Options / Accessories / Services

for CO2 incubator ICOmed ICO150med

Safety at all times: High-end functions for incubation of cell cultures, bacteria cultures or tissue cultures.

Options

Options Order No.
Voltage 115 V, 50/60 Hz (no extra cost) X2
Electropolished interior T2
Active microprocessor control for humidifying and dehumidifying (40 - 97 % rh), incl. digital indication and auto-diagnostic system ensures even more rapid reaching of set humidity and very short recovery times while avoiding condensate formation. Humidity supply with water (only for demineralised water with a conductivity of 5 to 10 μS/cm and a pH value between 5and 7; from an external tank) by a self-priming pump; integral bacteria block by generating hot steam, dehumidifying via sterile filter (combination of options K7 and F7 for ICO50med not possible) K7
Control of oxygen concentration by N2 inlet; adjustment range 1 % up to 20 % O2 ; setting accuracy 0.1 % (requires option K7). Incl. N2 connection set: hose with coupling and clamp T6
Capacitive humidity sensor for measuring and displaying the relative humidity K6
Entry port (silicone), 40 mm clear diameter, moisture tight, can be closed by silicone stopper, at the back, centre right; not available for ICO50 with active humidity control (option K7) or humidity display (option K6) F7
Heated inner door with partitioned glass doors; size105/150/240 has 2/3/4 partitioned glass doors K4

Accessories

Accessories Order No.
Perforated stainless steel shelf E37418
Water dish B38737
Central water supply with filter cartridges for connection to the domestic water supply, only in combination with option K7. Product information on demand ZWVR6
Central water supply, without filter cartridges for connection to the domestic water supply (only for demineralised water with a conductivity of 5 to 10 μS/cm and a pH value between 5 and 7) only in combination with option K7. Product information on demand ZWVR7
HEPA14-filter for chamber according to EN 1822, packed in sterile condition, incl. fixing unit B49800
3 HEPA14-filters (B49800) for chamber according to EN 1822, packed in sterile condition, incl. fixing unit B39698
USB-Ethernet adapter E06192
Ethernet connection cable 5 m for computer interface E06189
USB User-ID stick (with User-ID licence): Oven-linked authorisation licence (User-ID-programme) on Memory-stick, prevents undesired manipulation by unauthorised third parties. When reordering please specify serial number (only for units with TwinDISPLAY) B33170
Stacking set (consisting of stacking corners, one connecting plate for the rear, two wall brackets) for stacking of two units of same size B42114
Subframe (622 mm high) adjustable in height (sizes 150/240: should not be used for 2 stacked units) B33505
Subframe (130 mm high); sizes 150/240: only in combination with the corresponding stacking sets for stacked appliances. B33508
CO2 pressure reducing valve DIN 8546, incl. Gas cylinder monitor E02087
N2 pressure reducing valve to DIN EN ISO 2503, incl. gas cylinder monitor (requires option T6) E06162
External measuring instrument with additional measuring head for temperature and humidity measurement. Product information on demand B04714

