Options / Accessories

Option Order No.
Works calibration certificate for one (freely selectable) temperature and humidity value D00105
Works calibration certificate for one (freely selectable) temperature, humidity, CO2 and O2 value according to customer specification (requires T6) D00143
Works calibration certificate for one (freely selectable) temperature, humidity and CO2 value according to customer specification (requires K7) D00131
Works calibration certificate for one (freely selectable) temperature and pressure value (per thermoshelf) according to customer specification D00116
Works calibration certificate for one (freely selectable) temperature value according to customer specification D00109
Temperature restriction - Temperatures: +50, +55, +60, +65, +70 or +75 °C (Please, indicate upon ordering) A8
Temperature restriction - Temperatures: +60, +70, +80, +95, +100, +120, +160, +180, +200 or +250 °C (Please, indicate upon ordering) A8
Flexible Pt100 temperature sensor, positioned flexibly in chamber or load, for local temperature measurement (up to 3 additional sensors are possible). The measured temperature can, if required, be indicated on the display, recorded in the integral data store, and can be documented via the AtmoCONTROL software H8
4 – 20 mA current loop interface (0 to +90°C = 4 - 20 mA) V3
Flexible Pt100 temperature sensor, positioned flexibly in chamber or load, for local temperature measurement (up to 2 additional sensors are possible). The measured temperature can, if required, be indicated on the display, recorded in the integral data store, and can be documented via the AtmoCONTROL software H8
4 – 20 mA current loop interface (0 to +260 °C ≙ 4 - 20 mA) Temperature controller actual value V3
4 – 20 mA current loop interface (0 to +260 °C ≙ 4 - 20 mA) Temperature of a Pt100 sensor positioned flexibly in chamber fo external temperature monitoring (max. 1 SingledDISPLAY, max. 3 TwinDISPLAY) - price per sensor V6
Locking mechanism to prevent simultaneous opening of doors for contamination protection in case of wall installation D5
Light module warm white 2,700 K: light strips arranged on the side walls of the interior, 10 for model 110, 14 for model 260/400/750, programme-controlled dimming from 0 to 100 % (in 1 % steps), ramp programming in combination with temperature (only with TwinDisplay) T9
Premium module: comprises the inert gas inlet (only size 49 and 101), extra connectors for thermoshelves, 1 (size 29), 2 (sizes 49/101), an additional thermoshelf (sizes 49/101) T5
Works calibration certificate for 3 temperatures: +50 °C, +100 °C, +160 °C at 20 mbar pressure. Price per thermoshelf D00115
Temperature restriction; Temperatures: +60, +70, +80, +95, +100, +120, +160 or +180 °C (Please, indicate upon ordering) A8
MobileALERT for 2 alarm notifications; temperature and vacuum alarm (only with option T5) C4
Flexible Pt100 for positioning in chamber or in load with socket, 4-pin, according to NAMUR NE 28, for external temperature recording (load temperature) H4
Potential-free contact (24 V/2 A) with socket, according to NAMUR NE 28 for combination error message (e.g. supply failure, sensor fault, fuse) H6
Freely positioned control sensor, MIN and MAX alarm adjustable at ControlCOCKPIT, alarm values captured in internal data logger H9
4 – 20 mA current loop interface (only with option T5) Temperature of a Pt100 sensor positioned flexibly in chamber for external temperature monitoring - price per sensor V6
4 – 20 mA current loop interface (only with option T5) Vacuum actual value (0 bis 1200 mbar = 4 - 20) W2
4 – 20 mA current loop interface (only with option T5) Temperature actual value (0 to 210 °C = 4 - 20 m) V3
4 – 20 mA current loop interface O2 controller, actual value (0 – 25 % O2 4 – 20 mA) V1
4 – 20 mA current loop interface CO2 controller, actual value (0 – 25 % CO2 4 – 20 mA) V9
Castor frame (2-part), height 140 mm
4 – 20 mA current loop interface Humidity controller, actual value (0 – 100 % rh 4 – 20 mA) V7
Works calibration certificate for one temperature according to customer specification (only TTC) D00109
Start-up of ICOmed incubators and brief training (D, A, CH only), through Memmert service, not subject to discount K9
Works calibration certificate for 5 %, 7 % and 10 % CO2 (measured at +37 °C) special works calibration certificates upon request D00106
4 – 20 mA current loop interface Temperature controller, actual value (0 to +70 °C 4 – 20 mA) V3
Inner door with partitioned glass doors (cannot be used in connection with option B8) K4
Entry port (silicone), 40 mm clear diameter, for introducing connections, moisture tight, can be closed by silicone stopper, at the back, centre right; not available for ICO50med with active humidity control (option K7) or humidity display (option K6) F7
Capacitive humidity sensor for measuring and displaying the relative humidity K6
Peltier cooling unit enables a working temperature of 37 °C even at higher ambient temperatures of up to 35 °C K5
Control of oxygen concentration by N2 inlet; adjustment range 1 % up to 20 % O2; setting accuracy 0.1 % (requires option K7) T6
Active microprocessor control for humidifying and dehumidifying (40 – 97 % rh), incl. digital indication and auto-diagnostic system ensures even more rapid reaching of set humidity and very short recovery times while avoiding condensate formation. Humidity supply with distilled water (from an external tank) by a self-priming pump; integral bacteria block by generating hotsteam, dehumidifying via sterile filter K7
Electropolished interior T2
MobileALERT for up to 4 alarm notifications; standard: temperature and CO2 alarm, additionally humidity alarm (when equipped with option K7) and O2 alarm (when equipped with option T6) C4
Battery-buffered ControlCOCKPIT. Uninterrupted supply for the entire display unit (ControlCOCKPIT) and therefore complete documentation of all parameteres even when there is a power failure. The CO2 parameter is continously regulated. C2
Voltage 115 V, 50/60 Hz (no extra cost) X2
Extended overtemperature protection for SingleDISPLAY devices by additionally integrated Pt100 sensor for independent temperature monitoring for models UN/UF A6
Full-sight glass door (4 insulating glass). Temperature-range up to max. 250 °C. Full-sight glass door (4 insulating glass). Temperature-range up to max. 250 °C. B0
Full-sight glass door (4 insulating glass). Temperature-range up to max. 300 °C - extra cost Full-sight glass door (4 insulating glass). Temperature-range up to max. 300 °C - extra cost B1
Fresh-air filter (filtration efficiency 80 %) mounted at the bottom (for UF/UFplus). For model sizes 30 – 260, subframe or subframe on castors obligatory Fresh-air filter (filtration efficiency 80 %) mounted at the bottom (for UF/UFplus). For model sizes 30 – 260, subframe or subframe on castors obligatory R8
Interior lighting for observing the load Interior lighting for observing the load R0
Interior socket (can only be ordered with limited temperature-range – max. +70°C - option A8 necessary) current carrying ampacity 230 V, 2.2 A can be switched off with the On/Off switch, cannot be switched individually, moisture tight IP68 R3
Interior nearly gastight K2
Interior nearly gastight with possibility for inlet/outlet through 2 tubes with ball valves K3
Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position left centre/centre Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position left centre/centre F0
Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position left centre top Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position left centre top F1
Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position right centre/centre Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position right centre/centre F2
Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position right centre top Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position right centre top F3
Entry port, 23 mm clear diameter for introducing connections at the side, can be closed by flap in special positions (please, state location) - left Entry port, 23 mm clear diameter for introducing connections at the side, can be closed by flap in special positions (please, state location) - left F4 F1
Entry port, 23 mm clear diameter for introducing connections at the side, can be closed by flap in special positions (please, state location) - right Entry port, 23 mm clear diameter for introducing connections at the side, can be closed by flap in special positions (please, state location) - right F5
Entry port, 23 mm clear diameter for introducing connections, can be closed by flap in special positions (please, state location) - rear Entry port, 23 mm clear diameter for introducing connections, can be closed by flap in special positions (please, state location) - rear F6
