Memmert - a reliable partner in medicine

It is our hard-lined commitment to quality that has made Memmert a reliable partner in the medical sector and medical research industry ever since the company’s founding in 1947. Of course we are DIN EN ISO 13485 certified since many years. The following products are classified as medical device. Memmert is bringing medical devices of class I according to the regulation MDR (EU) 2017/745 into circulation. Memmert is bringing medical devices of class IIa and IIb into circulation according to MDD 93/42/EEC until 26 May 2024 according to the transitional provisions by the (EU) 2017/745 article 120 (2).

Incubator Im

The incubator Im is a Class I medical device.

Incubator I with natural air circulation (convection) TwinDISPLAY IN110plus 745 x 864 x 584 mm
Classified medical device

Temper rinsing and infusion solutions and contrast media
Incubator Im as a medical device

Incubators Im and Implus may be used for temperature control of rinsing, infusion solutions, and contrast agents. With the fine-tuned control technology, critical temperature overshoots are completely ruled out. Rinsing and infusion solutions are therefore heated precisely and particularly gently in this high-precision incubator. Memmert in cubator Im is bringing medical devices of class I according to the regulation MDR (EU) 2017/745 into circulation.

Memmert incubator I – a gentle force in the laboratory

The unique all-round surface heating that the Memmert incubator Im features is perfect for both natural convection and forced air circulation. The fan can be switched off completely – without affecting the optimum temperature distribution.

A Memmert incubator offers unique advantages

  • intuitive and easy-to-use operating menu
  • air exchange rates and air flap position electronically controllable
  • temperature ramps programmable via AtmoCONTROL software (models with TwinDISPLAY)
  • pre-heated fresh air prevents temperature fluctuations
  • almost exclusive use of high-quality, corrosion-resistant and easily cleanable stainless steel for the working chamber and housing
  • heating concept specifically adapted for a precise and homogenous temperature control
  • a wide range of options for reading the data logging using interfaces, integrated data logger and software AtmoCONTROL
  • 3 years guarantee worldwide

Standard units are safety-approved and bear the test marks

CE
VDE
UL

Models

Size
Performance Class
Show more
SingleDISPLAY SingleDISPLAY for basic applications Temperature, air flap and fan remain unchanged during the whole process
Show more
TwinDISPLAY TwinDISPLAY Maximum comfort for complex processes For many years to come the equipment of Memmert's model variant TwinDISPLAY will leave nothing to be desired regarding function range, convenience and safety.
Air Circulation
Description Performance Class Air Circulation
IN30m IN30m SingleDISPLAY Natural air circulation (Convection) Details
IN30mplus IN30mplus TwinDISPLAY Natural air circulation (Convection) Details
IF30m IF30m SingleDISPLAY Forced air circulation (Fan) Details
IF30mplus IF30mplus TwinDISPLAY Forced air circulation (Fan) Details
IN55m IN55m SingleDISPLAY Natural air circulation (Convection) Details
IN55mplus IN55mplus TwinDISPLAY Natural air circulation (Convection) Details
IF55m IF55m SingleDISPLAY Forced air circulation (Fan) Details
IF55mplus IF55mplus TwinDISPLAY Forced air circulation (Fan) Details
IN75m IN75m SingleDISPLAY Natural air circulation (Convection) Details
IN75mplus IN75mplus TwinDISPLAY Natural air circulation (Convection) Details
IF75m IF75m SingleDISPLAY Forced air circulation (Fan) Details
IF75mplus IF75mplus TwinDISPLAY Forced air circulation (Fan) Details
IN110m IN110m SingleDISPLAY Natural air circulation (Convection) Details
IN110mplus IN110mplus TwinDISPLAY Natural air circulation (Convection) Details
IF110m IF110m SingleDISPLAY Forced air circulation (Fan) Details
IF110mplus IF110mplus TwinDISPLAY Forced air circulation (Fan) Details
IN160m IN160m SingleDISPLAY Natural air circulation (Convection) Details
IN160mplus IN160mplus TwinDISPLAY Natural air circulation (Convection) Details
IF160m IF160m SingleDISPLAY Forced air circulation (Fan) Details
IF160mplus IF160mplus TwinDISPLAY Forced air circulation (Fan) Details
IN260m IN260m SingleDISPLAY Natural air circulation (Convection) Details
IN260mplus IN260mplus TwinDISPLAY Natural air circulation (Convection) Details
IF260m IF260m SingleDISPLAY Forced air circulation (Fan) Details
IF260mplus IF260mplus TwinDISPLAY Forced air circulation (Fan) Details
IN450m IN450m SingleDISPLAY Natural air circulation (Convection) Details
IN450mplus IN450mplus TwinDISPLAY Natural air circulation (Convection) Details
IF450m IF450m SingleDISPLAY Forced air circulation (Fan) Details
IF450mplus IF450mplus TwinDISPLAY Forced air circulation (Fan) Details
IN750m IN750m SingleDISPLAY Natural air circulation (Convection) Details
IN750mplus IN750mplus TwinDISPLAY Natural air circulation (Convection) Details
IF750mplus IF750mplus TwinDISPLAY Forced air circulation (Fan) Details
IF750m IF750m SingleDISPLAY Forced air circulation (Fan) Details

Intended use as medical device

Memmert is bringing medical devices of class I according to EU Directive 93/42/EEC into circulation until the regulation MDR (EU) 2017/745 comes into force. After the new regulation comes into force, Memmert will bring medical devices of class I into circulation according to MDR.

Type Intended use as medical device Classification according to MDD
UNmplus, UFmplus The appliance may be used for heating fango, silicate and APS packs for physical therapy and keeping them warm. I
UNm, UFm, INm, IFm The appliance may be used for heating fango, silicate and APS packs for physical therapy and keeping them warm. I
INmplus, IFmplus The appliance may be used for temperature control of rinsing and infusion solutions and contrast agents. I
IFbw The appliance may be used for heating non-sterile covers and cloths. I

Memmert is bringing medical devices of class IIa and IIb into circulation according to MDD 93/42/EEC until 26 May 2024 according to the transitional provisions by the (EU) 2017/745 article 120 (2).

Type Intended use as medical device Classification according to MDD
SNplus, SFplus The product is intended for the sterilisation of medical devices with dry heat at atmospheric pressure. IIb
SN, SF The product is intended for the sterilisation of medical devices with dry heat at atmospheric pressure. IIb
ICOmed The appliance is intended for the creation and maintenance of constant environmental conditions for application in the field of in vitro fertilisation (IVF), especially for the incubation of oocytes, spermatozoa and zygotes in special culture dishes for IVF application as well as for gene expression and the biosynthesis of RNA and proteins. IIa

Download as pdf

Medical device consultant training

As part of our medical device consultant training, we qualify you in the consultation, use and instruction of our medical products, taking into account the currently applicable legal requirements with regard to the new Medical Devices Regulation (EU) 2017/745. We explain the requirements for dealers, the geographical scope as well as information on the reporting system and the tasks of a medical device consultant. After successful participation, you will receive a certificate of qualification as a medical device consultant for Memmert medical devices.

Have we piqued your interest? Please contact us at sales@memmert.com for more information.