Constant climate chamber HPP260

Our constant climate chamber is tailored to environmental simulation, material testing and stability testing in accordance with the ICH guidelines.

HPP260

Constant climate chamber HPP260

Standard delivery Constant climate chamber

On this page, you can find all the essential technical data on the Memmert stability chamber HPP. Our customer relations team will be pleased to help if you want further information. If you should require a customised special solution, please contact our technical specialists at myAtmoSAFE@memmert.com.

Sketch Constant climate chamber HPP260

Properties

Control of standard components

ControlCOCKPIT adaptive multifunctional digital PID-microprocessor controller with 2 high-definition TFT-colour displays
Temperature 2 Pt100 sensors Class A in 4-wire-circuit, mutually monitoring and taking over the performance at the same temperature value
Humidity humidity supply with distilled water from external tank by self-priming pump
Humidity humidity supply with distilled water from external tank by self-priming pump
Humidity humidification by hot steam generator
Humidity active humidifying and de-humidifying adjustable from 10 - 90 % rh with digital display of relative humidity - resolution of display 0.1 %, setting accuracy 0.5 %
Humidity dehumidification by cold trap using the Peltier technology
Timer Digital backwards counter with target time setting, adjustable from 1 minute to 99 days

Temperature

without light: from 0°C to +70°C
with light: from +15°C to +40°C
resolution of display for setpoint and actual temperature values 0.1°C

Control technology

Function HeatBALANCE adapting the distribution of the heating performance of the upper and lower heating circuit from -50 % to +50 %
Function SetpointWAIT the process time does not start until the set temperature is reached
Language setting German/English/Spanish/French
Calibration three freely selectable temperature values, 2-point calibration for humidity: 20 and 90 % rh
adjustable parameters temperature (Celsius or Fahrenheit), relative humidity, programme time, time zones, summertime/wintertime

Ventilation

forced ventilation by Peltier fan

Communication

Documentation programme stored in case of power failure
Programming AtmoCONTROL software on a USB stick for programming, managing and transferring programmes via Ethernet interface or USB port

Safety

Temperature control over- and undertemperature monitor TWW, protection class 3.3 or adjustable temperature limiter TWB, protection class 2, selectable on display
AutoSAFETY additionally integrated over- and undertemperature protection "ASF", automatically following the setpoint value at a preset tolerance range, alarm in case of over- or undertemperature, heating function is switched off in case of overtemperature, cooling function in case of undertemperature
Autodiagnostic system integral fault diagnostics for temperature and humidity control
Alarm visual and acoustic

Heating concept

Heating and cooling performance distribution by individual control of the Peltier elements in the upper and lower row
energy-saving Peltier heating-/cooling system integrated in the rear (heat pump principle)

Standard equipment

Door fully insulated stainless steel door with 2-point locking (compression door lock)
Door inner glass door
Housing rear zinc-plated steel
Internals 2 stainless steel grids

Stainless steel interior

Max. loading of chamber: 200 kg
Dimensions W x H x D in mm w(A) x h(B) x d(C): 640 x 800 x 500 mm
Volume 256 l

Textured stainless steel casing

w(D) x h(E) x d(F): 824 x 1183 x 774 mm

Electrical data

Voltage Electrical load 230 V, 50/60 Hz
approx. 920 W
Voltage Electrical load 115 V, 50/60 Hz
approx. 920 W

Packing/shipping data

the appliances must be transported upright
Customs tariff number 8419 8998
Country of origin Federal Republic of Germany
WEEE-Reg.-No. DE 66812464
Dimensions approx incl. carton B x H x T: 930 x 1380 x 930 mm
Net weight approx. 122 kg
Gross weight carton approx. 173 kg

More product series of Climate chambers

Humidity chamber

Humidity chamber

High-precision control technology creates controlled and physiologically ideal surroundings for the perfect environment simulation in building physics, electronics, biology, zoology and botany.

Climate chamber

Climate chamber

Unparalleled homogeneity of temperature and humidity! For stability testing according to ICH - WHO - EMA - ASEAN - GMP - GLP – GCCP.

Climate chamber for keeping mice

Climate chamber for keeping mice

„Specific Pathogen Free” (SPF) keeping of mice and rats in compliance with GV Solas guidelines.

Environmental test chambers

Environmental test chambers

Memmert environmental test chambers guarantee the perfect atmosphere for climate and temperature tests

More product categories

Heating / drying ovens

Incubators

Water and oilbaths