Options / Accessories / Services

for Compressor-cooled incubator ICP750

Options

Options Order No.
Voltage 115 V, 50/60 Hz X2
Chamber modification for the application of reinforced perforated stainless steel shelves or stainless steel grids (bearing rails mounted in the working chamber) – includes replacement of standard grids by reinforced grids K1
Interior socket (can only be ordered with limited temperature range - max. +60 °C), ampacity 230V/2, 2A/500W, can be switched off with the On/Off switch, cannot be switched individually, moisture tight IP68 (requires option A8 against surcharge) R3
Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position left centre/centre Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position left centre/centre F0
Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position left centre top Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position left centre top F1
Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position right centre top Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position right centre top F3
Entry port (silicone), 40 mm clear diameter, moisture tight, can be closed by silicone stopper, at the back (please state location) F7
4 – 20 mA current loop interface (-20 to +70°C corresponds to 4 – 20 mA), temperature controller actual value V3
4 – 20 mA current loop interface (-20 to +70°C corresponds to 4 – 20 mA), temperature of a Pt100 sensor positioned flexibly in chamber for external temperature monitoring (max. 3 TwinDISPLAY) V6
Fan speed monitoring with switching off the heating and with alarm in case of failure V4
Door with lock and key (safety lock) Door with lock and key (safety lock) B6
Potential-free contact for combination error message (e.g. supply failure, sensor fault, fuse) Potential-free contact for combination error message (e.g. supply failure, sensor fault, fuse) H6
Door-open-recognition (only for units with TwinDISPLAY) V5
MobileALERT, notification by SMS in case of any error or alarm of the device (Requires option H6) C3

Accessories

Accessories Order No.
Stainless steel grids, electropolished Stainless steel grids, electropolished E20182
Reinforced stainless steel grid, electropolished, max. loading 60 kg; from size 450 with guide bars and fixing screws (only in connection with option K1). Please consider max. loading of chamber B32190
Perforated stainless steel shelf B68518
Reinforced perforated stainless steel shelves, max. loading 60 kg, with guide bars and fixing screws and only in connection with option K1. Please consider max. loading of chamber B68521
Stainless steel slide-in drip tray, 15 mm rim (may affect the temperature distribution) - cannot be used in connection with option K1 B02075
Stainless steel slide-in drip tray, 15 mm rim, with guide bars and fixing screws (may affect the temperature distribution) - can be used only in connection with option K1 B32763
Max. loading per slide-in drip tray (kg) 8
Stainless steel bottom drip tray, 15 mm rim (may affect the temperature distribution) - cannot be used in connection with option K1 B04362
Stainless steel bottom drip tray, 15 mm rim (may affect the temperature distribution) - can be used only in connection with option K1 B34055
Max. loading per bottom drip tray (kg) 8
USB-Ethernet adapter E06192
Ethernet connection cable 5 m for computer interface E06189
USB User-ID stick (with User-ID licence): Oven-linked authorisation licence (User-ID-programme) on Memory-stick, prevents undesired manipulation by unauthorised third parties. When reordering please specify serial number (only for units with TwinDISPLAY) B33170
Basic licence for AtmoCONTROL FDA and myChamber Control FDA. Meets the requirements for the use of electronically stored records and electronic signatures as set out in 21 CFR Part 11 of the US Food and Drug Administration (FDA). A volume discount is granted for the purchase of multiple licences per order. 10% for a minimum of 5 licences / 20% for a minimum of 10 licences / 30% for 20 or more licences FDAQ1

Services

Services Order No.
Calibration at Memmert factory for a freely selectable temperature value D00109
Calibration at Memmert factory for three temperature values: 0, +37, +60 °C Calibration at Memmert factory for three temperature values: 0, +37, +60 °C D00130
DAkkS calibration for one free-selectable temperature value according to method C (DKD-R 5-7) E39696
Extension of DAkkS calibration at Memmert factory by an additional freely selectable temperature value according to method C (DKD-R 5-7) E39697
IQ document with device-specific works test data, OQ/PQ check list as support for validation by customer D00124
IQ/OQ document with device-specific works test data, including temperature distribution survey with 9 temperature measuring points (size 30) and 27 temperature measuring points (sizes 55 - 1060) at Memmert factory for a freely selectable temperature value according to DIN12880:2007-05 (PQ check list as support for validation by customer) D00127
Extension of IQ/OQ document at Memmert factory by an additional freely selectable temperature value D49121
Short training on the handling and use of the device on site (outside Germany price on request) S49128
Calibration on site for a freely selectable temperature value (travel costs are not included yet) S00205
Extension of calibration on site by an additional freely selectable temperature value S00215
DAkkS calibration on site for a freely selectable temperature value according to method C (DKD-R 5-7) (travel costs are not included yet) S00360
IQ/OQ qualification on site including temperature distribution survey with 27 temperature measuring points for a freely selectable temperature value according to DIN12880:2007-05 (travel costs are not included yet) DLQ100
OQ requalification on site including temperature distribution survey with 27 temperature measuring points for a freely selectable temperature value according to DIN12880:2007-05 (travel costs are not included yet) DLQ100R
Extension of IQ/OQ qualification or OQ requalification on site by an additional freely selectable temperature value DLQ100A
PQ qualification on site (travel costs are not included yet) DLQ200
Maintenance on site ICP/ ICPeco according to Memmert maintenance plan (available on request) (travel costs are not included yet) S00315
Maintenance contract on site ICP/ ICPeco according to Memmert maintenance plan (available on request), minimum duration 3 years (travel costs are not included yet) S00315J

Always ahead for you.

2026 – A year full of innovations.