Options / Accessories

for Waterbath WTB24

Ideal for the temperature control of ointments, emulsions, samples, plates and nutrient solutions in the laboratory, as well as warm storage and calibration in the industrial segment

Option

Option Order No.
Voltage 115 V, 50/60 Hz (no extra cost) X2
Works calibration certificate for 37 °C D00123

Accessory

Accessory Order No.
Flat stainless steel cover with openings and concentric ring sets; 6 openings, Ø 107 mm B48808
Flat stainless steel cover with openings and concentric ring sets; 6 openings, Ø 107 mm B48805
Shelf reversible for 2 heights (30 or 60 mm) Shelf reversible for 2 heights (30 or 60 mm) E48811
Peltier-cooling device CDP115 for waterbaths for temperatures below ambient from +10 °C, Voltage 230 V, 50/60 Hz. Please do not forget to order the installation and connection set (B48813)! CDP115
Peltier-cooling device CDP115 for waterbaths for temperatures below ambient from +10 °C, Voltage 115 V 60 Hz. Please do not forget to order the installation and connection set (B48813)! CDP115X2
Pump device for continuous circulation of the tempering medium. Voltage 230 V, 50/60 Hz. Please do not forget to order the installation and connection set (B48838) CPM650
Installation and connection set for pump device CPM650 (incl. mounting bars for all different bath sizes) B48838
Shaking device for waterbaths incl. support frame, shaking frequency 35 - 160 strokes per minute (horizontal back/forth movement), requires gable cover. Voltage 230 V, 50/60 Hz. Please do not forget to order the support basket. SV1524
Shaking device for waterbaths incl. support frame, shaking frequency 35 - 160 strokes per minute (horizontal back/forth movement), requires gable cover. Voltage 115 V, 60 Hz. Please do not forget to order the support basket. SV1524X2
Support basket with perforated mounting shelf (stainless steel) with grid perforations to take clips for conical flasks (use of test tube racks not possible) Support basket with perforated mounting shelf (stainless steel) with grid perforations to take clips for conical flasks (use of test tube racks not possible) B48814
Rack for 110 test tubes 14.5 mm dia. Rack for 110 test tubes 14.5 mm dia. B48816
Rack for 90 test tubes 18 mm dia. Rack for 90 test tubes 18 mm dia. B48818
Rack for 25 test tubes 32 mm dia. B48820
Clip for 100 ml flask, max. flasks see sketch B02692
Clip for 200 ml flask, max. flasks see sketch B02693
Clip for 300 ml flask, max. flasks see sketch B02694
Clip for 500 ml flask, max. flasks see sketch B02695
Test tube racks, holes 2-row racks, 40 holes, Ø 10 mm each (transverses for sizes 15 and 24) B48822
Test tube racks, holes 2-row racks, 40 holes, Ø 10 mm each (longitudinals for sizes 15 and 24) B48823
Test tube racks, holes 2-row racks, 40 holes, Ø 12 mm each (transverses for sizes 15 and 24) B48824
Test tube racks, holes 2-row racks, 40 holes, Ø 12 mm each (longitudinals for sizes 15 and 24) B48825
Test tube racks, holes 2-row racks, 24 holes, Ø 14.5 mm each (transverses for sizes 15 and 24) B48826
Test tube racks, holes 2-row racks, 24 holes, Ø 14.5 mm each (longitudinals for sizes 15 and 24) B48827
Test tube racks, holes 2-row racks, 24 holes, Ø 18 mm each (transverses for sizes 15 and 24) B48828
Test tube racks, holes 2-row racks, 24 holes, Ø 18 mm each (longitudinals for sizes 15 and 24) B48829
Test tube racks, holes 2-row racks, 20 holes, Ø 21 mm each, width 57 mm (transverses for sizes 15 and 24) B48830
Test tube racks, holes 2-row racks, 20 holes, Ø 21 mm each, width 57 mm (longitudinals for sizes 15 and 24) B48831
Test tube racks, holes 2-row racks, 12 holes, Ø 32 mm each (transverses for sizes 15 and 24) B48832
Test tube racks, holes 2-row racks, 12 holes, Ø 32 mm each (longitudinals for sizes 15 and 24) B48833
Test tube racks, holes 3- row racks, 36 holes, Ø 18 mm each (longitudinals for sizes 15 and 24) B48835
Test tube racks, holes 4-row racks, 48 holes, Ø 18 mm each (transverses for sizes 15 and 24) B48836
Test tube racks, holes 3- row racks, 36 holes, Ø 18 mm each (transverses for sizes 15 and 24) B48834
Test tube racks, holes 4-row racks, 48 holes, Ø 18 mm each (longitudinals for sizes 15 and 24) B48837
Installation and connection set for Peltier cooling device CDP115 (incl. mounting bars for all different bath sizes) B48813
IQ/OQ document with device-specific works test data for one freeselectable temperature value, incl. temperature distribution survey at Memmert for 9 measuring points to DIN 12876.2. Further temperature values and validation at customer site on demand. D00125
Stainless steel gable cover B39845
Maintenance WTB - carrying out and documentation according to Memmert maintenance plan (excluding travel costs, not subject to discount, GER, AT, CH, FR only) S00321
Maintenance contract WTB - carrying out and documentation according to Memmert maintenance plan, minimum duration 3 years (excluding travel costs, not subject to discount, GER, AT, CH, FR only) S00321J
Calibration of one freely selectable temperature value (excluding travel costs, not subject to discount, GER, AT, CH, FR only) S00205
Calibration of an additional temperature value (not subject to discount) S00215