U-BTC

Battery test chamber

Designed for thermal battery testing.
Engeneered for safety in applications up to hazard level 4.

The Memmert U-BTC battery test chamber was specifically developed for thermal battery testing up to Hazard Level 4, combining precise temperature control with integrated safety features for reliable test conditions.

Designed for safe battery testing

Why it matters

Battery testing requires more than precise temperature control. Heat generated by the battery, the test procedure and potential failure scenarios all need to be considered when creating a reliable test environment.

Designed specifically for thermal battery testing up to Hazard Level 4, the U-BTC provides reliable conditions for testing at elevated temperatures.

Its temperature range from +20 to +120 °C covers a wide range of thermal battery testing requirements.

Its integrated safety concept combines pressure relief, mechanical door locking and process-dependent electronic locking.

For your battery testing

The U-BTC is designed for thermal battery testing from individual cells to complete battery systems. It supports a wide range of applications in development, validation and quality assurance, including test tasks related to standards such as IEC 62660, IEC 62619 and ISO 12405-4.

Typical users

  • Battery cell manufacturers
  • Automotive OEMs and suppliers
  • Energy storage providers
  • Test laboratories
  • Research institutions
Safety Features Come Standard

Key battery-specific safety features are built in from the start and require no separate configuration or ordering.

  • Pressure relief
  • Mechanical door locking
  • Process-dependent electronic locking
  • Door-open recognition
  • Interior nearly gastight
  • Signal lights for device status
  • Temperature restriction to +120 °C

Standards in Focus

The U-BTC supports typical thermal test tasks in the context of relevant battery standards. Which test procedures can be supported in a specific application depends on the battery under test, the required test conditions and the selected U-BTC model.

 

Download the brochure

The Eucar Hazard Levels

Hazard Levels indicate how a battery may react during testing. The Memmert U-BTC is designed for applications up to Hazard Level 4 and must not be used for applications at Hazard Level 5 or higher.

Hazard
level
Description Effect on the battery cell
Visual / acoustic alarm
Temperature limiter
Tmax
Electrical door lock
Mechanical door securing
Reversible pressure relief flap
Fire detection
CO₂ measurement
CO₂ / N₂ purging system
Continuous N₂ inerting / O₂ measurement
Overpressure relief / rupture disc
0 No effect No effect.
No impairment of functionality.
☒
1 Protection system
activates
No defect. Cell recoverable; protection
system repair required.
☒ ☒
2 Defect, damage Cell damaged. Repair required. ☒ ☒ ☒
3 Leak,
mass loss < 50%
Electrolyte loss, no venting,
no flame or fire.
☒ ☒ ☒ ☒
4 Gas release,
mass loss > 50%
Electrolyte loss, cell venting,
no flame or fire.
☒ ☒ ☒ ☒ ☒
5 Fire or flame No rupture, no explosion, no flying parts. □ □ □ □ □ □ □
6 Rupture No explosion, no flying parts. □ □ □ □ □ □ □ □
7 Explosion Explosion, destruction within a very
short time
□ □ □ □ □ □ □ □ □

Full visibility at all times

For connected processes, the U-BTC can be integrated into the digital Memmert myChamber ecosystem. This brings digital functions for monitoring, device management and documentation into the testing process.

Available Models

7 model sizes

110 to 750


+20 to +120 °C

Setpoint range


2 variants

UN and UF


TwinDISPLAY

Standard on all models


Product data sheets

Download as Zip file

All models at a glance

UN110-BTC-HL4 108 Litre Dimensions Intérieures: 560 x 480 x 400 mm
UN110-BTC-HL4
UF110-BTC-HL4 108 Litre Dimensions Intérieures: 560 x 480 x 400 mm
UF110-BTC-HL4
UN160-BTC-HL4 161 Litre Dimensions Intérieures: 560 x 720 x 400 mm
UN160-BTC-HL4
UF160-BTC-HL4 161 Litre Dimensions Intérieures: 560 x 720 x 400 mm
UF160-BTC-HL4
UN250-BTC-HL4 256 Litre Dimensions Intérieures: 800 x 640 x 500 mm
UN250-BTC-HL4
UF250-BTC-HL4 256 Litre Dimensions Intérieures: 800 x 640 x 500 mm
UF250-BTC-HL4
UN260-BTC-HL4 256 Litre Dimensions Intérieures: 640 x 800 x 500 mm
UN260-BTC-HL4
UF260-BTC-HL4 256 Litre Dimensions Intérieures: 640 x 800 x 500 mm
UF260-BTC-HL4
UN400- BTC-HL4 384 Litre Dimensions Intérieures: 640 x 1200 x 500 mm
UN400- BTC-HL4
UF400- BTC-HL4 384 Litre Dimensions Intérieures: 640 x 1200 x 500 mm
UF400- BTC-HL4
UN450-BTC-HL4 449 Litre Dimensions Intérieures: 1040 x 720 x 600 mm
UN450-BTC-HL4
UF450- BTC-HL4 449 Litre Dimensions Intérieures: 1040 x 720 x 600 mm
UF450- BTC-HL4
UN750-BTC-HL4 749 Litre Dimensions Intérieures: 1040 x 1200 x 600 mm
UN750-BTC-HL4
UF750-BTC-HL4 749 Litre Dimensions Intérieures: 1040 x 1200 x 600 mm
UF750-BTC-HL4

Is the U-BTC right for your application?

Which model size and variant is suitable for your application depends, among other things, on the battery under test, temperature requirements and safety scope. Send us your requirements - we will support you in selecting the right U-BTC configuration.

Always ahead for you.

2026 – A year full of innovations.