Spécifications techniques

Environmental test chamber CT1000ECP40-10K

Precise environmental simulation. Reliable results.
TESTA CT and TESTA TT environmental test chambers expand the Memmert portfolio with solutions for precise environmental simulation.
These chambers ensure reliable and reproducible testing conditions.

Download Product Sheets (ZIP)

On this page, you can find all the essential technical data on the Environmental test chambers TESTA CT / TT. Our customer relations team will be pleased to help if you want further information. If you should require a customised special solution, please contact our technical specialists at [email protected].

Range of functions

Adjustable parameters Temperature; Relative humidity
Adjustable device functions Climate control regulation; Real-time display of process variables; Program execution; Alarm definition and much more
Control unit Touch screen controller
Interfaces Ethernet LAN

Temperature

Setting temperature range -75 to +180 °C
Cooling system Water-cooled condensers are also available as standard in -75ºC models or an option for models with temperature cooling rate upgrades.
Temperature control system By stainless steel electric heaters located in the air treatment tunnel
Temperature fluctuations with time ± 0,1 to ± 0,3 K
Résolution d'affichage des valeurs de la température de consigne et de la température réelle 0,1 °C

Humidity

Setting range humidity 10 to 98 %rh
Humidification system Humidity: Through thermostatic bath with dew point control. Drying: Through thermostatic bath with dew point control and additional dry coil
Accuracy 0,1 % rh

Safety

Temperature monitoring Safety thermostat with High / Low temperature configuration, with automatic stop of all thermic systems
Temperature monitoring 1 Pt100 sensor DIN class A; 1 Pt100 sensor DIN class A, movable sensors for flexible placing inside chamber; Capacitive and psychrometric humidity sensor | ECP
Alarm Automatic stop function in case of water failure, with indication on the controller: High / Low humidity alarms; High / Low Temperature alarms

Standard equipment

Standard option Entryport Ø 80 mm, left; Water-cooled condenser (standard on models -75 and -40); Door locking, mechanical
Door Lockable door, double silicone door gaskets and anti-condensation heating frames
Additional accessories Water conductivity measuring device; Documentation package
Clayettes 2 plateau(x) perforé(s) inox

Caisson intérieur en acier inoxydable

Mésures L(A) x H(B) x P(C): 984 x 910 x 1052 mm (P moins 35mm pour ventilateur)
Volume 967 l
Nombre max. clayettes 10
Charge maximale de l'appareil: 200 kg
Charge max. par clayette 50 kg

Caisson extérieur en acier inox structuré

Mésures L(D) x H(E) x P(F): 1359 x 2010 x 1845 mm (P +56mm hors poignée)
Installation Sur roulettes à frein intégré, support de mise à niveau

Données électriques

Puissance 400 V, 3ph. w/o N 16A, 50 Hz / environ 44 W

Conditions d'environnement

Ambient conditions Distance to neighbouring appliances / wall clearances: 1000 mm back; 500 mm lateral

Données sur l'emballage/l'expédition

Country of origin Portugal
Information du transport Les appareils doivent être transportés en position verticale!
Tarif douanier commun 8419 8998
Dimensions env., carton inclus Dimensions avec l'emballage (L x H x P): 1590 x 2190 x 2090 mm
Poids net approximatif: 910 kg
Poids brut sous carton approximatif: 950 kg

Les unités standards ont reçu l’approbation de sécurité et contiennent les données de test