Entry port, 14 mm clear diameter, can be closed by flap, in special positions at the back (please, state location) Entry port, 14 mm clear diameter, can be closed by flap, in special positions at the back (please, state location) D6
Entry port, 38 mm clear diameter, can be closed by flap, in special positions at the back (please, state location) Entry port, 38 mm clear diameter, can be closed by flap, in special positions at the back (please, state location) F7
Entry port, 57 mm clear diameter, can be closed by flap, in special positions at the back (please, state location) Entry port, 57 mm clear diameter, can be closed by flap, in special positions at the back (please, state location) F8
Entry port, 100 mm clear diameter, can be closed by flap, in special positions at the back (please, state location) Entry port, 100 mm clear diameter, can be closed by flap, in special positions at the back (please, state location) F9
4 – 20 mA current loop interface (0 to +310°C corresponds to 4 – 20 mA) Temperature controller actual value V3
4 – 20 mA current loop interface (0 to +310°C corresponds to 4 – 20 mA) Temperature of a Pt100 sensor positioned flexibly in chamber for external temperature monitoring (max. 1 SingleDISPLAY, max. 3 TwinDISPLAY) V6
Fan speed monitoring with switching off the heating and with alarm in case of failure – optional for UFplus only V4
Works calibration certificate for 3 temperatures: +100°C, +160°C, +220°C. Standard works calibration certificate (measuring point chamber centre) at +160°C Works calibration certificate for 3 temperatures: +100°C, +160°C, +220°C. Standard works calibration certificate (measuring point chamber centre) at +160°C D00128
Chamber modification for the application of reinforced perforated stainless steel shelves or stainless steel grids (bearing rails mounted in the working chamber) – includes replacement of 2 standard grids by 2 reinforced grids K1
Extended overtemperature protection for SingleDISPLAY devices by additionally integrated Pt100 sensor for independent temperature monitoring for models IN/IF A6
Interior socket (can only be ordered with limited temperature-range – max. +70°C - option A8 necessary) current carrying ampacity 230 V, 2.2 A can be switched off with the On/Off switch, cannot be switched individually, moisture tight IP68 (only with SingleDISPLAY) R3
4 – 20 mA current loop interface (0 to +90°C corresponds to 4 – 20 mA) Temperature controller actual value V3
4 – 20 mA current loop interface (0 to +90°C corresponds to 4 – 20 mA) Temperature of a Pt100 sensor positioned flexibly in chamber for external temperature monitoring (max. 1 SingleDISPLAY, max. 3 TwinDISPLAY) V6
Fan speed monitoring with switching off the heating and with alarm in case of failure – optional for IFplus only V4
Works calibration certificate for 3 temperatures: +37°C, +52°C, +70°C. Standard works calibration certificate (measuring point chamber centre) at +37°C Works calibration certificate for 3 temperatures: +37°C, +52°C, +70°C. Standard works calibration certificate (measuring point chamber centre) at +37°C D00126
Extended overtemperature protection for SingleDISPLAY devices by additionally integrated Pt100 sensor for independent temperature monitoring for models SN/SF A6
Fresh-air filter (filtration efficiency 80 %) mounted at the bottom (for SF/SFplus). For model sizes 30 – 260, subframe or subframe on castors obligatory R8
4 – 20 mA current loop interface (0 to +260°C corresponds to 4 – 20 mA) Temperature controller actual value V3
4 – 20 mA current loop interface (0 to +260°C corresponds to 4 – 20 mA) Temperature of a Pt100 sensor positioned flexibly in chamber for external temperature monitoring (max. 1 SingleDISPLAY, max. 3 TwinDISPLAY) V6
Fan speed monitoring with switching off the heating and with alarm in case of failure – optional for SFplus only V4
Works calibration certificate for 3 temperatures: +160°C, +180°C, +250°C. Standard works calibration certificate (measuring point chamber centre) at +160°C D00132
Inert gas inlet: programmable and digitally controlled inlet for inert gas with flow rate reduction W5
Premium module: comprises the inert gas inlet (only size 49 and 101), extra connectors for thermoshelves, 1 (size 29), 2 (sizes 49/101), an additional thermoshelf (sizes 49/101)
Works calibration certificate for 3 temperatures: +50°C, +100°C, +160°C at 20 mbar pressure D00115
Extended temperature-range (0°C to +90°C) A8
Works calibration certificate for 3 temperatures: +5°C, +30°C, +90°C at 20 mbar pressure D00133
Interior socket, ampacity 230 V/2.2 A, can be switched off with the On/Off switch, cannot be switched individually, moisture tight IP68 R3
4 – 20 mA current loop interface (-10 to +80°C corresponds to 4 – 20 mA) Temperature controller actual value V3
4 – 20 mA current loop interface (-10 to +80°C corresponds to 4 – 20 mA) Temperature of a Pt100 sensor positioned flexibly in chamber for external temperature monitoring (max. 1 SingleDISPLAY, max. 3 TwinDISPLAY) V6
Works calibration certificate for 3 temperatures: +5°C, +37°C, +60°C. Standard works calibration certificate (measuring point chamber centre) at +10°C and +37°C Works calibration certificate for 3 temperatures: +5°C, +37°C, +60°C. Standard works calibration certificate (measuring point chamber centre) at +10°C and +37°C D00129
Light module cold white 6,500 Kelvin: light strips arranged on the side walls of the interior, 10 strips for model 110, 14 for model 260/750, programme-controlled dimming from 0 to 100 % (in 1 % steps), ramp programming in combination with temperature (only with TwinDISPLAY) T7
Light module warm white 2,700 K: light strips arranged on the side walls of the interior, 10 for model 110, 14 for model 260/400/750, programme-controlled dimming from 0 to 100 % (in 1 % steps), ramp programming in combination with temperature and humidity T9
Light module cold white 6,500 Kelvin + warm white 2,700 Kelvin: LED light strips -10 strips for model 110, 14 for model 260/750 - (5 resp. 7 alternating cold white light strips and 5 resp. 7 warm white light strips) on the side walls of the interior, programmecontrolled dimming from 0 to 100 % (in 1 % steps), ramp programming in combination with temperature (only with TwinDISPLAY) T8
Voltage 115 V, 50/60 Hz X2
4 – 20 mA current loop interface (-20 to +70°C corresponds to 4 – 20 mA) Temperature controller actual value V3
4 – 20 mA current loop interface (-20 to +70°C corresponds to 4 – 20 mA) Temperature of a Pt100 sensor positioned flexibly in chamber for external temperature monitoring (max. 3 TwinDISPLAY) V6
Fan speed monitoring with switching off the heating and with alarm in case of failure V4
Entry port (silicone), 40 mm clear diameter, for introducing connections, moisture tight, can be closed by silicone stopper, at the back (please, state location) F7
Works calibration certificate for 3 temperatures: 0°C, +37°C, +60°C. Standard works calibration certificate (measuring point chamber centre) at +10°C and +37°C Works calibration certificate for 3 temperatures: 0°C, +37°C, +60°C. Standard works calibration certificate (measuring point chamber centre) at +10°C and +37°C D00130
Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position left centre/centre Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position left centre/centre F0
Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position left centre top Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position left centre top F1
Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position right centre/centre Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position right centre/centre F2
Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position right centre top Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position right centre top F3
Entry port, 23 mm clear diameter for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper (please, state location) - left Entry port, 23 mm clear diameter for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper (please, state location) - left F4
Entry port, 23 mm clear diameter for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper (please, state location) - right Entry port, 23 mm clear diameter for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper (please, state location) - right F5
Entry port, 23 mm clear diameter for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper (please, state location) - rear Entry port, 23 mm clear diameter for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper (please, state location) - rear F6
4 – 20 mA current loop interface (-10 to +80°C corresponds to 4 to 20 mA) Temperature controller, actual value V3
