Options / Accessories

for Universal Oven Um UF75m

Option

Option Order No.
Voltage 115 V, 50/60 Hz (no extra cost) X2
Extended overtemperature protection for SingleDISPLAY devices by additionally integrated Pt100 sensor for independent temperature monitoring for models UN/UF A6
Full-sight glass door (4 insulating glass). Temperature-range up to max. 250 °C. Full-sight glass door (4 insulating glass). Temperature-range up to max. 250 °C. B0
Full-sight glass door (4 insulating glass). Temperature-range up to max. 300 °C. Full-sight glass door (4 insulating glass). Temperature-range up to max. 300 °C. B1
Interior lighting for observing the load Interior lighting for observing the load R0
Interior socket (can only be ordered with limited temperature-range – max. +70°C - option A8 necessary) current carrying ampacity 230 V, 2.2 A can be switched off with the On/Off switch, cannot be switched individually, moisture tight IP68 R3
Interior socket (can only be ordered with limited temperature range - max. +70 °C). ampacity 230 V/2.2 A, can be switched on/off via tumbler switch in control panel, moisture tight IP68 (requires option A8) R4
Interior nearly gastight K2
Interior nearly gastight with possibility for inlet/outlet through 2 tubes with ball valves K3
Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position left centre/centre Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position left centre/centre F0
Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position left centre top Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position left centre top F1
Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position right centre/centre Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position right centre/centre F2
Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position right centre top Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position right centre top F3
Entry port, 23 mm clear diameter for introducing connections at the side, can be closed by flap in special positions (please, state location) - left Entry port, 23 mm clear diameter for introducing connections at the side, can be closed by flap in special positions (please, state location) - left F4
Entry port, 23 mm clear diameter for introducing connections at the side, can be closed by flap in special positions (please, state location) - right Entry port, 23 mm clear diameter for introducing connections at the side, can be closed by flap in special positions (please, state location) - right F5
Entry port, 23 mm clear diameter for introducing connections, can be closed by flap in special positions (please, state location) - rear Entry port, 23 mm clear diameter for introducing connections, can be closed by flap in special positions (please, state location) - rear F6
Entry port, 14 mm clear diameter, can be closed by flap, in special positions at the back (please, state location) Entry port, 14 mm clear diameter, can be closed by flap, in special positions at the back (please, state location) D6
Entry port, 38 mm clear diameter, can be closed by flap, in special positions at the back (please, state location) Entry port, 38 mm clear diameter, can be closed by flap, in special positions at the back (please, state location) F7
Entry port, 57 mm clear diameter, can be closed by flap, in special positions at the back (please, state location; not possible for UF/UFplus/UFm/UFmplus size 30-75) Entry port, 57 mm clear diameter, can be closed by flap, in special positions at the back (please, state location; not possible for UF/UFplus/UFm/UFmplus size 30-75) F8
Entry port, 100 mm clear diameter, can be closed by flap, in special positions at the back (please, state location; not possible for UF/UFplus/UFm/UFmplus size 75) Entry port, 100 mm clear diameter, can be closed by flap, in special positions at the back (please, state location; not possible for UF/UFplus/UFm/UFmplus size 75) F9
4 – 20 mA current loop interface (0 to +310°C corresponds to 4 – 20 mA) Temperature controller actual value V3
4 – 20 mA current loop interface (0 to +310°C corresponds to 4 – 20 mA) Temperature of a Pt100 sensor positioned flexibly in chamber for external temperature monitoring (max. 1 SingleDISPLAY, max. 3 TwinDISPLAY) V6
Fan speed monitoring with switching off the heating and with alarm in case of failure – optional for UFplus only V4
Works calibration certificate for 3 temperatures: +100°C, +160°C, +220°C. Standard works calibration certificate (measuring point chamber centre) at +160°C Works calibration certificate for 3 temperatures: +100°C, +160°C, +220°C. Standard works calibration certificate (measuring point chamber centre) at +160°C D00128
Works calibration certificate for one (freely selectable) temperature value according to customer specification D00109
Door with lock (safety lock), Standard with SN/SF and SNplus/SFplus 450 and 750 Door with lock (safety lock), Standard with SN/SF and SNplus/SFplus 450 and 750 B6
Door hinged on the left B8
Potential-free contact (24 V/2 A) with socket to NAMUR NE 28 for external monitoring (indicates when setpoint is reached) Potential-free contact (24 V/2 A) with socket to NAMUR NE 28 for external monitoring (indicates when setpoint is reached) H5
Potential-free contact for combination error message (e.g. supply failure, sensor fault, fuse) Potential-free contact for combination error message (e.g. supply failure, sensor fault, fuse) H6
Potential-free contact (24 V/2 A) with socket to NAMUR NE 28, for signal generation, controlled by programme segment, for free-selectable functions to be activated (e.g. activation of audible and visual signals, exhaust motors, fans, stirrers, etc. Only for units with TwinDISPLAY; max 2 contacts on 1-phase appliances; max 4 contacts on 3-phase appliances, 2 contacts Potential-free contact (24 V/2 A) with socket to NAMUR NE 28, for signal generation, controlled by programme segment, for free-selectable functions to be activated (e.g. activation of audible and visual signals, exhaust motors, fans, stirrers, etc. Only for units with TwinDISPLAY; max 2 contacts on 1-phase appliances; max 4 contacts on 3-phase appliances, 2 contacts H72
Process-dependent programmable door lock (only for units with TwinDISPLAY) D4
Door-open-recognition (only for units with TwinDISPLAY) V5
Flexible Pt100 for positioning in chamber or in load with socket, 4-pin, according to NAMUR NE 28, for external temperature recording (load temperature) max. 3 sensors Flexible Pt100 for positioning in chamber or in load with socket, 4-pin, according to NAMUR NE 28, for external temperature recording (load temperature) max. 3 sensors H4
Additional Pt100 temperature sensor, positioned flexibly in chamber or load, for local temperature measurement (up to 3 additional sensors are possible). The measured temperature can, if required, be indicated on the display, recorded in the integral ring store, and can be documented via the AtmoCONTROL software. Additional Pt100 temperature sensor, positioned flexibly in chamber or load, for local temperature measurement (up to 3 additional sensors are possible). The measured temperature can, if required, be indicated on the display, recorded in the integral ring store, and can be documented via the AtmoCONTROL software. H8
MobileALERT, notification by SMS in case of any error or alarm of the device. Requires option H6 “floating contact for alarm” C3
Temperature restriction - Temperatures: +60, +70, +80, +95, +100, +120, +160, +180, +200 or +250 °C (Please, indicate upon ordering) A8
Fresh-air filter (filtration efficiency 80 %) mounted at the bottom (for UF/UFplus). For model sizes 30 – 260, subframe or subframe on castors obligatory Fresh-air filter (filtration efficiency 80 %) mounted at the bottom (for UF/UFplus). For model sizes 30 – 260, subframe or subframe on castors obligatory R8
Castor frame (2-part), height 140 mm Castor frame (2-part), height 140 mm R9

