERT, notification by SMS in case of any error or alarm of the device. Requires option H6 “floating contact for alarm” C3
Additional Pt100 temperature sensor, positioned flexibly in chamber or load, for local temperature measurement (up to 2 additional sensors are possible). The measured temperature can, if required, be indicated on the display, recorded in the integral ring store, and can be documented via the AtmoCONTROL software. Additional Pt100 temperature sensor, positioned flexibly in chamber or load, for local temperature measurement (up to 2 additional sensors are possible). The measured temperature can, if required, be indicated on the display, recorded in the integral ring store, and can be documented via the AtmoCONTROL software. H8

Accessory

Accessory Order No.
Stainless steel grids, electropolished (standard equipment) Stainless steel grids, electropolished (standard equipment) E28891
Reinforced stainless steel grid, max. loading 60 kg (size 750 with guide bars and fixing screws and only in connection with option K1) E29766
Perforated stainless steel shelf Perforated stainless steel shelf B29725
Stainless steel slide-in drip tray, 15 mm rim (may affect the temperature distribution) - cannot be used in connection with option K1 E29726
Guarantee extension by 1 year GA2Q5
USB-Ethernet adapter E06192
Ethernet connection cable 5 m for computer interface E06189
Stainless steel bottom drip tray, 15 mm rim (may affect the temperature distribution) - cannot be used in connection with option K1 B29722
USB User-ID stick (with User-ID licence): Oven-linked authorisation licence (User-ID-programme) on Memory-stick, prevents undesired manipulation by unauthorised third parties. When reordering please specify serial number (only for units with TwinDISPLAY) B33170
USB stick with documentation software AtmoCONTROL and operation manual for products with SingleDISPLAY (the standard equipment of appliances with TwinDISPLAY includes one USB stick with AtmoCONTROL) B33172
Flush-fit unit (stainless steel frame covering gap between oven and wall opening), with air slots – technical clarification required Flush-fit unit (stainless steel frame covering gap between oven and wall opening), with air slots – technical clarification required B42116
Flush-fit unit (stainless steel frame covering gap between oven and wall opening), without air slots – technical clarification required Flush-fit unit (stainless steel frame covering gap between oven and wall opening), without air slots – technical clarification required B42117
Software conforming to FDA “AtmoCONTROL“. Meets the requirements for the use of electronically stored data sets and electronic signatures as laid down in Regulation 21 CFR Part 11 of the US Food and Drug Administration (FDA). Base licence for the control of one unit (only for units with TwinDISPLAY). Respective IQ/OQ documents available in German and English language (without surcharge). FDAQ1
Integration of one additional unit (up to max. 15 units) into an already existent FDA-software licence FDAQ2
IQ document with device-specific works test data, OQ/PQ check list as support for validation by customer D00124
IQ/OQ document with works test data for chamber, incl. temperature distribution survey for one free-selectable temperature value. 9 measuring points (size 30), 27 measuring points (sizes 55 - 1060) to DIN 12880:2007-05 (further temperature values on demand), PQ check list as support for validation by customer D00127
External measuring instrument with sensors for daylight and UV-light. Product information on demand (models HPP, ICH L, IPPplus) B04713
External measuring instrument with sensors with additional measuring head for temperature and humidity measurement. Product information on demand (models HPP, ICH, ICH L, ICH C, IPPplus and ICOmed) B04714