4 – 20 mA current loop interface (-10 to +80°C corresponds to 4 to 20 mA) Temperature of a Pt100 sensor positioned flexibly in chamber for external temperature monitoring (max. 3 TwinDISPLAY) V6
4 – 20 mA current loop interface (-10 to +80°C corresponds to 4 to 20 mA) Humidity controller, actual value (0 – 100 % rh corresponds to 4 – 20 mA) V7
Works calibration certificate for one (freely selectable) temperature and humidity value. Standard works calibration certificate (measuring point chamber centre) at +10°C, +37°C and 60 % rh at +30°C (sizes 1060/1400 for +25 °C/40 % rh and +40 °C/75 % rh) D00105
Compressed air dehumidification (efficient dehumidification of the interior by means of compressed air). Standard works calibration certificate (measuring point chamber centre) at +10 °C with 10 % rh. C9
Door-hinges on left side B8
Works calibration certificate for 80 % rh (measured at +50°C) D00107
Start-up of HCP and brief training (D, A, CH only) through MEMMERT service, (not subject to discount) K9
Stacking version for 2 units of equal size (bottom unit modification) G3
Process-dependent electromagnetic door lock D4
Water level control (for WNB, WNE, WPE) Water level control (for WNB, WNE, WPE) L3
Works calibration certificate (37°C for WNB, WNE, WPE, 160°C for ONE) Works calibration certificate (37°C for WNB, WNE, WPE, 160°C for ONE) D00123
Adjustable temperature limiter, safety device class 2 instead of adjustable overheat controller safety device class 3.1, no extra cost
Full-sight glass door triple-insulating glass) Full-sight glass door triple-insulating glass) B0
Reinforced chamber (max. loading up to 300 kg (involves narrower reinforced grids) includes replacement of 2 standard grids by 2 reinforced grids
Process-dependent electromagnetic door lock (both sides) D4
Locking mechanism with SPS control to prevent simultaneous opening of doors for contamination protection in case of wall installation
Works calibration certificate for one temperature and humidity according to customer specification (only CTC) D00105
Full-sight glass door (5-layer insulating glazing), heated B0
Entry port, left, 80 mm, with stopper F0
Start-up of CTC and TTC chambers and brief training (D, A, CH only) through Memmert service, (not subject to discount) K9
Entry port, 23 mm clear diameter, for introducing connections at the side, gas tight, can be closed by flap and silicone stopper, standard position left centre/centre Entry port, 23 mm clear diameter, for introducing connections at the side, gas tight, can be closed by flap and silicone stopper, standard position left centre/centre F0
Entry port, 23 mm clear diameter, for introducing connections at the side, gas tight, can be closed by flap and silicone stopper, standard position left centre top Entry port, 23 mm clear diameter, for introducing connections at the side, gas tight, can be closed by flap and silicone stopper, standard position left centre top F1
Entry port, 23 mm clear diameter, for introducing connections at the side, gas tight, can be closed by flap and silicone stopper, standard position right centre/centre Entry port, 23 mm clear diameter, for introducing connections at the side, gas tight, can be closed by flap and silicone stopper, standard position right centre/centre F2
Entry port, 23 mm clear diameter, for introducing connections at the side, gas tight, can be closed by flap and silicone stopper, standard position right centre top Entry port, 23 mm clear diameter, for introducing connections at the side, gas tight, can be closed by flap and silicone stopper, standard position right centre top F3
Entry port, 23 mm clear diameter for introducing connections at the side, gas tight, can be closed by flap and silicone stopper, in special positions (please, state location) - left Entry port, 23 mm clear diameter for introducing connections at the side, gas tight, can be closed by flap and silicone stopper, in special positions (please, state location) - left F4
Entry port, 23 mm clear diameter for introducing connections at the side, gas tight, can be closed by flap and silicone stopper, in special positions (please, state location) - right Entry port, 23 mm clear diameter for introducing connections at the side, gas tight, can be closed by flap and silicone stopper, in special positions (please, state location) - right F5
Entry port, 23 mm clear diameter for introducing connections at the side, gas tight, can be closed by flap and silicone stopper, in special positions (please, state location) - rear Entry port, 23 mm clear diameter for introducing connections at the side, gas tight, can be closed by flap and silicone stopper, in special positions (please, state location) - rear F6
Entry port, 40 mm clear diameter, for introducing connections, gas tight, can be closed by flap and silicone stopper, in special positions at the back (please, state location) F7
4 – 20 mA current loop interface (0 to +90°C corresponds to 4 – 20 mA) Temperature of a Pt100 sensor positioned flexibly in chamber for external temperature monitoring (max. 3 TwinDISPLAY) V6
Gas inlet/outlet through 2 tubes with ball valves K3
Works calibration certificate for 3 temperatures: +37°C, +52°C, +70°C. Standard works calibration certificate (measuring point chamber centre) at +80°C D00126
4 – 20 mA current loop interface (0 to +70°C corresponds to 4 – 20 mA) Temperature controller actual value V3
4 – 20 mA current loop interface (0 to +70°C corresponds to 4 – 20 mA) Temperature of a Pt100 sensor positioned flexibly in chamber for external temperature monitoring (max. 1 SingleDISPLAY) V6
Entry port, 120 mm clear diameter, can be closed by flap, in special positions at the back (please, state location) Entry port, 120 mm clear diameter, can be closed by flap, in special positions at the back (please, state location)
Alternative light boxes (replace the standard lighting; have to be ordered together with the chamber); number of fluorescent lamps: size 110: 5, sizes 260/750: 6, with cold white light (daylight: light colour 865, 6.500K; daylight complies with standard illuminant D65) (only ICHeco L/ICH L) one box T81
Alternative light boxes (replace the standard lighting; have to be ordered together with the chamber); number of fluorescent lamps: size 110: 5, sizes 260/750: 6, with cold white light (daylight: light colour 865, 6.500K; daylight complies with standard illuminant D65) (only ICHeco L/ICH L) second box (cannot be switched on separately) T82
Alternative light boxes (replace the standard lighting, have to be ordered together with the chamber), number of fluorescent UV lamps: size 110: 5, sizes 260/750: 6, in the spectral range of 315 to 400 nm, 22 W/m2, (only ICH L) one box, no extra cost T01
4 to 20 mA current loop interface (-20 to +70°C corresponds to 4 to 20 mA) (Models ICH C max. 2 interfaces – only combination V3 + V7 or V3 + V9 possible) Temperature controller, actual value V3
4 to 20 mA current loop interface (-20 to +70°C corresponds to 4 to 20 mA) (Models ICH C max. 2 interfaces – only combination V3 + V7 or V3 + V9 possible) Temperature of a Pt100 sensor positioned flexibly in chamber for external temperature monitoring (max. 3 TwinDISPLAY) V6
4 to 20 mA current loop interface (-20 to +70°C corresponds to 4 to 20 mA) (Models ICH C max. 2 interfaces – only combination V3 + V7 or V3 + V9 possible) Humidity controller, actual value (0 – 100 % corresponds to rh 4 – 20 mA) V7
4 to 20 mA current loop interface (-20 to +70°C corresponds to 4 to 20 mA) (Models ICH C max. 2 interfaces – only combination V3 + V7 or V3 + V9 possible) CO2 controller, actual value (0 – 25 % CO2 corresponds to 4 – 20 mA) V9
Works calibration certificate for one (freely selectable) temperature and humidity value. Standard works calibration certificate (measuring point chamber centre) at +10°C, +37°C and +30°C with 60 % rh D00105
Compressed air dehumidification (efficient dehumidification of the interior by means of compressed air – for models ICH and ICH L). Standard works calibration certificate (measuring point chamber centre) at +10 °C with 10 % rh. C9
Illumination unit consisting of 4 fluorescent lights with cold white light (standard illuminant D65, 6,500 K) and 2 UV lamps in the spectral range of 320 to 400 nm, 8 W/m2, acc. ICH Q1B option 2, light intensity approx. 8,000 Lux, separately switchable via controller (only ICH L) second box T72
Alternative light boxes (replace the standard lighting, have to be ordered together with the chamber), number of fluorescent UV lamps: size 110: 5, sizes 260/750: 6, in the spectral range of 315 to 400 nm, 22 W/m2, (only ICH L) second box, cannot be switched on seperately T02
