Hot air sterilizer with forced air circulation (fan) TwinDISPLAY SF110plus 745 x 864 x 584 mm
Steriliser S

To ensure laboratory equipment and devices are sterilized

Sterilisation done without requiring disinfection of laboratory instruments and equipment. A hot air sterilisation device protects and saves lives in medicine.

Intuitive Operation

Touch, turn & go! Easy and intuitive operation with the unique Memmert ControlCOCKPIT and software AtmoCONTROL. more

Safety

Safety of users and chamber loads: electronic temperature monitoring system, mechanical temperature limiter as well as an integrated auto-diagnostic system. more

High-quality Stainless steel

Beautiful and functional. Memmert stainless steel is scratch resistant, hygienic, robust and ever-lasting. more

Service

Worldwide at your disposal: Supply of spare parts, maintenance, repair, commissioning, IQ/OQ/PQ qualification, trainings and software instruction. more

Unlimited communication

Memmert appliances are equipped with state of the art interfaces for programming and communication. more

To ensure laboratory equipment and devices are sterilized

Hot air Steriliser S

What is hot air sterilisation? Steriliser S makes use of dry sterilisation to ensure laboratory equipment and devices are sterilized. With this method, hot air, devoid of water vapor or moisture, makes sure the device is sterile without needing risk prone disinfection methods.

Each Memmert hot air steriliser S is classified as class IIb medical device. Memmert is bringing medical devices of class IIb into circulation according to MDD 93/42/EEC until 31.12.2028 according to the transitional provisions by the (EU) 2023/607.

  • Hot air sterilisation temperature range up to +250 °C
  • 8 model sizes (32 to 749 liters volume) to heat sterilize as needed
  • 2 model variants: SingleDISPLAY and TwinDISPLAY
  • Natural convection or forced air circulation N/F

Advantages of using hot air sterilisation in Steriliser S

  • Intuitive and user friendly operating menu
  • SetpointWAIT function ensures that the program is only continued when the setpoint hot air sterilisation temperature is reached
  • Optional process-controlled, electromagnetic door lock (models with TwinDISPLAY)
  • User-ID function prevents manipulation in hot air sterilisers like Steriliser S
  • Almost exclusive use of high-quality, corrosion-resistant and easily cleanable stainless steel for the working chamber and housing
  • Heating concept specifically adaptable for a precise and homogenous temperature control
  • A wide range of options for reading the data logging using interfaces, integrated data logger and Software AtmoCONTROL
  • 3 years guarantee worldwide

Importance of hot air sterilisation

  • Precisely maintaining the heat sterilisation time and the termination of even the most resistant microorganisms.
  • For the special application of depyrogenisation, the hot air Steriliser S is absolutely ideal as an example of hot air sterilisation.

