Fine glass and stainless steel. The elegant display has characterised Memmert lab ovens for many years now. Since the newest generation of appliances, our products have become intelligent and interactive. Meet the Memmert ControlCOCKPIT!
All adjustable parameters such as temperature (either Celsius or Fahrenheit), relative humidity, fan speed or exhaust air flap position can be set up in three quick steps without getting lost in a complicated menu. During operation all status messages, the current status of heating, ventilation and air flap position as well as time and alarm signals are visible simultaneously.
For many years, structured stainless steel has been the unmistakable feature of Memmert ovens, incubators and climate chambers in the laboratory. Functional design in its most elegant form: scratch-resistant, hygienic, robust and durable.
Wherever Memmert ovens and heating baths are used, the superiority of high-quality stainless steel is immediately evident compared to coated sheet steel which can corrode very quickly when in constant use.
For the outer housing of all Memmert appliances, structured stainless steel is used (rear walls are made of galvanised steel sheets).
Stainless steel of class W-St. 1.4301 (ASTM 304) is used for:
Since aggressive substances are frequently used in the vacuum drying oven, the inner chamber and thermoshelves are made of stainless steel W-St. 1.4404 (ASTM 316L), and the tubing is made of stainless steel W-St. 1.4571 (ASTM 316i).
The surface roughness of conventional stainless steel can neither be felt with the fingers nor be seen with the bare eyes. However, in some circumstances they can provide a large surface for germs only a few micrometers in length. When working with biological materials, the interior of the CO2 incubator ICOmed can be additionally electropolished. At the same time, the corrosion resistance of the material is increased by this procedure.
We think that the programming of a lab oven should be possible from anywhere in the world without problems. For this reason, Memmert devices feature state-of-the-art communication interfaces.
An ethernet connection for reading out logs is standard for all new generation Memmert lab -ovens.
For appliances with TwinDISPLAY, the ethernet connection can be used for:
Appliances with TwinDISPLAY offer a USB port on the ControlCOCKPIT for:
The individual allocation of IP addresses is possible directly via ControlCOCKPIT.
All Memmert lab ovens feature an electronic temperature monitoring system, a mechanical temperature limiter acc. to DIN 12880 and an integrated auto-diagnostic system with optical and acoustic alarm as a standard.
The technical service of Memmert has a demanding list of tasks. Supply of spare parts, maintenance, repair and commissioning, IQ/OQ/PQ qualification, customer training and software instruction. It all comes together with global network of service partners that ensures all user queries of Memmert appliances are addressed and fulfilled.