Voltage 115 V, 50/60 Hz (no extra cost) |
X2 |
X2 |
X2 |
X2 |
X2 |
X2 |
|
|
|
|
Extended overtemperature protection for SingleDISPLAY devices by additionally integrated Pt100 sensor for independent temperature monitoring for models UN/UF |
A6 |
A6 |
A6 |
A6 |
A6 |
A6 |
A6 |
A6 |
A6 |
|
Full-sight glass door (4 insulating glass). Temperature-range up to max. 250 °C. |
B0 |
B0 |
B0 |
B0 |
B0 |
B0 |
B0 |
B0 |
B0 |
|
Full-sight glass door (4 insulating glass). Temperature-range up to max. 300 °C. |
B1 |
B1 |
B1 |
B1 |
B1 |
B1 |
B1 |
B1 |
B1 |
|
Interior lighting for observing the load |
R0 |
R0 |
R0 |
R0 |
R0 |
R0 |
R0 |
R0 |
R0 |
|
Chamber modification for the application of reinforced perforated stainless steel shelves or stainless steel grids (bearing rails mounted in the working chamber) – includes replacement of 2 standard grids by 2 reinforced grids |
|
|
|
|
|
|
K1 |
K1 |
|
|
Interior socket (can only be ordered with limited temperature-range – max. +70°C - option A8 necessary) current carrying ampacity 230 V, 2.2 A can be switched off with the On/Off switch, cannot be switched individually, moisture tight IP68 |
R3 |
R3 |
R3 |
R3 |
R3 |
R3 |
R3 |
R3 |
R3 |
|
Interior socket (can only be ordered with limited temperature range - max. +70 °C). ampacity 230 V/2.2 A, can be switched on/off via tumbler switch in control panel, moisture tight IP68 (requires option A8) |
R4 |
R4 |
R4 |
R4 |
R4 |
R4 |
R4 |
R4 |
R4 |
|
Interior nearly gastight |
K2 |
K2 |
K2 |
K2 |
K2 |
K2 |
K2 |
K2 |
K2 |
|
Interior nearly gastight with possibility for inlet/outlet through 2 tubes with ball valves |
K3 |
K3 |
K3 |
K3 |
K3 |
K3 |
K3 |
K3 |
K3 |
|
Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position left centre/centre |
F0 |
F0 |
F0 |
F0 |
F0 |
F0 |
F0 |
F0 |
F0 |
|
Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position left centre top |
F1 |
F1 |
F1 |
F1 |
F1 |
F1 |
F1 |
F1 |
F1 |
|
Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position right centre/centre |
F2 |
F2 |
F2 |
F2 |
F2 |
F2 |
F2 |
F2 |
F2 |
|
Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position right centre top |
F3 |
F3 |
F3 |
F3 |
F3 |
F3 |
F3 |
F3 |
F3 |
|
Entry port, 23 mm clear diameter for introducing connections at the side, can be closed by flap in special positions (please, state location) - left |
F4 |
F4 |
F4 |
F4 |
F4 |
F4 |
F4 |
F4 |
F4 |
|
Entry port, 23 mm clear diameter for introducing connections at the side, can be closed by flap in special positions (please, state location) - right |
F5 |
F5 |
F5 |
F5 |
F5 |
F5 |
F5 |
F5 |
F5 |
|
Entry port, 23 mm clear diameter for introducing connections, can be closed by flap in special positions (please, state location) - rear |
F6 |
F6 |
F6 |
F6 |
F6 |
F6 |
F6 |
F6 |
F6 |
|
Entry port, 14 mm clear diameter, can be closed by flap, in special positions at the back (please, state location) |
D6 |
D6 |
D6 |
D6 |
D6 |
D6 |
D6 |
D6 |
D6 |
|
Entry port, 38 mm clear diameter, can be closed by flap, in special positions at the back (please, state location) |
F7 |
F7 |
F7 |
F7 |
F7 |
F7 |
F7 |
F7 |
F7 |
|
Entry port, 57 mm clear diameter, can be closed by flap, in special positions at the back (please, state location; not possible for UF/UFplus/UFm/UFmplus size 30-75) |
F8 |
F8 |
F8 |
F8 |
F8 |
F8 |
F8 |
F8 |
F8 |
|
Entry port, 100 mm clear diameter, can be closed by flap, in special positions at the back (please, state location; not possible for UF/UFplus/UFm/UFmplus size 75) |
|
|
F9 |
F9 |
F9 |
F9 |
F9 |
F9 |
F9 |
|
4 – 20 mA current loop interface (0 to +310°C corresponds to 4 – 20 mA)
Temperature controller actual value |
V3 |
V3 |
V3 |
V3 |
V3 |
V3 |
V3 |
V3 |
