Options / Accessories

for Vacuum Ovens VO29

Digital pressure control ensures rapid and gentle vacuum drying, its speed-controlled vacuum pump (accessory) saves around 70% energy.

Option

Option Order No.
Premium module: comprises the inert gas inlet (only size 49 and 101), extra connectors for thermoshelves, 1 (size 29), 2 (sizes 49/101), an additional thermoshelf (sizes 49/101) T5
4 – 20 mA current loop interface (only with option T5) Temperature of a Pt100 sensor positioned flexibly in chamber for external temperature monitoring - price per sensor V6
Potential-free contact (24 V/2 A) with socket, according to NAMUR NE 28 for combination error message (e.g. supply failure, sensor fault, fuse) H6
MobileALERT, notification by SMS in case of any error or alarm of the device. Requires option H6 “floating contact for alarm” C3
Works calibration certificate for one (freely selectable) temperature and pressure value (per thermoshelf) according to customer specification D00116

Accessory

Accessory Order No.
Additional thermoshelves – aluminium eloxadised material W.-St. 3.3547 (ASTM B209) with integrated large-area heating including local temperature sensing (Pt100, 4-wire-circuit), individual overtemp. protection for each shelf MLOP (Multi-Level-Overtemperature-Control) and calibration certificate B00741
Additional thermoshelves – stainless steel material 1.4404 (ASTM 316 L) for especially corrosive material with integrated large-area heating including local temperature sensing (Pt100, 4-wire-circuit), individual overtemp. protection for each shelf MLOP (Multi-Level-Overtemperature-Control) and calibration certificate Additional thermoshelves – stainless steel material 1.4404 (ASTM 316 L) for especially corrosive material with integrated large-area heating including local temperature sensing (Pt100, 4-wire-circuit), individual overtemp. protection for each shelf MLOP (Multi-Level-Overtemperature-Control) and calibration certificate B00733
Subframe, tubular steel, black enamelled (for stacking unit consisting of vacuum oven and pump module, total height: 1650 mm, see "further data" and sketch of oven dimensions) E02030
Works calibration certificate for 3 temperatures: +50 °C, +100 °C, +160 °C at 20 mbar pressure. Price per thermoshelf D00115
Guarantee extension by 1 year GA2Q5
Noise-insulated vacuum pump module, as above, however with built-in pump, 230 V, 50/60 Hz PMP29
Noise-insulated vacuum pump module without pump (exterior dimensions and -material No. s. vacuum oven) with antivibration metal plate at the bottom to accommodate the vacuum pump, incl. full-sight glass door. Socket, signal cable and connecting hose to the vacuum oven PM29
Signal cable (3 m) for control of roation speed and optimising pump performance by demand-controlled activation of purge of Memmert pump (not required with pump module) B39410
Vacuum connecting hose (3 m) from oven to Memmert pump incl. optimised connection accessories (partially stainless steel) Vacuum connecting hose (3 m) from oven to Memmert pump incl. optimised connection accessories (partially stainless steel) B04026
Vacuum pump with chemically resistant 4x diaphragm, pump capacity at atm. pressures: approx. 50 Nl./min = 3,0 m/h3 and autom. purge control. Order No. B39410 and B04026 necessary. 230 V, 50 Hz. Max. guarantee period 2 years E07509
USB-Ethernet adapter E06192
Ethernet connection cable 5 m for computer interface E06189
USB User-ID stick (with User-ID licence): Oven-linked authorisation licence (User-ID-programme) on Memory-stick, prevents undesired manipulation by unauthorised third parties. When reordering please specify serial number B33170
Integration of one additional unit (up to max. 31 units) into an already existent FDA-software licence FDAQ2
FDA conforming software AtmoCONTROL (FDA edition). Meets the requirements for the use of electronically stored data sets and electronic signatures as laid down in Regulation 21 CFR Part 11 of the US Food and Drug Administration (FDA). Base licence for the control of one unit. Respective IQ/OQ documents available in German and English language (without surcharge) FDAQ1
IQ document with device-specific works test data, OQ/PQ check list as support for validation by customer D00124
IQ/OQ document with device-specific works test data for one free-selectable temperature and vacuum value, incl. temperature distribution survey at Memmert for 5 measuring points per thermoshelf to DIN 12880:2007-05. PQ check list as support for validation by customer valid for one thermoshelf; dito further thermoshelves, price on demand. D00117
Individual on-site Performance Qualification (PQ) DLQ200
Maintenance contract VO - carrying out and documentation according to Memmert maintenance plan, minimum duration 3 years (excluding travel costs, not subject to discount, GER, AT, FR only) S00320J
Calibration of an additional temperature value (not subject to discount) S00215
Extension of DLQ106 by an additional freely selectable temperature and pressure value (each thermoshelf) (not subject to discount) DLQ106A
Extension of DLQ106 by a further thermoshelf for a freely selectable temperature and pressure value (not subject to discount) DLQ106T
On-site IQ/OQ for a freely selectable temperature and pressure value of a thermoshelf, including temperature distribution survey for 5 measuring points to DIN 12880: 2007-05 (excluding travel costs, not subject to discount, GER, AT, FR only) DLQ106
Calibration of one freely selectable temperature value (excluding travel costs, not subject to discount, GER, AT, CH, FR only) S00205
Calibration of an additional temperature and pressure value (not subject to discount) S00218
Calibration of one freely selectable temperature and pressure value (excluding travel costs, not subject to discount, GER, AT, FR only) S00212