On this page, you can find all the essential technical data on the m360 pass-through oven UF TS. Our customer relations team will be pleased to help if you want further information. Please contact our technical specialists at m360@memmert.com.
| Working temperature range | at least 10 above ambient temperature to +250 °C |
|---|---|
| Setting accuracy temperature | up to 99.9 °C: 0.1 / from 100 °C: 0.5 |
| Setting temperature range | +20 to +250°C |
| Temperature sensor | 2 Pt100 sensors DIN Class A in 4-wire-circuit for mutual monitoring, taking over functions in case of an error |
| ControlCOCKPIT | TwinDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with 2 high-definition TFT-colour displays. |
|---|---|
| Language setting | German, English, Spanish, French, Polish, Czech, Hungarian, Italian, Chinese |
| Timer | Digital backwards counter with target time setting, adjustable from 1 minute to 99 days |
| Function HeatBALANCE | adapting the distribution of the heating performance of the upper and lower heating circuit from -50 % to +50 % |
| Function SetpointWAIT | the process time does not start until the set temperature is reached |
| Calibration | three freely selectable temperature values |
| Fan | forced air circulation by quite air turbine, adjustable in 10 % steps for each segment individually |
|---|---|
| Fresh air | Admixture of pre-heated fresh air by electronically adjustable air flap |
| Vent | vent connection with restrictor flap, electronically adjustable |
| Documentation | programme stored in case of power failure |
|---|---|
| Programming | AtmoCONTROL software on a USB stick for programming, managing and transferring programmes via Ethernet interface or USB port |
| Temperature control | independently working, digitally adjustable electronic micro-processor overtemperature monitor TWW, protection class 3.1 (max-value for overtemperature, min-value for undertemperature) |
|---|---|
| Temperature control | mechanical temperature limiter TB, protection class 1 according to DIN 12880 to switch off the heating approx. 20°C above nominal temperature |
| AutoSAFETY | additionally integrated over- and undertemperature protection "ASF", automatically following the setpoint value at a preset tolerance range, alarm in case of over- or undertemperature, heating is switched off in case of overtemperature |
| Autodiagnostic system | for fault analysis |
| Alarm | visual and acoustic |
| Works calibration certificate | Calibration at +160°C |
|---|---|
| Door | fully insulated stainless steel door with 2-point locking (compression door lock) |
| Internals | 2 stainless steel grid(s), electropolished |
| Volume | 1248 l |
|---|---|
| Dimensions | w(A) x h(B) x d(C): 1040 x 1200 x 1000 mm |
| Max. number of internals | 14 |
| Max. loading of chamber | 300 kg |
| Max. loading per internal | 60 kg |
| Installation | 4 adjustable appliance feet |
|---|---|
| Dimensions | w(D) x h(E) x d(F): 1224 x 1714 x 1181 mm (d +2x56mm door handle) |
| Voltage Electrical load | 400 V and 3x 230 V w/o neutral, 50/60 Hz approx. 7000 W |
|---|
| Altitude of installation | max. 2,000 m above sea level |
|---|---|
| Ambient temperature | +5 °C to +40 °C |
| Humidity rh | max. 80 %, non-condensing |
| Overvoltage category | II |
| Pollution degree | 2 |
| Transport information | The appliances must be transported upright |
|---|---|
| Customs tariff number | 8419 8998 |
| Country of origin | Federal Republic of Germany |
| WEEE-Reg.-No. | DE 66812464 |
| Dimensions approx incl. carton | w x h x d: 1336 x 1960 x 1430 mm |
| Net weight | approx. 372 kg |
| Gross weight carton | approx. 600 kg |