All models at a glance

SF30 32 Liter Internal Dimensions: 400 x 320 x 250 mm
SF30
SF30plus 32 Liter Internal Dimensions: 400 x 320 x 250 mm
SF30plus
SN30 32 Liter Internal Dimensions: 400 x 320 x 250 mm
SN30
SN30plus 32 Liter Internal Dimensions: 400 x 320 x 250 mm
SN30plus
SF55 53 Liter Internal Dimensions: 400 x 400 x 330 mm
SF55
SF55plus 53 Liter Internal Dimensions: 400 x 400 x 330 mm
SF55plus
SN55 53 Liter Internal Dimensions: 400 x 400 x 330 mm
SN55
SN55plus 53 Liter Internal Dimensions: 400 x 400 x 330 mm
SN55plus
SF75 74 Liter Internal Dimensions: 400 x 560 x 330 mm
SF75
SF75plus 74 Liter Internal Dimensions: 400 x 560 x 330 mm
SF75plus
SN75 74 Liter Internal Dimensions: 400 x 560 x 330 mm
SN75
SN75plus 74 Liter Internal Dimensions: 400 x 560 x 330 mm
SN75plus
SF110 108 Liter Internal Dimensions: 560 x 480 x 400 mm
SF110
SF110plus 108 Liter Internal Dimensions: 560 x 480 x 400 mm
SF110plus
SN110plus 108 Liter Internal Dimensions: 560 x 480 x 400 mm
SN110plus
SN110 108 Liter Internal Dimensions: 560 x 480 x 400 mm
SN110
SF160 161 Liter Internal Dimensions: 560 x 720 x 400 mm
SF160
SF160plus 161 Liter Internal Dimensions: 560 x 720 x 400 mm
SF160plus
SN160plus 161 Liter Internal Dimensions: 560 x 720 x 400 mm
SN160plus
SN160 161 Liter Internal Dimensions: 560 x 720 x 400 mm
SN160
SN260plus 256 Liter Internal Dimensions: 640 x 800 x 500 mm
SN260plus
SF260 256 Liter Internal Dimensions: 640 x 800 x 500 mm
SF260
SF260plus 256 Liter Internal Dimensions: 640 x 800 x 500 mm
SF260plus
SN260 256 Liter Internal Dimensions: 640 x 800 x 500 mm
SN260
SN450plus 449 Liter Internal Dimensions: 1040 x 720 x 600 mm
SN450plus
SF450 449 Liter Internal Dimensions: 1040 x 720 x 600 mm
SF450
SF450plus 449 Liter Internal Dimensions: 1040 x 720 x 600 mm
SF450plus
SN450 449 Liter Internal Dimensions: 1040 x 720 x 600 mm
SN450
SN750plus 749 Liter Internal Dimensions: 1040 x 1200 x 600 mm
SN750plus
SF750 749 Liter Internal Dimensions: 1040 x 1200 x 600 mm
SF750
SF750plus 749 Liter Internal Dimensions: 1040 x 1200 x 600 mm
SF750plus
SN750 749 Liter Internal Dimensions: 1040 x 1200 x 600 mm
SN750

Intended use as medical device

Memmert is bringing medical devices of class I according to EU Directive (EU) 2017/745 into circulation.

Type Intended use as medical device Classification according to (EU) 2017/745
UNmplus, UFmplus The appliance may be used for heating fango, silicate and APS packs for physical therapy and keeping them warm. I
UNm, UFm, INm, IFm The appliance may be used for heating fango, silicate and APS packs for physical therapy and keeping them warm. I
INmplus, IFmplus Implus may be used for temperature control of rinsing and infusion solutions and contrast agents. I
IFbw The appliance is used to heat non-sterile cloths and covers. Any other use is improper and may cause damage or danger. I

Memmert is bringing medical devices of class IIa and IIb into circulation according to MDD 93/42/EEC until 31.12.2028 according to the transitional provisions (EU) 2023/607 by the (EU) 2017/745 article 120 (2).

Type Intended use as medical device Classification according to 93/42/EWG
SNplus, SFplus The product is intended for the sterilisation of medical devices with dry heat at atmospheric pressure. IIb
SN, SF The product is intended for the sterilisation of medical devices with dry heat at atmospheric pressure. IIb
ICOmed The CO₂ incubator ICOmed is used to generate and maintain constant ambient conditions for the in-vitro fertilisation (IVF) application field, especially for the incubation of oocytes, spermatozoa and zygotes in special culture dishes for IVF application as well as for gene expression and the biosynthesis of RNA and proteins. IIa

Download as PDF

 

Medical device consultant training

As part of our medical device consultant training, we qualify you in the consultation, use and instruction of our medical products, taking into account the currently applicable legal requirements with regard to the new Medical Devices Regulation (EU) 2017/745. We explain the requirements for dealers, the geographical scope as well as information on the reporting system and the tasks of a medical device consultant.

After successful participation, you will receive a certificate of qualification as a medical device consultant for Memmert medical devices.

Have we piqued your interest? Please contact us at [email protected] for more information.

Always ahead for you.

2026 – A year full of innovations.