More Space for Long Packaging Samples

For climate testing of long packaging samples made of cardboard and plastic, a customer in the Czech Republic required a climate chamber with specific interior design requirements. The HPP2200eco offered the necessary capacity, but its standard configuration with three separate compartments was unsuitable for the application. As part of its m360 customisation service, Memmert therefore developed a customised solution featuring two doors, an uninterrupted interior and specially designed support rails.

 

When the Size of the Test Samples Determines the Design

Cardboard and plastic packaging is exposed to different climatic conditions throughout its service life, which can affect the properties of the materials. To investigate how packaging responds to changes in temperature and humidity, samples are tested under defined climatic conditions.

For a customer in the Czech Republic, the main challenge was the size of the test samples. The customer needed a climate chamber that could accommodate particularly long packaging samples while allowing them to be loaded easily from the front. Conventional interior partitions would have restricted loading, as the entire available width of the chamber was needed for testing.

With these requirements, Czech Memmert sales partner Verkon approached our m360 department. The HPP2200eco was selected as the basis for the customised solution, offering an interior volume of 2,140 litres and sufficient space for large test samples. Its energy-efficient Peltier technology also enables precise control of temperature and relative humidity, as required for the planned climate tests.

Two Doors and an Uninterrupted Interior

In its standard configuration, the HPP2200eco features three doors and three separate interior compartments, divided by structural supports, partition panels and braces. However, this design was unsuitable for the intended application, as the long packaging samples needed to be accommodated without the restrictions imposed by individual compartments.

Our m360 experts therefore redesigned the door configuration and interior layout. Instead of the usual three doors, the climate chamber was equipped with two large stainless steel doors without viewing windows, while the existing partitions between the individual compartments were removed.

These modifications provide the customer with an uninterrupted interior space, allowing long and bulky packaging samples to be positioned across the full width of the chamber. At the same time, the two large doors improve accessibility, making it easier to load the samples from the front and remove them once testing is complete.

Specially Designed Longitudinal Support Rails

In addition to the modified door configuration and open interior, the positioning of the packaging samples also had to be considered. As the samples needed to be arranged in an organised manner and placed on suitable supports during climate testing, further structural modifications were required.

To achieve this, specially designed longitudinal support rails were integrated into the climate chamber. These rails provide support surfaces for the packaging samples and are tailored to the intended loading requirements. The samples can now be positioned directly on the rails from the front, without having to accommodate the partitions found in the standard configuration.

The combination of an uninterrupted interior and a customised support structure makes effective use of the available space and simplifies the handling of long packaging samples.

Climate Testing Under Different Temperature and Humidity Conditions

The customised HPP2200eco is used to investigate the behaviour of cardboard and plastic packaging under different temperature and humidity conditions. The test samples can be exposed to defined climatic conditions to assess how well they withstand the respective environmental influences.

The chamber continues to rely on the HPPeco's Advanced Peltier Technology, which, together with active humidification and dehumidification, enables precise control of the required climatic conditions. The distinguishing feature of this customised solution is therefore not an extension of the chamber's climate control capabilities, but its adaptation to the dimensions of the packaging samples and the way they are handled.

Customised Solutions with Memmert m360

The development of the HPP2200eco for the Czech customer was driven by the specific requirements of the testing process. Rather than adapting the packaging samples to the existing interior layout, the climate chamber itself was modified to make it easier to load the long samples and position them on specially designed support rails.

Working together with our sales partner Verkon, we developed a customised version that combines the proven climate control technology of the HPPeco with an interior tailored to the customer's application.

These types of modifications are part of the Memmert m360 service portfolio. Whether an application requires special dimensions, modifications to the interior layout or dedicated fixtures for holding test samples, our experts work closely with customers and sales partners to develop solutions tailored to their specific requirements.

 

Do you have an application for which a standard chamber is not the right fit?
Contact us to discuss your requirements.

Always ahead for you.

2026 – A year full of innovations.