Especificación técnica

Environmental test chamber CT1000EP75

Precise environmental simulation. Reliable results.
TESTA CT and TESTA TT environmental test chambers expand the Memmert portfolio with solutions for precise environmental simulation.
These chambers ensure reliable and reproducible testing conditions.

Download Product Sheets (ZIP)

On this page, you can find all the essential technical data on the Environmental test chambers TESTA CT / TT. Our customer relations team will be pleased to help if you want further information. If you should require a customised special solution, please contact our technical specialists at [email protected].

Range of functions

Adjustable parameters Temperature; Relative humidity
Adjustable device functions Climate control regulation; Real-time display of process variables; Program execution; Alarm definition and much more
Control unit Touch screen controller
Interfaces Ethernet LAN

Temperature

Setting temperature range -75 to +180 °C
Cooling system Water-cooled condensers are also available as standard in -75ºC models or an option for models with temperature cooling rate upgrades.
Temperature control system By stainless steel electric heaters located in the air treatment tunnel
Temperature fluctuations with time ± 0,1 to ± 0,3 K
Resolución del indicador valores nominales de la temperatura y valores reales 0,1 °C

Humidity

Setting range humidity 10 to 98 %rh
Humidification system Humidity: Through thermostatic bath with dew point control. Drying: Through thermostatic bath with dew point control and additional dry coil
Accuracy 0,1 % rh

Interior de acero inoxidable

Medidas An(A) x Al(B) x F(C): 984 x 910 x 1052 mm (F menos los 35 mm del ventilad)
Volumen 967 l
N° máx. de inserciones 10
Máx. carga de la cámara del equipo: 200 kg
Carga máx. por inserción 50 kg

Carcasa de acero estructural

Medidas An(D) x Al(E) x F(F): 1359 x 2010 x 1845 mm (F +56mm manilla de la puerta)
Instalación Ruedas para desplazamientos con posibilidad de bloqueo, nivelable

Datos eléctricos

Potencia 400 V, 3ph. w/o N 16A, 50 Hz / aprox. 22 W

Condiciones ambientales

Ambient conditions Distance to neighbouring appliances / wall clearances: 1000 mm back; 500 mm lateral

Datos de embalaje/envío

Country of origin Portugal
Información de transporte ¡Los equipos deben transportarse en posición vertical!
Número estadístico de mercancía 8419 8998
Medidas aprox. incl. cartón An x Al x F 1590 x 2190 x 2090 mm
Peso neto aprox. 910 kg
Peso bruto cartón aprox. 950 kg

Safety

Temperature monitoring Safety thermostat with High / Low temperature configuration, with automatic stop of all thermic systems
Temperature monitoring 1 Pt100 sensor DIN class A; 1 Pt100 sensor DIN class A, movable sensors for flexible placing inside chamber; Psychrometric humidity sensor | EP
Alarm Automatic stop function in case of water failure, with indication on the controller: High / Low humidity alarms; High / Low Temperature alarms

Standard equipment

Standard option Entryport Ø 80 mm, left; Water-cooled condenser (standard on models -75 and -40); Door locking, mechanical
Door Lockable door, double silicone door gaskets and anti-condensation heating frames
Additional accessories Water conductivity measuring device; Documentation package
Inserciones 2 bandeja(s) perforada(s) de acero inoxidable

Las unidades estándar están aprobadas en materia de seguridad y llevan las marcas certificadoras