Chamber modification for the application of reinforced perforated stainless steel shelves or stainless steel grids (bearing rails mounted in the working chamber) – includes replacement of 2 standard grids by 2 reinforced grids (ICH and ICH C only) K1
Two gas connections with quick release connectors, automatic switch-over of gas cylinders; incl. two CO2 connection sets: hose with coupling and clamp T1
Hygiene module: electropolished interior seamlessly welded by laser T2
Communication module: USB interface, "Celsius" standard software for programming and logging, ring log memory, printer interface T3
CO2 module: extended CO2 range from 0 to 20 % T4
Premium module: includes Comfort, Hygiene, Communication and CO2 module T5
Humidity-Modul: active microprocessor control for humidifying and dehumidifying (40-97 % rh), incl. digital indication and auto-diagnostic system ensures even more rapid reaching of set humidity and very short recovery times while avoiding condensate formation, recommended for applications with set O2 values of less than 10 %, humidity supply with distilled water (from an external tank) by a self-priming pump, integral bacteria block by generating hotsteam, dehumidifying via sterile filter, (standard humidity limit control and water dishes are omitted). Can only be ordered together with new incubator K7
O2 module: control of oxygen concentration by N2 inlet, adjustment range 1 % up to 20 % O2, setting accuracy 0,1 %, (Combination of comfort module or Premium module and O2 module not possible), for applications with a set O2-value of less than 10 %, the humidity module is highly recommended. T6
Entry port (silicone), 40 mm clear diameter, for introducing connections, moisture tight, can be closed by silicone stopper, at the back either centre right or centre left (please, state location) F7
Potential-free contact (24V/2A) with socket 3 pin,
according to NAMUR NE 28 for external monitoring
(setpoint of temperature and CO<sub>2</sub> is reached) Potential-free contact (24V/2A) with socket 3 pin, according to NAMUR NE 28 for external monitoring (setpoint of temperature and CO2 is reached) H5
Works calibration certificate for 5 %, 7 % and 10 % CO2 (measured at +37°C) D00106
Start-up of INCO incubators and brief training (D, A, CH only), through MEMMERT service, not subject to discount K9
4-part partitioning of interior with gas baffle (replacement of 3 full-width by 6 half-width shelves) K4
Interface Ethernet instead of USB including software W4
RS232 interface instead of USB W6
Computer interface RS485 (for networking a max. of 16 ovens) instead of RS232 V2
Door with lock (safety lock, not available for VO, VOcool, TTC/CTC) B6
Flexible Pt100 for positioning in chamber or in load with socket, 4-pin, according to NAMUR NE 28, for external temperature recording (load temperature) Flexible Pt100 for positioning in chamber or in load with socket, 4-pin, according to NAMUR NE 28, for external temperature recording (load temperature) H4
Flexible Pt100 temperature sensor, positioned flexibly in chamber or load, for local temperature measurement (up to 3 additional sensors are possible). The measured temperature can, if required, be indicated on the multifunction display, recorded in the integral ring store, and can be documented via the “Celsius” software or on an attached printer. (not available for VO, VOcool, TTC and CTC) Flexible Pt100 temperature sensor, positioned flexibly in chamber or load, for local temperature measurement (up to 3 additional sensors are possible). The measured temperature can, if required, be indicated on the multifunction display, recorded in the integral ring store, and can be documented via the “Celsius” software or on an attached printer. (not available for VO, VOcool, TTC and CTC) H8
Potential-free contact (24 V/2 A) with socket, according to NAMUR NE 28 for external monitoring (indicates when setpoint is reached); VO only in combination with option T5 Potential-free contact (24 V/2 A) with socket, according to NAMUR NE 28 for external monitoring (indicates when setpoint is reached); VO only in combination with option T5 H5
Potential-free contact (24 V/2 A) with socket, according to NAMUR NE 28 for combination error message (e.g. supply failure, sensor fault, fuse); VO only in combination with option T5 Potential-free contact (24 V/2 A) with socket, according to NAMUR NE 28 for combination error message (e.g. supply failure, sensor fault, fuse); VO only in combination with option T5 H6
Potential-free contact (24 V/2 A) with socket, according to NAMUR NE 28, triple, for signal generation, controlled by programme segment for a total of 3 freely selected functions to be activated (e.g. acoustic and visual signals, exhaust motors, fans, stirrers etc.) Potential-free contact (24 V/2 A) with socket, according to NAMUR NE 28, triple, for signal generation, controlled by programme segment for a total of 3 freely selected functions to be activated (e.g. acoustic and visual signals, exhaust motors, fans, stirrers etc.) H7
Door with lock (safety lock), Standard with SN/SF and SNplus/SFplus 450 and 750 Door with lock (safety lock), Standard with SN/SF and SNplus/SFplus 450 and 750 B6
Door with lock (safety lock), two locks (one each door) B62
Door with lock (safety lock), three locks (one each door) B63
Door hinged on the left B8
Potential-free contact (24 V/2 A) with socket to NAMUR NE 28 for external monitoring (indicates when setpoint is reached) Potential-free contact (24 V/2 A) with socket to NAMUR NE 28 for external monitoring (indicates when setpoint is reached) H5
Potential-free contact for combination error message (e.g. supply failure, sensor fault, fuse) Potential-free contact for combination error message (e.g. supply failure, sensor fault, fuse) H6
Potential-free contact (24 V/2 A) with socket to NAMUR NE 28, for signal generation, controlled by programme segment, for free-selectable functions to be activated (e.g. activation of audible and visual signals, exhaust motors, fans, stirrers, etc. Only for units with TwinDISPLAY; max 2 contacts on 1-phase appliances; max 4 contacts on 3-phase appliances, 2 contacts Potential-free contact (24 V/2 A) with socket to NAMUR NE 28, for signal generation, controlled by programme segment, for free-selectable functions to be activated (e.g. activation of audible and visual signals, exhaust motors, fans, stirrers, etc. Only for units with TwinDISPLAY; max 2 contacts on 1-phase appliances; max 4 contacts on 3-phase appliances, 2 contacts H7 H72
Process-dependent programmable door lock (only for units with TwinDISPLAY) D4
Process-dependent programmable door lock, two interlocking systems (one each other) D42
Process-dependent programmable door lock, three interlocking systems (one each other) D43
Door-open-recognition (only for units with TwinDISPLAY) V5
Door-open-recognition, two (one each door) V52
Door-open-recognition, three (one each door) V53
Flexible Pt100 for positioning in chamber or in load with socket, 4-pin, according to NAMUR NE 28, for external temperature recording (load temperature) max. 3 sensors Flexible Pt100 for positioning in chamber or in load with socket, 4-pin, according to NAMUR NE 28, for external temperature recording (load temperature) max. 3 sensors H4
Additional Pt100 temperature sensor, positioned flexibly in chamber or load, for local temperature measurement (up to 3 additional sensors are possible). The measured temperature can, if required, be indicated on the display, recorded in the integral ring store, and can be documented via the AtmoCONTROL software or on an attached printer. Additional Pt100 temperature sensor, positioned flexibly in chamber or load, for local temperature measurement (up to 3 additional sensors are possible). The measured temperature can, if required, be indicated on the display, recorded in the integral ring store, and can be documented via the AtmoCONTROL software or on an attached printer. H8
MobileALERT, notification by SMS in case of any error or alarm of the device. Requires option H6 “floating contact for alarm” C3
Temperature restriction (for models UN/UF/UNplus/UFplus, IN/IF/INplus/IFplus) Temperatures: +60, +70, +80, +95, +100, +120, +160, +180, +200 or +220 °C (Please, indicate upon ordering) A8
Castor frame (2-part), height 140 mm Castor frame (2-part), height 140 mm R9 B29762 B29763 B29764
Potential-free contact (24 V/2 A) with socket to NAMUR NE 28, for signal generation, controlled by programme segment, for a total of 3 freely selectable functions to be activated (e.g. activation of audible and visual signals, exhaust motors, fans, stirrers, etc. (only for units with TwinDISPLAY), max 2 contacts for 1-ph. units, max 4 contacts for 3-ph. units,4 contacts H74

Accessory Order No.
