Options / Accessories

for Vacuum Ovens VO49

Digital pressure control ensures rapid and gentle vacuum drying, its speed-controlled vacuum pump (accessory) saves around 70% energy.

Option

Option Order No.
Premium module: comprises the inert gas inlet (only size 49 and 101), extra connectors for thermoshelves, 1 (size 29), 2 (sizes 49/101), an additional thermoshelf (sizes 49/101) T5
4 – 20 mA current loop interface (only with option T5) Vacuum actual value (0 bis 1200 mbar = 4 - 20) W2
4 – 20 mA current loop interface (only with option T5) Temperature actual value (0 to 210 °C = 4 - 20 m) V3
4 – 20 mA current loop interface (only with option T5) Temperature of a Pt100 sensor positioned flexibly in chamber for external temperature monitoring - price per sensor V6
Works calibration certificate for 3 temperatures: +50 °C, +100 °C, +160 °C at 20 mbar pressure. Price per thermoshelf D00115
Works calibration certificate for one (freely selectable) temperature and pressure value (per thermoshelf) according to customer specification D00116
Freely positioned control sensor, MIN and MAX alarm adjustable at ControlCOCKPIT, alarm values captured in internal data logger H9
Potential-free contact (24 V/2 A) with socket, according to NAMUR NE 28, triple, for signal generation, controlled by programme segment for a total of one freely selected function to be activated (e.g. acoustic and visual signals, exhaust motors, fans, stirrers etc.) Potential-free contact (24 V/2 A) with socket, according to NAMUR NE 28, triple, for signal generation, controlled by programme segment for a total of one freely selected function to be activated (e.g. acoustic and visual signals, exhaust motors, fans, stirrers etc.) H7
Potential-free contact (24 V/2 A) with socket, according to NAMUR NE 28 for combination error message (e.g. supply failure, sensor fault, fuse) H6
Flexible Pt100 for positioning in chamber or in load with socket, 4-pin, according to NAMUR NE 28, for external temperature recording (load temperature) H4
MobileALERT for 2 alarm notifications; temperature and vacuum alarm (only with option T5) C4
MobileALERT, notification by SMS in case of any error or alarm of the device. Requires option H6 “floating contact for alarm” C3
Temperature restriction; Temperatures: +60, +70, +80, +95, +100, +120, +160 or +180 °C (Please, indicate upon ordering) A8

Accessory

Accessory Order No.
Guarantee extension by 1 year GA2Q5
Noise-insulated vacuum pump module, as above, however with built-in pump, 230 V, 50/60 Hz PMP49
Noise-insulated vacuum pump module without pump (exterior dimensions and -material No. s. vacuum oven) with antivibration metal plate at the bottom to accommodate the vacuum pump, incl. full-sight glass door. Socket, signal cable and connecting hose to the vacuum oven PM49
Signal cable (3 m) for control of roation speed and optimising pump performance by demand-controlled activation of purge of Memmert pump (not required with pump module) B39410
Vacuum connecting hose (3 m) from oven to Memmert pump incl. optimised connection accessories (partially stainless steel) Vacuum connecting hose (3 m) from oven to Memmert pump incl. optimised connection accessories (partially stainless steel) B04026
Vacuum pump with chemically resistant 4x diaphragm, pump capacity at atm. pressures: approx. 50 Nl./min = 3,0 m/h3 and autom. purge control. Order No. B39410 and B04026 necessary. 230 V, 50 Hz. Max. guarantee period 2 years E07509
USB-Ethernet adapter E06192
Ethernet connection cable 5 m for computer interface E06189
USB User-ID stick (with User-ID licence): Oven-linked authorisation licence (User-ID-programme) on Memory-stick, prevents undesired manipulation by unauthorised third parties. When reordering please specify serial number B33170
Additional thermoshelves – aluminium eloxadised material W.-St. 3.3547 (ASTM B209) with integrated large-area heating including local temperature sensing (Pt100, 4-wire-circuit), individual overtemp. protection for each shelf MLOP (Multi-Level-Overtemperature-Control) and calibration certificate B00743
Additional thermoshelves – stainless steel material 1.4404 (ASTM 316 L) for especially corrosive material with integrated large-area heating including local temperature sensing (Pt100, 4-wire-circuit), individual overtemp. protection for each shelf MLOP (Multi-Level-Overtemperature-Control) and calibration certificate Additional thermoshelves – stainless steel material 1.4404 (ASTM 316 L) for especially corrosive material with integrated large-area heating including local temperature sensing (Pt100, 4-wire-circuit), individual overtemp. protection for each shelf MLOP (Multi-Level-Overtemperature-Control) and calibration certificate B00734
Subframe, tubular steel, black enamelled (for stacking unit consisting of vacuum oven and pump module, total height: 1650 mm, see "further data" and sketch of oven dimensions) E02031
Integration of one additional unit (up to max. 15 units) into an already existent FDA-software licence FDAQ2
IQ/OQ document with device-specific works test data for one free-selectable temperature and vacuum value, incl. temperature distribution survey at Memmert for 5 measuring points per thermoshelf to DIN 12880:2007-05. PQ check list as support for validation by customer valid for one thermoshelf; dito further thermoshelves, price on demand. D00117
Software conforming to FDA AtmoCONTROL. Meets the requirements for the use of electronically stored data sets and electronic signatures as laid down in Regulation 21 CFR Part 11 of the US Food and Drug Administration (FDA). Base licence for the control of one unit. Respective IQ/OQ documents available in German and English language (without surcharge) FDAQ1
IQ document with device-specific works test data, OQ/PQ check list as support for validation by customer D00124