Spécifications techniques

Freezer ULT750eco

Maximum protection for samples that matter.
Secure ultra-low temperature storage with high thermal stability, integrated safety mechanisms and energy-optimised cooling technology.

Download Product Sheets (ZIP)

On this page, you can find all the essential technical data on the ULT Freezer. Our customer relations team will be pleased to help if you want further information. If you should require a customised special solution, please contact our technical specialists at [email protected].

Range of functions

Adjustable parameters Temperature
Control unit 7” touchscreen integrated in the outer door in ergonomic position

Temperature

Setting temperature range -50 to -86 °C
Cooling system Cooling system with two (2) cascade-connected inverter compressors for precise temperature control and high energy efficiency. Refrigerants: First stage R290 / Second stage R170. Air-cooled condenser.
Résolution d'affichage des valeurs de la température de consigne et de la température réelle 0,1 °C

Safety

Power failure Backup battery for alarming and monitoring during power failure
Temperature monitoring Temperature sensor Pt1000
Alarme Visuelle et sonore

Communication

Interface Ethernet LAN,
USB

Standard equipment

Standard option Door-open detection;
Entry port / pressure relief opening Ø 26 mm, lateral,
Battery-backed alarm system
Door Insulated stainless steel outer doors with mechanical door lock
Additional accessories Standard interior configuration with 4 compartments. Consisting of 2 stainless steel inner doors and 3 height-adjustable shelves for flexible adaptation to different load sizes.

Caisson intérieur en acier inoxydable

Medidas w(A) x h(B) x d(C): 890 x 1345 x 627 mm
Max. number of 2" / 50mm boxes 576
Volume 750 l
Charge maximale de l'appareil: 400 kg
Charge max. par clayette 200 kg

Caisson extérieur en acier inox structuré

Mésures w(D) x h(E) x d(F): 1140 x 2000 x 888 mm
Installation Sur roulettes à frein intégré

Données sur l'emballage/l'expédition

Pays d'origine Netherlands
Information du transport Les appareils doivent être transportés en position verticale!
Dimensions env., carton inclus Dimensions avec l'emballage (L x H x P): 1410 x 2220 x 1080 mm
Poids net approximatif: 380 kg
Poids brut sous carton approximatif: 550 kg

Les unités standards ont reçu l’approbation de sécurité et contiennent les données de test

CE

Permettez-nous de vous aider à trouver votre Memmert

Envoyer la demande

Always ahead for you.

2026 – A year full of innovations.