Stainless steel grid, electropolished E20165 E28891 E20182
Flush-fit unit set (stainless steel frame covering gap between oven and wall opening), without air slots - technical clarification required B33204 B33205 B33206 B33207
Additional reinforced stainless steel grid, electropolished, max. loading 60 kg; with guide bars and fixing screws (only in connection with option K1). Please consider max. loading of chamber B32190
IQ/OQ document with device-specific works test data for one free-selectable temperature and vacuum value, incl. temperature distribution survey at Memmert for 5 measuring points per thermoshelf to DIN 12880:2007-05. PQ check list as support for validation by customer valid for one thermoshelf; dito further thermoshelves, price on demand. D00117
Noise-insulated vacuum pump module, as above, however with built-in pump, 230 V, 50/60 Hz PMP29 PMP49 PMP101 PMP 29 PMP 49
Noise-insulated vacuum pump module without pump (exterior dimensions and -material No. s. vacuum oven) with antivibration metal plate at the bottom to accommodate the vacuum pump, incl. full-sight glass door. Socket, signal cable and connecting hose to the vacuum oven PM29 PM49 PM101
Subframe, tubular steel, black enamelled (for stacking unit consisting of vacuum oven and pump module, total height: 1650 mm, see "further data" and sketch of oven dimensions) E02030 E02031 E02037
Signal cable (3 m) for control of roation speed and optimising pump performance by demand-controlled activation of purge of Memmert pump (not required with pump module) B39410
Vacuum pump with chemically resistant 4x diaphragm, pump capacity at atm. pressures: approx. 50 Nl./min = 3,0 m/h3 and autom. purge control. Order No. B39410 and B04026 necessary. 230 V, 50 Hz. Max. guarantee period 2 years E07509
Ethernet connection cable 5 m for computer interface E06189
USB User-ID stick (with User-ID licence): Oven-linked authorisation licence (User-ID-programme) on Memory-stick, prevents undesired manipulation by unauthorised third parties. When reordering please specify serial number B33170
Software conforming to FDA AtmoCONTROL. Meets the requirements for the use of electronically stored data sets and electronic signatures as laid down in Regulation 21 CFR Part 11 of the US Food and Drug Administration (FDA). Base licence for the control of one unit. Respective IQ/OQ documents available in German and English language (without surcharge) FDAQ1
Integration of one additional unit (up to max. 15 units) into an already existent FDA-software licence FDAQ2
IQ document with device-specific works test data, OQ/PQ check list as support for validation by customer D00124
IVF module for ICO50med: patented, consisting of 6 slide-in units, a total of 12 special racks with indentations for 12 Petri dishes (60 mm diam.) resp. 24 Petri dishes (35 mm diam.), 2 racks with indentations for 3 special media tubes each; racks with indentations for 4-well dishes on demand; only for ICO50med with the options K7 and F7; works calibration certificate (measuring point chamber centre) at +37 °C, 5 %, 6 % and 7 % CO2 as well as 90 % rh; 5 % O2 for IVF unit equipped with option T6 B44128
IVF module for ICO105med: patented, consisting of 8 slide-in units, a total of 16 special racks with indentations for 16 Petri dishes (60 mm diam.) resp. 32 Petri dishes (35 mm diam.), 2 racks with indentations for 3 special media tubes each; racks with indentations for 4-well dishes on demand; only for ICO105med with the options K7 and F7; works calibration certificate (measuring point chamber centre) at +37 °C, 5 %, 6 % and 7 % CO2 as well as 90 % rh; 5 % O2 for IVF unit equipped with option T6 B42398
IQ/OQ document with device-specific works test data for one freeselectable temperature value, incl. temperature distribution survey at Memmert for 9 measuring points to DIN 12876.2. Further temperature values and validation at customer site on demand. D00125
Stacking set (consisting of stacking corners, one connecting plate for the rear, two wall brackets) for stacking two units ICO150med or ICO240med B42114 B42115
Stainless steel bottom drip tray, 15 mm rim (can be used only in connection with option K1) B34055
Stainless steel slide-in drip tray, 15 mm rim, with guide bars and fixing screws (can be used only in connection with option K1) B32763
IQ/OQ document with device-specific works test data for one free-selectable CO2, humidity and temp. value, incl. temp. distribution survey at Memmert for 27 measuring points to DIN 12880:2007-05, PQ check list as support for validation by customer (models ICH C and ICOmed, on models ICOmed a free-selectable humidity value is only possible with option K7).
HEPA-filter for chamber (filter class E11) according to EN 1822, packed in sterile condition, incl. fixing unit B38739
Subframe (130 mm high); sizes 150/240: only in combination with the corresponding stacking sets for stacked appliances. B33507 B33508 B33509
Subframe (622 mm high) adjustable in height (sizes 150/240: should not be used for 2 stacked units) B33504 B33505 B33506
Additional water dish (not applicable with option K7) B38737
IQ/OQ document with device-specific works test data for one freeselectable CO2 and temperature value, incl. temperature distribution survey at Memmert for 27 measuring points to DIN 12880:2007-05, PQ check list as support for validation by customer (models ICOmed). D38898
IQ/OQ document with device-specific works test data for one free-selectable CO2, humidity and temperature value, incl. temperature distribution survey at Memmert for 27 measuring points to DIN 12880:2007-05, PQ check list as support for validation by customer (models ICH C and ICOmed, on models ICOmed a free-selectable humidity value is only possible with option K7). D38897
Ethernet connection cable 5 m for computer interface E06189
Stainless steel grids, electropolished (standard equipment) Stainless steel grids, electropolished (standard equipment) E28884 E20164 E20165 E28891 E20182 B32550 B41251 B38955
Reinforced stainless steel grid, max. loading 60 kg, from size 450 with guide bars and fixing screws and only in connection with option K1 E29767 E29766 B32190
Perforated stainless steel shelf Perforated stainless steel shelf B29727 B03916 B00325 B29725 B00328 B32549 B00326
Reinforced perforated stainless steel shelves, max. loading 60 kg, with guide bars and fixing screws and only in connection with option K1 Reinforced perforated stainless steel shelves, max. loading 60 kg, with guide bars and fixing screws and only in connection with option K1 B32191 E29766
Max. loading per slide-in drip tray (kg) 1,5 3 4 8 5
Max. loading per bottom drip tray (kg) 1,5 3 4 8 5
Wall bracket for wall mounting Wall bracket for wall mounting B29755 B29756 B29757 B29758 B29759
Guarantee extension by 1 year GA2Q5
Additional thermoshelves – aluminium eloxadised material W.-St. 3.3547 (ASTM B209) with integrated large-area heating including local temperature sensing (Pt100, 4-wire-circuit), individual overtemp. protection for each shelf MLOP (Multi-Level-Overtemperature-Control) and calibration certificate B00741 B00743 B00744