Accessory

Accessory Order No.
Stainless steel grids, electropolished (standard equipment) Stainless steel grids, electropolished (standard equipment) E20164
Perforated stainless steel shelf Perforated stainless steel shelf B03916
Stainless steel slide-in drip tray, 15 mm rim (may affect the temperature distribution) - cannot be used in connection with option K1 E02072
Max. loading per slide-in drip tray (kg) 1,5
Stainless steel bottom drip tray, 15 mm rim (may affect the temperature distribution) - cannot be used in connection with option K1 B04358
Max. loading per bottom drip tray (kg) 1,5
Wall bracket for wall mounting Wall bracket for wall mounting B29757
Guarantee extension by 1 year GA1Q5
USB-Ethernet adapter E06192
Ethernet connection cable 5 m for computer interface E06189
USB User-ID stick (with User-ID licence): Oven-linked authorisation licence (User-ID-programme) on Memory-stick, prevents undesired manipulation by unauthorised third parties. When reordering please specify serial number (only for units with TwinDISPLAY) B33170
USB stick with documentation software AtmoCONTROL and operation manual for products with SingleDISPLAY (the standard equipment of appliances with TwinDISPLAY includes one USB stick with AtmoCONTROL) B33172
Set of height adjustable feet (4 pcs) B29768
Set of height adjustable feet (4 pcs). Standard on models ICOmed B29768
Stacking set (4 pcs) for stacking of appliances of same size (not for models 160, 260, 450, 750, 1060, ICH110, ICH110L and ICH110C) Stacking set (4 pcs) for stacking of appliances of same size (not for models 160, 260, 450, 750, 1060, ICH110, ICH110L and ICH110C) B29744
Plug-in tube extension (outer diam. 60,3 mm, inner 57 mm), straight, for exhaust air ducting (if necessary for connection by hose), only models U, I, S Plug-in tube extension (outer diam. 60,3 mm, inner 57 mm), straight, for exhaust air ducting (if necessary for connection by hose), only models U, I, S B29718
Plug-in tube extension (outer diam. 60,3 mm, inner 57 mm), angled, for exhaust air ducting (if necessary for connection by hose), only models U, I, S Plug-in tube extension (outer diam. 60,3 mm, inner 57 mm), angled, for exhaust air ducting (if necessary for connection by hose), only models U, I, S B29719
Flush-fit unit (stainless steel frame covering gap between oven and wall opening), with air slots – technical clarification required Flush-fit unit (stainless steel frame covering gap between oven and wall opening), with air slots – technical clarification required B29732
Flush-fit unit (stainless steel frame covering gap between oven and wall opening), without air slots – technical clarification required Flush-fit unit (stainless steel frame covering gap between oven and wall opening), without air slots – technical clarification required B29733
Subframe, adjustable in height (size 30 to 75: height 600 mm, size 110 to 450: height 500 mm) Subframe, adjustable in height (size 30 to 75: height 600 mm, size 110 to 450: height 500 mm) B29747
Subframe, on castors (size 30 to 75: height 660 mm, size 110 to 160: height 560 mm) Subframe, on castors (size 30 to 75: height 660 mm, size 110 to 160: height 560 mm) B29748
Subframe, adjustable in height (height 130 mm, for example for units with fresh-air filter) B33659
Integration of one additional unit (up to max. 31 units) into an already existent FDA-software licence FDAQ2
Software conforming to FDA AtmoCONTROL. Meets the requirements for the use of electronically stored data sets and electronic signatures as laid down in Regulation 21 CFR Part 11 of the US Food and Drug Administration (FDA). Base licence for reading and data logging of one unit (only for units with TwinDISPLAY). Respective IQ/OQ documents available in German and English language (without surcharge) FDAQ1
IQ/OQ document with works test data for chamber, incl. temperature distribution survey for one free-selectable temperature value. 9 measuring points (size 30), 27 measuring points (sizes 55 - 1060) to DIN 12880:2007-05 (further temperature values on demand), PQ check list as support for validation by customer D00127
IQ document with device-specific works test data, OQ/PQ check list as support for validation by customer D00124