V3 |
|
4 – 20 mA current loop interface (0 to +310°C corresponds to 4 – 20 mA)
Temperature of a Pt100 sensor positioned flexibly in chamber for external temperature monitoring
(max. 1 SingleDISPLAY, max. 3 TwinDISPLAY) |
V6 |
V6 |
V6 |
V6 |
V6 |
V6 |
V6 |
V6 |
V6 |
|
Fan speed monitoring with switching off the heating and with alarm in case of failure – optional for UFplus only |
V4 |
V4 |
V4 |
V4 |
V4 |
V4 |
V4 |
V4 |
V4 |
|
Works calibration certificate for 3 temperatures: +100°C, +160°C, +220°C. Standard works calibration certificate (measuring point chamber centre) at +160°C |
D00128 |
D00128 |
D00128 |
D00128 |
D00128 |
D00128 |
D00128 |
D00128 |
D00128 |
|
Works calibration certificate for one (freely selectable) temperature value according to customer specification |
D00109 |
D00109 |
D00109 |
D00109 |
D00109 |
D00109 |
D00109 |
D00109 |
D00109 |
|
Door with lock (safety lock), Standard with SN/SF and SNplus/SFplus 450 and 750 |
B6 |
B6 |
B6 |
B6 |
B6 |
B6 |
B6 |
B6 |
B6 |
|
Door hinged on the left |
B8 |
B8 |
B8 |
B8 |
B8 |
B8 |
|
|
|
|
Potential-free contact (24 V/2 A) with socket to NAMUR NE 28 for external monitoring (indicates when setpoint is reached) |
H5 |
H5 |
H5 |
H5 |
H5 |
H5 |
H5 |
H5 |
H5 |
|
Potential-free contact for combination error message (e.g. supply failure, sensor fault, fuse) |
H6 |
H6 |
H6 |
H6 |
H6 |
H6 |
H6 |
H6 |
H6 |
|
Potential-free contact (24 V/2 A) with socket to NAMUR NE 28, for signal generation, controlled by programme segment, for free-selectable functions to be activated (e.g. activation of audible and visual signals, exhaust motors, fans, stirrers, etc. Only for units with TwinDISPLAY; max 2 contacts on 1-phase appliances; max 4 contacts on 3-phase appliances, 2 contacts |
H72 |
H72 |
H72 |
H72 |
H72 |
H72 |
H72 |
H72 |
H72 |
|
Potential-free contact (24 V/2 A) with socket to NAMUR NE 28, for signal generation, controlled by programme segment, for a total of 3 freely selectable functions to be activated (e.g. activation of audible and visual signals, exhaust motors, fans, stirrers, etc. (only for units with TwinDISPLAY), max 2 contacts for 1-ph. units, max 4 contacts for 3-ph. units,4 contacts |
|
|
|
|
|
|
H74 |
H74 |
H74 |
|
Process-dependent programmable door lock (only for units with TwinDISPLAY) |
D4 |
D4 |
D4 |
D4 |
D4 |
D4 |
D4 |
D4 |
D4 |
|
Door-open-recognition (only for units with TwinDISPLAY) |
V5 |
V5 |
V5 |
V5 |
V5 |
V5 |
V5 |
V5 |
V5 |
|
Flexible Pt100 for positioning in chamber or in load with socket, 4-pin, according to NAMUR NE 28, for external temperature recording (load temperature) max. 3 sensors |
H4 |
H4 |
H4 |
H4 |
H4 |
H4 |
H4 |
H4 |
H4 |
|
Additional Pt100 temperature sensor, positioned flexibly in chamber or load, for local temperature measurement (up to 2 additional sensors are possible). The measured temperature can, if required, be indicated on the display, recorded in the integral ring store, and can be documented via the AtmoCONTROL software. |
H8 |
H8 |
H8 |
H8 |
H8 |
H8 |
H8 |
H8 |
H8 |
|
MobileALERT, notification by SMS in case of any error or alarm of the device. Requires option H6 “floating contact for alarm” |
C3 |
C3 |
C3 |
C3 |
C3 |
C3 |
C3 |
C3 |
C3 |
|
Temperature restriction - Temperatures: +60, +70, +80, +95, +100, +120, +160, +180, +200 or +250 °C (Please, indicate upon ordering) |
A8 |
A8 |
A8 |
A8 |
A8 |
A8 |
A8 |
A8 |
A8 |
|
Fresh-air filter (filtration efficiency 80 %) mounted at the bottom (for UF/UFplus). For model sizes 30 – 260, subframe or subframe on castors obligatory |
R8 |
R8 |
R8 |
R8 |
R8 |
R8 |
R8 |
R8 |
R8 |
|
Castor frame (2-part), height 140 mm |
R9 |
R9 |
R9 |
R9 |
R9 |
R9 |
|
|
|