Additional thermoshelves – stainless steel material 1.4404 (ASTM 316 L) for especially corrosive material with integrated large-area heating including local temperature sensing (Pt100, 4-wire-circuit), individual overtemp. protection for each shelf MLOP (Multi-Level-Overtemperature-Control) and calibration certificate Additional thermoshelves – stainless steel material 1.4404 (ASTM 316 L) for especially corrosive material with integrated large-area heating including local temperature sensing (Pt100, 4-wire-circuit), individual overtemp. protection for each shelf MLOP (Multi-Level-Overtemperature-Control) and calibration certificate B00733 B00734 B00735
Removable bottom drip tray – stainless steel material 1.4404 (ASTM 316 L) E04256 E04257 E04258
Subframe, tubular steel, black enamelled (for stacking unit consisting of vacuum oven and pump module, total height: 1650 mm) Width/ Height/ Depth: model 200: 529/450/383, model 400: 529/290/463, model 500: 689/130/533 Subframe, tubular steel, black enamelled (for stacking unit consisting of vacuum oven and pump module, total height: 1650 mm) Width/ Height/ Depth: model 200: 529/450/383, model 400: 529/290/463, model 500: 689/130/533 E02030 E02031 E02037
Guarantee extension by 1 year (VO only) GA2Q5
Noise-insulated vacuum pump module without pump (exterior dimensions and material No. see vacuum oven) with antivibration metal plate at the bottom to accommodate the vacuum pump, incl. full-sight glass door. Socket, signal cable and connecting hose to the vacuum oven Noise-insulated vacuum pump module without pump (exterior dimensions and material No. see vacuum oven) with antivibration metal plate at the bottom to accommodate the vacuum pump, incl. full-sight glass door. Socket, signal cable and connecting hose to the vacuum oven PM 200 PM 400 PM 500
Noise-insulated vacuum pump module, as above, however with built-in pump, 230 V, 50/60 Hz (pump B04133 for VO 200 and pump B04134 for VO 400 and 500) Noise-insulated vacuum pump module, as above, however with built-in pump, 230 V, 50/60 Hz (pump B04133 for VO 200 and pump B04134 for VO 400 and 500) PMP 200 PMP 400 PMP 500
Signal cable (3 m) for optimising pump performance by demand-controlled activation of purge of Memmert pump B04027
Vacuum connecting hose (3 m) from oven to Memmert pump incl. optimised connection accessories (partially stainless steel) Vacuum connecting hose (3 m) from oven to Memmert pump incl. optimised connection accessories (partially stainless steel) B04026
Chemically resistant vacuum pump with PTFE double diaphragm, pump capacity at atm. pressures: approx. 34 Nl./min = 2,04 m³/h and autom. purge control from vacuum oven. Order No. B04027 and B04026 necessary. 230 V, 50/60 Hz. Max. guarantee period 2 years Chemically resistant vacuum pump with PTFE double diaphragm, pump capacity at atm. pressures: approx. 34 Nl./min = 2,04 m³/h and autom. purge control from vacuum oven. Order No. B04027 and B04026 necessary. 230 V, 50/60 Hz. Max. guarantee period 2 years B04133
Chemically resistant vacuum pump with PTFE double diaphragm, pump capacity at atm. pressures: approx. 60 Nl./min = 3,6 m³/h and autom. purge control from vacuum oven. Order No. B04027 and B04026 necessary. 230 V, 50/60 Hz. Max. guarantee period 2 years Chemically resistant vacuum pump with PTFE double diaphragm, pump capacity at atm. pressures: approx. 60 Nl./min = 3,6 m³/h and autom. purge control from vacuum oven. Order No. B04027 and B04026 necessary. 230 V, 50/60 Hz. Max. guarantee period 2 years B04134
Subframe, tubular steel, black enamelled (for stacking unit consisting of vacuum oven and pump module, total height: 1650 mm) Width/ Height/ Depth: model 200: 529/450/383, model 400: 529/290/463 Subframe, tubular steel, black enamelled (for stacking unit consisting of vacuum oven and pump module, total height: 1650 mm) Width/ Height/ Depth: model 200: 529/450/383, model 400: 529/290/463 E02030 E02031
Guarantee extension by 1 year (VOcool only) GA2Q5
Reinforced stainless steel grid, max. loading 60 kg (size 750 with guide bars and fixing screws and only in connection with option K1) E29767 E29766 B32190
Reinforced stainless steel grid, max. loading 60 kg, from size 450 with guide bars and fixing screws and only in connection with option K1 E29767 E29766 B32190
Reinforced stainless steel grid, electropolished, max. loading 60 kg (model 750 with guide bars and fixing screws and only in connection with option K1) E29767 E29766 B32190 B32550
Perforated stainless steel shelves B00325 B29725 B00328 B32549
Reinforced perforated stainless steel shelf, max. loading 60 kg, with guide bars and fixing screws and only in connection with option K1) Reinforced perforated stainless steel shelf, max. loading 60 kg, with guide bars and fixing screws and only in connection with option K1) B32191
Max. loading per slide-in drip tray (kg) 3 4 8
Max. loading per bottom drip tray (kg) 3 4 8
Holder for water tank (sizes 110 - 750: 2.5 litres, sizes 1060/1400/2200: 10 litres) for mounting on the rear of the appliance. Standard equipment for sizes 750, 1060, 1400 und 2200. E32172
Central water supply with filter cartridges for connection to the domestic water supply. Product information on demand. ZWVR6 ZVWR6
Central water supply without filter cartridges for connection to the domestic water supply (only for demineralised water in accordance with VDE 0510/DIN EN 50272). Product information on demand ZWVR7
Additional perforated stainless steel shelf B00325 B00321 B03813 E35160 E37418 E35158
Additional stainless steel grid Additional stainless steel grid E20165 E20166 E29766 E20591 E20164
Subframe, adjustable in height (622 mm high) Subframe, adjustable in height (622 mm high) B02792 B02732 B02793
Subframe, (130 mm high for 2 stacked cabinets) B02794 B02740 B02795
STERICard (additional or as replacement) for automatic chamber sterilisation cycle (not for sterilising the load!) E04337
Stainless steel gable cover, also suitable for shaking device (14/22 und 29/45) or Peltier cooling unit CDP 115 Stainless steel gable cover, also suitable for shaking device (14/22 und 29/45) or Peltier cooling unit CDP 115 B02641 B02642 B02643 B04390
Flat stainless steel cover with concentric ring sets for ring set openings: 1 opening / 147 mm diameter Flat stainless steel cover with concentric ring sets for ring set openings: 1 opening / 147 mm diameter B02680
Flat stainless steel cover with concentric ring sets for Peltier cooling CDP115: 1 opening / 147 mm diameter Flat stainless steel cover with concentric ring sets for Peltier cooling CDP115: 1 opening / 147 mm diameter B24372
Shelf reversible for 2 heights (30 or 60 mm) Shelf reversible for 2 heights (30 or 60 mm) E02893 E02894 E02895 E02896
Peltier cooling device CDP115 for waterbaths for temperatures below ambient from +10 °C, Voltage 230 V, 50/60 Hz, or 115 V, 60 Hz (please state in case of order). 
