On this page, you can find all the essential technical data on the m360 cooled vacuum oven VOcool. Our customer relations team will be pleased to help if you want further information. Please contact our technical specialists at m360@memmert.com.
| Working temperature range | from 5°C (at least 20 below ambient temperature) to +90°C |
|---|---|
| Setting accuracy temperature | up to 99.9 °C: 0.1 / from 100 °C: 0.5 |
| Temperature sensor | temperature measured through 4-wire Pt100 sensor individually for each thermoshelf |
| Setting temperature range | from +5°C up to +90°C |
| resolution of display for actual values | 0.1°C |
| resolution of display for setpoint values | 0,1°C |
| Vacuum range | 5 to 1100 mbar |
|---|---|
| Pressure control | Digital electronic pressure control for a speed-controlled vacuum pump. Tubing for vacuum, air and inert gas are made of material 1.4571 (ASTM 316 Ti). Programmable, digitally controlled inlet for air. |
| Permitted final vacuum | 0.01 mbar |
| Maximum leakage rate | 0.01 bar/h |
| Pump control | speed control, optimised rinsing procedures for the pump membranes as well as signal output for pump ON/OFF |
| Connection | Vacuum connection with small flange DN16, and gas inlet with fresh air supply |
| Calibrate | Three freely selectable temperature values and three freely selectable pressure values |
|---|---|
| adjustable parameters | temperature (Celsius or Fahrenheit), pressure (vacuum), programme time, time zones, summertime/wintertime |
| Language setting | German, English, Spanish, French, Polish, Czech, Hungarian, Italian, Chinese |
| ControlCOCKPIT | TwinDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with 2 high-definition TFT-colour displays. |
| Timer | Digital backwards counter with target time setting, adjustable from 1 minute to 99 days |
| Function SetpointWAIT | the process time does not start until the set temperature is reached |
| Documentation | programme stored in case of power failure |
|---|---|
| Programming | AtmoCONTROL software on a USB stick for programming, managing and transferring programmes via Ethernet interface or USB port |
| Temperature control | mechanical temperature limiter TB, protection class 1 according to DIN 12880 to switch off the heating approx. 10°C above nominal temperature |
|---|---|
| AutoSAFETY | additionally integrated over- and undertemperature protection "ASF", automatically following the setpoint value at a preset tolerance range, alarm in case of over- or undertemperature, heating is switched off in case of overtemperature, compressor in case of undertemperature |
| Autodiagnostic system | integral fault diagnostics for temperature control |
| Alarm | visual and acoustic |
| Heating Concept | Connection for a thermoshelf in the rear panel |
|---|---|
| VO cooling | Peltier cooling unit ensures a surface temperature distribution with a maximum deviation of ±1 K across the entire temperature range |
| Number of slide-in units | 1 |
|---|---|
| Works calibration certificate | for +10°C/20 mbar |
| Door | full-sight glass door, inside spring-loaded, 15 mm thick glazed panel in safety glass, outside with anti-splitter screen |
| Internals | Cooling- and heating-combination of aluminium, material 3.3547 (ASTM B209), with integrated cooling circuit as well as large-area heating including local temperature sensing (Pt100, 4-wire-circuit); individual overtemperature protection. Further data see stainless steel interior. |
| Material | Hermetically welded stainless steel interior of extremely corrosion-resistant stainless steel, material 1.4404 |
|---|---|
| Volume | 101 l |
| Dimensions | w(A) x h(B) x d(C): 545 x 465 x 400 mm |
| Max. number of internals | 1 |
| Max. loading of chamber | 60 kg |
| Max. loading per internal | 20 kg |
| Installation | 4 adjustable appliance feet |
|---|---|
| Dimensions | w(D) x h(E) x d(F): 710 x 767 x 550 mm (d +38mm door handle) |
| Voltage Electrical load | 230 V, 50/60 Hz approx. 750 W |
|---|
| Altitude of installation | max. 2,000 m above sea level |
|---|---|
| Ambient temperature | +5 °C to +40 °C |
| Set Up | The distance between the wall and the rear of the chamber must be at least 15 cm. The clearance from the ceiling must not be less than 20 cm and the side clearance from the wall must not be less than 8 cm. |
| Humidity rh | max. 80 %, non-condensing |
| Overvoltage category | II |
| Pollution degree | 2 |
| Transport information | The appliances must be transported upright |
|---|---|
| Customs tariff number | 8419 8998 |
| Country of origin | Federal Republic of Germany |
| WEEE-Reg.-No. | DE 66812464 |
| Dimensions approx incl. carton | w x h x d: 830 x 1050 x 800 mm |
| Net weight | approx. 130 kg |
| Gross weight carton | approx. 160 kg |