On this page, you can find all the essential technical data on the U-BTC Battery test chamber. Our customer relations team will be pleased to help if you want further information. If you should require a customised special solution, please contact our technical specialists at [email protected].
Range of functions
| Adjustable device functions | Flap position Fan speed Time zones Alarm definition Real-time display of process variables Network settings (IP, subnet, DHCP) Timer Function and much more |
|---|---|
| Adjustable parameters | Temperature |
Temperature
| Setting accuracy | up to 99.9: 0.1 / from 100: 0.5 °C |
|---|---|
| Setting temperature range | +20 to +120 °C |
| Working temperature range | at least 10 above room temperature up to +120 °C |
| Temperature sensor | 2 Pt100 sensors DIN Class A in 4-wire-circuit for mutual monitoring, taking over functions in case of an error |
Control technology
| Calibration | three freely selectable temperature values |
|---|---|
| Language setting | German, English, Spanish, French, Polish, Czech, Hungarian, Italian, Chinese |
| ControlCOCKPIT | TwinDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with 2 high-definition TFT-colour displays. |
| Timer | Digital backwards counter with target time setting, adjustable from 1 minute to 99 days |
| Function SetpointWAIT | the process time does not start until the set temperature is reached |
Ventilation
| Convection | natural convection |
|---|---|
| Fresh air | Admixture of pre-heated fresh air by electronically adjustable air flap |
| Vent | vent connection with restrictor flap, electronically adjustable |
Communication
| Programming | myChamber Control software on a USB stick for programming, managing and transferring programmes via Ethernet interface or USB port |
|---|---|
| Interface | Ethernet LAN, USB |
| Documentation | programme stored in case of power failure |
Safety
| Pressure relief | To relieve pressure, the test chamber is fitted with a 120 mm diameter entry port. If excess pressure builds up inside the chamber – for example, due to gas being released from a test battery – the flap opens and relieves the pressure in a controlled manner. It then closes automatically under spring tension. |
|---|---|
| Door protection | The door is locked mechanically by means of clamping fasteners. In addition, an electronic door lock can be programmed according to the process, so that the door can only be opened during authorised process phases. A door-open detection system notifies the control system when the door is open. |
| Autodiagnostic system | for fault analysis |
| Temperature control | mechanical temperature limiter TB, protection class 1 according to DIN 12880 to switch off the heating approx. 20°C above nominal temperature |
| Temperature control | overtemperature monitor TWW, protection class 3.1 or adjustable temperature limiter TWB, protection class 2, selectable on display |
| AutoSAFETY | additionally integrated over- and undertemperature monitor "ASF", automatically following the setpoint value at a preset tolerance range, alarm in case of over- or undertemperature, heating is switched off in case of overtemperature |
| Alarm | visual and acoustic |
Stainless steel interior
| Dimensions | w(A) x h(B) x d(C): 560 x 480 x 400 mm |
|---|---|
| Volume | 108 l |
| Max. number of internals | 5 |
| Max. loading of chamber | 175 kg |
| Max. loading per internal | 20 kg |
Standard equipment
| Works calibration certificate | +100 °C |
|---|---|
| Door | Fully insulated stainless steel door with a 2-point locking system (compression door lock) and additional tension locks to secure the door |
Textured stainless steel casing
| Dimensions | w(D) x h(E) x d(F): 745 x 864 x 583 mm |
|---|---|
| Installation | 4 adjustable appliance feet |
Electrical data
| Voltage Electrical load | 230 V, 50/60 Hz approx. 2800 W |
|---|---|
| Voltage Electrical load | 115 V, 50/60 Hz approx. 1800 W |
Limitations of use
| Permissible temperature range for temperature tests | +20 to +120 °C |
|---|---|
| Max. air flow through the pressure relief flap | 1200 l/min |
| Max. total gas volume of the test specimen | 33 l |
| Test specimen, number | 3 |
| Test specimen type | 18650 cell, 2.2 Ah |
| Actuation pressure of the pressure relief flaps | 5 mbar |
| Max. pressure surge load on the test chamber | 10 mbar |
Ambient conditions
| Air humidity | max. 80 per cent relative humidity, non-condensing |
|---|---|
| Ambient conditions | Distance to neighbouring appliances / wall clearances: 1000 mm back; 500 mm lateral |
| Altitude of installation | max. 2,000 m above sea level |
| Ambient temperature | +5 °C to +40 °C |
| Overvoltage category | II |
| Pollution degree | 2 |
Packing/shipping data
| Country of origin | Federal Republic of Germany |
|---|---|
| Dimensions approx incl. carton | l x w x h: 830 x 800 x 1070 mm |
| Transport information | The appliances must be transported upright |
| Customs tariff number | 8419 8998 |
| WEEE-Reg.-No. | DE 66812464 |
| Net weight | approx. 74 kg |
| Gross weight carton | approx. 97 kg |
Standard units are safety-approved and bear the test marks