Please do not forget to order the installation and connection set! Peltier cooling device CDP115 for waterbaths for temperatures below ambient from +10 °C, Voltage 230 V, 50/60 Hz, or 115 V, 60 Hz (please state in case of order). Please do not forget to order the installation and connection set! CDP115
Installation and connection set for Peltier cooling device CDP115 (incl. mounting bars for all different bath sizes) B02770
Shaking device incl. support frame, shaking frequency 35 – 160 strokes per minute (horizontal back/forth movement), requires gable cover Shaking device incl. support frame, shaking frequency 35 – 160 strokes per minute (horizontal back/forth movement), requires gable cover SV1422 SV2945
Support basket with perforated mounting shelf (stainless steel) with grid perforations to take clips for conical flasks Support basket with perforated mounting shelf (stainless steel) with grid perforations to take clips for conical flasks B02782 B04397
Flat stainless steel cover with concentric ring sets for ring set openings: 3 openings / 107 mm diameter Flat stainless steel cover with concentric ring sets for ring set openings: 3 openings / 107 mm diameter B02681
Flat stainless steel cover with concentric ring sets for Peltier cooling CDP115: 3 openings / 107 mm diameter Flat stainless steel cover with concentric ring sets for Peltier cooling CDP115: 3 openings / 107 mm diameter B24373
Portable stainless steel rack for 10 baby bottles: maximum capacity each bath: size 10: 1 rack, size 14: 2 racks, size 29: 4 racks Portable stainless steel rack for 10 baby bottles: maximum capacity each bath: size 10: 1 rack, size 14: 2 racks, size 29: 4 racks E02066
Flat stainless steel cover with concentric ring sets for ring set openings: 6 openings / 87 mm diameter Flat stainless steel cover with concentric ring sets for ring set openings: 6 openings / 87 mm diameter B02682
Flat stainless steel cover with concentric ring sets for Peltier cooling CDP115: 6 openings / 87 mm diameter Flat stainless steel cover with concentric ring sets for Peltier cooling CDP115: 6 openings / 87 mm diameter B04552
Clip for 100 ml flask, 12 flasks max. Clip for 100 ml flask, 12 flasks max. B02692
Clip for 200 ml flask, 6 flasks max. Clip for 200 ml flask, 6 flasks max. B02693
Clip for 300 ml flask, 6 flasks max. Clip for 300 ml flask, 6 flasks max. B02694
Clip for 500 ml flask, 5 flasks max. Clip for 500 ml flask, 5 flasks max. B02695
Rack for 110 test tubes 14.5 mm dia. Rack for 110 test tubes 14.5 mm dia. B02778
Rack for 90 test tubes 18 mm dia. Rack for 90 test tubes 18 mm dia. B02779
Rack for 25 test tubes 32 mm dia. B02780
Flat stainless steel cover with concentric ring sets for ring set openings: 8 openings / 107 mm diameter Flat stainless steel cover with concentric ring sets for ring set openings: 8 openings / 107 mm diameter B02684
Flat stainless steel cover with concentric ring sets for ring set openings: 4 openings / 147 mm diameter Flat stainless steel cover with concentric ring sets for ring set openings: 4 openings / 147 mm diameter B02685
Flat stainless steel cover with concentric ring sets for Peltier cooling CDP115: 8 openings / 107 mm diameter Flat stainless steel cover with concentric ring sets for Peltier cooling CDP115: 8 openings / 107 mm diameter B04462
Clip for 100 ml flask, 18 flasks max. Clip for 100 ml flask, 18 flasks max. B02692
Clip for 200 ml flask, 14 flasks max. Clip for 200 ml flask, 14 flasks max. B02693
Clip for 300 ml flask, 14 flasks max. Clip for 300 ml flask, 14 flasks max. B02694
Clip for 500 ml flask, 8 flasks max. Clip for 500 ml flask, 8 flasks max. B02695
Rack for 216 test tubes 14.5 mm dia. B04399
Rack for 180 test tubes 18 mm dia. B04400
Rack for 54 test tubes 32 mm dia. B04401
Reinforced stainless steel grid, max. loading 60 kg (only in connection with option K1) E20183 E20185
External control and logging package consisting of mini-Notebook and software „Celsius“, pre-configurated, and lateral swinging arm B04410
Stainless steel slide-in drip tray, 15 mm rim (may affect the temperature distribution) Stainless steel slide-in drip tray, 15 mm rim (may affect the temperature distribution) E02070 E02072 E02073
Stainless steel bottom drip tray, 15 mm rim (may affect the temperature distribution) Stainless steel bottom drip tray, 15 mm rim (may affect the temperature distribution) B04356 B04358 B04359
Additional perforated stainless steel shelf, full width Additional perforated stainless steel shelf, full width B00325 B00321 B03813
Additional stainless steel grid, full width Additional stainless steel grid, full width E20165 E20166 E29766
Additional water dish (half width model 246) Additional water dish (half width model 246) B02787 B02784 B02786
Subframe (622 mm high) Subframe (622 mm high) B02792 B02732 B02793
Subframe (130 mm hight for 2 stacked incubators) B02794 B02740 B02795
HEPA-filter for chamber according to EN 1822, packed in sterile condition, incl. fixing unit B04459
STERICard (additional or as replacement) for automatic chamber sterilisation cycle (not for sterilising load) E04337
CO2 pressure reducing valve DIN 8546, incl. Gas cylinder monitor E02087
N2 pressure reducing valve to DIN EN ISO 2503, incl. gas cylinder monitor (requires option T6) E06162
Central water supply with filter cartridges for connection to the domestic water supply, only in combination with option K7. Product information on demand ZWVR6
Central water supply without filter cartridges for connection to the domestic water supply (only for demineralised water in accordance with VDE 0510/DIN EN 50272), only in combination with option K7. Product information on demand ZWVR7
Celltron benchtop shaker (not subject to discount) – accessories upon request E06724
Additional perforated stainless steel shelve, half width B02742
Stainless steel slide-in drip tray, 15 mm rim (may affect the temperature distribution) - cannot be used in connection with option K1 E02070 E02072 E02073 E29726 E02075 B32599 E02068 B29726
Stainless steel bottom drip tray, 15 mm rim (may affect the temperature distribution) - cannot be used in connection with option K1 B04356 B04358 B04359 B29722 B04362 B29769 B04360
Guarantee extension by 1 year GA1Q5 GA2Q5 GA3Q5 GA4Q5
Module for external fresh water supply, only in combination with humidity module B04712
Stainless steel grid E20167 E20182 B04055
Flush-fit unit (stainless steel frame covering gap between oven and wall opening) – technical clarification necessary B03190 B03188
Loading set consisting of 8 grids,
as well as 16 spacers
- incl. 3 baskets for cups/glasses, made of
stainless steel material no. 1.4301 (ASTM 304) Loading set consisting of 8 grids, as well as 16 spacers - incl. 3 baskets for cups/glasses, made of stainless steel material no. 1.4301 (ASTM 304) B04105
USB connection cable for computer interface E03643
Temperature profile write/read unit for programming via PC, for writing to and reading from the chip card, up to 40 ramps E05284
Additional chip card, blank, formatted (32 kB MEMoryCard XL for a maximum of 40 ramps) E04004
Oven-linked authorisation card (User-ID-Card) prevents undesired manipulation by unauthorised third parties. When reordering please specify serial number E04159
Software conforming to FDA ”Celsius FDA Edition“ for up to 16 units. Meets the requirements for the use of electronically stored data sets and electronic signatures as laid down in Regulation 21 CFR Part 11 of the US Food and Drug Administration (FDA). Not applicable for UFP800DW E05019
Integration of additional units (up to max.16 units) into an already existent FDA-software licence. Not applicable for UFP800DW FDAQ4
IQ check list with works test data for chamber as support for validation by customer D00103
OQ check list with works test data for one free-selectable temperature value incl. temperature distribution survey for 27 measuring points to DIN 12880:2007-05 as support for validation by customer D00104 D00144
OQ check list with works test data for one free-selectable temperature and vacuum value incl. temperature distribution survey for 5 measuring points to DIN 12880:2007-05 as support for validation by customer (VO, VOcool only) valid for one thermoshelf, dito for further thermoshelves VO: EUR 340,– each D00117
OQ check list with works test data for one free-selectable humidity and temperature value incl. temperature distribution survey for 27 measuring points to DIN 12880:2007-05 as support for validation by customer (models HCP and CTC) D00104
OQ check list with works test data for one free-selectable CO2, humidity and temperature value incl. temperature distribution survey for 27 measuring points to DIN 12880:2007-05 as support for validation by customer (models INCOmed) D00104
External measuring instrument with sensors for daylight and UV-light, with additional measuring head for temperature and humidity. Product information on demand (models HCP and CTC) B04714
Test tube racks, 56 holes (7x8), dia.18 mm each, bath capacity: 1 rack Test tube racks, 56 holes (7x8), dia.18 mm each, bath capacity: 1 rack B02781
Test tube racks, 24 holes (3x8), dia.18 mm each, bath capacity: 2 racks Test tube racks, 24 holes (3x8), dia.18 mm each, bath capacity: 2 racks B02783
Test tube rack, holes 2-row racks, 40 holes, dia. 10 mm each, width 40 mm Test tube rack, holes 2-row racks, 40 holes, dia. 10 mm each, width 40 mm E02028
Test tube rack, holes 2-row racks, 40 holes, dia. 12 mm each, width 40 mm Test tube rack, holes 2-row racks, 40 holes, dia. 12 mm each, width 40 mm E02013
Test tube rack, holes 2-row racks, 24 holes, dia. 14.5 mm each, width 43 mm Test tube rack, holes 2-row racks, 24 holes, dia. 14.5 mm each, width 43 mm E02014
Test tube rack, holes 2-row racks, 24 holes, dia. 18 mm each, width 50 mm Test tube rack, holes 2-row racks, 24 holes, dia. 18 mm each, width 50 mm E02022
Test tube rack, holes 2-row racks, 20 holes, dia. 21 mm each, width 55 mm Test tube rack, holes 2-row racks, 20 holes, dia. 21 mm each, width 55 mm E02032
Test tube rack, holes 2-row racks, 12 holes, dia. 32 mm each, width 80 mm Test tube rack, holes 2-row racks, 12 holes, dia. 32 mm each, width 80 mm E02034
Test tube rack, holes 3-row racks, 60 holes, dia. 10 mm each, width 50 mm Test tube rack, holes 3-row racks, 60 holes, dia. 10 mm each, width 50 mm E02046
Test tube rack, holes 3-row racks, 60 holes, dia. 12 mm each, width 55 mm Test tube rack, holes 3-row racks, 60 holes, dia. 12 mm each, width 55 mm E02049
Test tube rack, holes 3-row racks, 36 holes, dia. 14.5 mm each, width 60 mm Test tube rack, holes 3-row racks, 36 holes, dia. 14.5 mm each, width 60 mm E02039
Test tube rack, holes 3-row racks, 36 holes, dia. 18 mm each, width 70 mm Test tube rack, holes 3-row racks, 36 holes, dia. 18 mm each, width 70 mm E02019
Test tube rack, holes 3-row racks, 30 holes, dia. 21 mm each, width 80 mm Test tube rack, holes 3-row racks, 30 holes, dia. 21 mm each, width 80 mm E02043
Test tube rack, holes 4-row racks, 80 holes, dia. 10 mm each, width 64 mm Test tube rack, holes 4-row racks, 80 holes, dia. 10 mm each, width 64 mm E02057
Test tube rack, holes 4-row racks, 80 holes, dia. 12 mm each, width 75 mm Test tube rack, holes 4-row racks, 80 holes, dia. 12 mm each, width 75 mm E02060
Test tube rack, holes 4-row racks, 48 holes, dia. 14.5 mm each, width 85 mm Test tube rack, holes 4-row racks, 48 holes, dia. 14.5 mm each, width 85 mm E02056
Test tube rack, holes 4-row racks, 48 holes, dia. 18 mm each, width 95 mm Test tube rack, holes 4-row racks, 48 holes, dia. 18 mm each, width 95 mm E02051
Test tube rack, holes 4-row racks, 40 holes, dia. 21 mm each, width 110 mm Test tube rack, holes 4-row racks, 40 holes, dia. 21 mm each, width 110 mm E02061
USB-Ethernet adapter E06192
Ethernet connection cable 5 m for computer interface E06189
USB User-ID stick (with User-ID licence): Oven-linked authorisation licence (User-ID-programme) on Memory-stick, prevents undesired manipulation by unauthorised third parties. When reordering please specify serial number (only for units with TwinDISPLAY) B33170
USB stick with documentation software AtmoCONTROL and operation manual for products with SingleDISPLAY (the standard equipment of appliances with TwinDISPLAY includes one USB stick with AtmoCONTROL) B33172
Set of height adjustable feet (4 pcs). Standard on models ICOmed B29768
Stacking set (4 pcs) for stacking of appliances of same size (not for models 160, 260, 450, 750, 1060, ICH110, ICH110L and ICH110C) Stacking set (4 pcs) for stacking of appliances of same size (not for models 160, 260, 450, 750, 1060, ICH110, ICH110L and ICH110C) B29744
Plug-in tube extension (outer diam. 60,3 mm, inner 57 mm), straight, for exhaust air ducting (if necessary for connection by hose), only models U, I, S Plug-in tube extension (outer diam. 60,3 mm, inner 57 mm), straight, for exhaust air ducting (if necessary for connection by hose), only models U, I, S B29718
Plug-in tube extension (outer diam. 60,3 mm, inner 57 mm), angled, for exhaust air ducting (if necessary for connection by hose), only models U, I, S Plug-in tube extension (outer diam. 60,3 mm, inner 57 mm), angled, for exhaust air ducting (if necessary for connection by hose), only models U, I, S B29719
Flush-fit unit (stainless steel frame covering gap between oven and wall opening), with air slots – technical clarification required Flush-fit unit (stainless steel frame covering gap between oven and wall opening), with air slots – technical clarification required B29728 B42116 B29742 B29743 B29738 B29740 B29730 B29732 B29734 B29736
Flush-fit unit (stainless steel frame covering gap between oven and wall opening), without air slots – technical clarification required Flush-fit unit (stainless steel frame covering gap between oven and wall opening), without air slots – technical clarification required B29729 B42117 B29743 B33204 B33205 B33206 B33207 B29735 B29739 B29741 B29731 B29733 B29737
Subframe, adjustable in height (size 30 to 75: height 600 mm, size 110 to 450: height 500 mm) Subframe, adjustable in height (size 30 to 75: height 600 mm, size 110 to 450: height 500 mm) B29745 B29749 B29751 B29747 B29753
Subframe, on castors (size 30 to 75: height 660 mm, size 110 to 160: height 560 mm) Subframe, on castors (size 30 to 75: height 660 mm, size 110 to 160: height 560 mm) B29746 B29750 B29748
Subframe, adjustable in height (height 130 mm, for example for units with fresh-air filter) B33657 B33661 B33664 B33659
Software conforming to FDA “AtmoCONTROL“. Meets the requirements for the use of electronically stored data sets and electronic signatures as laid down in Regulation 21 CFR Part 11 of the US Food and Drug Administration (FDA). Base licence for the control of one unit (only for units with TwinDISPLAY). Respective IQ/OQ documents available in German and English language (without surcharge). FDAQ1
Integration of one additional unit (up to max. 15 units) into an already existent FDA-software licence FDAQ2
IQ document with device-specific works test data, OQ/PQ check list as support for validation by customer D00124
IQ/OQ document with works test data for chamber, incl. temperature distribution survey for one free-selectable temperature value. 9 measuring points (size 30), 27 measuring points (sizes 55 - 1060) to DIN 12880:2007-05 (further temperature values on demand), PQ check list as support for validation by customer D00125 D00127
IQ/OQ document with device-specific works test data for one free-selectable temperature and humidity value, incl. temperature distribution survey at Memmert for 27 measuring points (26 measuring points on model HPP1400) to DIN 12880:2007-05, PQ check list as support for validation by customer (models HPP and ICH). D00136 D00127
IQ/OQ document with works test data for chamber, incl. temperature distribution survey for one free-selectable temperature, humidity and light value. 27 measuring points to DIN 12880:2007-05, PQ check list as support for validation by customer (models HPP with light and ICH L) D00137
External measuring instrument with sensors for daylight and UV-light. Product information on demand (models HPP, ICH L, IPPplus) B04713
External measuring instrument with sensors with additional measuring head for temperature and humidity measurement. Product information on demand (models HPP, ICH, ICH L, ICH C, IPPplus and ICOmed) B04714

Order No.
Additional reinforced perforated stainless steel shelf, max. loading 60 kg; with guide bars and fixing screws (only in connection with option K1). Please consider max. loading of chamber B32191