Services

Services Order No.
Guarantee extension by 1 year GA3Q5
DAkkS calibration for one free-selectable temperature value according to method C (DKD-R 5-7) E39696
Extension of DAkkS calibration at Memmert factory by an additional freely selectable temperature value according to method C (DKD-R 5-7) E39697
DAkkS calibration at Memmert factory for a freely selectable temperature and humidity value according to method C (DKD-R 5-7) (requires option K7) E48847
Extension of DAkkS calibration at Memmert factory by an additional freely selectable temperature and humidity value according to method C (DKD-R 5-7) (requires option K7) E48848
IQ document with device-specific works test data, OQ/PQ check list as support for validation by customer D00124
IQ/OQ document with device-specific works test data, including temperature distribution survey with 27 temperature measuring points at Memmert factory for a freely selectable temperature value according to DIN12880:2007-05 (PQ check list as support for validation by customer) D00127
IQ/OQ document with device-specific works test data, including temperature distribution survey with 27 temperature measuring points and 1 humidity measuring point in centre of usable space at Memmert factory for a freely selectable temperature and humidity value according to DIN12880:2007-05 (PQ check list as support for validation by customer) D00136
IQ/OQ document with device-specific works test data, including temperature distribution survey with 27 temperature measuring points, 1 humidity measuring point and 1 CO2 measuring point in centre of usable space at Memmert factory for a freely selectable temperature, humidity and CO2 value according to DIN12880:2007-05 (PQ check list as support for validation by customer) (requires option K7) D38897
IQ/OQ document with device-specific works test data, including temperature distribution survey with 27 temperature measuring points and 1 CO2 measuring point in centre of usable space at Memmert factory for a freely selectable temperature and CO2 value according to DIN12880:2007-05 (PQ check list as support for validation by customer) D38898
Extension of IQ/OQ document at Memmert factory by an additional freely selectable temperature value D49121
Extension of IQ/OQ document at Memmert factory by an additional freely selectable temperature and humidity value (requires option K7) D49122
Extension of IQ/OQ document at Memmert factory by an additional freely selectable temperature, humidity and CO2 value (requires option K7) D49123
Extension of IQ/OQ document at Memmert factory by an additional freely selectable temperature and CO2 value D49124
Short training on the handling and use of the device on site (outside Germany price on request) S49128
Calibration on site for a freely selectable temperature value (travel costs are not included yet) S00205
Calibration on site for a freely selectable temperature and humidity value (requires option K7) (travel costs are not included yet) S00207
Calibration of one freely selectable temperature and humidity value including CO2 (excluding travel costs, not subject to discount, GER, AT, FR only) S00211
Extension of calibration on site by an additional freely selectable temperature value S00215
Extension of calibration on site by an additional freely selectable temperature and humidity value (requires option K7) S00216
Extension of calibration on site by an additional freely selectable temperature, humidity and CO2 value (requires option K7) S00217
DAkkS calibration on site for a freely selectable temperature value according to method C (DKD-R 5-7) (travel costs are not included yet) S00360
DAkkS calibration on site for a freely selectable temperature and humidity value according to method C (DKD-R 5-7) (requires option K7) (travel costs are not included yet) S00365
IQ/OQ qualification on site including temperature distribution survey with 27 temperature measuring points for a freely selectable temperature value according to DIN12880:2007-05 (travel costs are not included yet) DLQ100
IQ/OQ qualification on site including temperature distribution survey with 27 temperature measuring points and 1 humidity measuring point in centre of usable space for a freely selectable temperature and humidity value according to DIN12880:2007-05 (requires option K7) (travel costs are not included yet) DLQ101
IQ/OQ qualification on site including temperature distribution survey with 27 temperature measuring points and 1 CO2 measuring point in centre of usable space for a freely selectable temperature and CO2 value according to DIN12880:2007-05 (travel costs are not included yet) DLQ102
IQ/OQ qualification on site including temperature distribution survey with 27 temperature measuring points, 1 humidity measuring point and 1 CO2 measuring point in centre of usable space for a freely selectable temperature, humidity and CO2 value according to DIN12880:2007-05 (requires option K7) (travel costs are not included yet) DLQ103
IQ/OQ qualification on site including temperature distribution survey with 27 temperature measuring points, 1 CO2 measuring point and 1 O2 measuring point in centre of usable space for a freely selectable temperature, CO2 and O2 value according to DIN12880:2007-05 (requires option T6) (travel costs are not included yet) DLQ104
IQ/OQ qualification on site including temperature distribution survey with 27 temperature measuring points, 1 humidity measuring point, 1 CO2 measuring point and 1 O2 measuring point in centre of usable space for a freely selectable temperature, humidity, CO2 and O2 value according to DIN12880:2007-05 (requires option K7 and T6) (travel costs are not included yet) DLQ105
OQ requalification on site including temperature distribution survey with 27 temperature measuring points for a freely selectable temperature value according to DIN12880:2007-05 (travel costs are not included yet) DLQ100R
OQ requalification on site including temperature distribution survey with 27 temperature measuring points and 1 humidity measuring point in centre of usable space for a freely selectable temperature and humidity value according to DIN12880:2007- 05 (requires option K7) (travel costs are not included yet) DLQ101R
OQ requalification on site including temperature distribution survey with 27 temperature measuring points and 1 CO2 measuring point in centre of usable space for a freely selectable temperature and CO2 value according to DIN12880:2007-05 (travel costs are not included yet) DLQ102R
OQ requalification on site including temperature distribution survey with 27 temperature measuring points, 1 humidity measuring point and 1 CO2 measuring point in centre of usable space for a freely selectable temperature, humidity and CO2 value according to DIN12880:2007-05 (requires option K7) (travel costs are not included yet) DLQ103R
OQ requalification on site including temperature distribution survey with 27 temperature measuring points, 1 CO2 measuring point and 1 O2 measuring point in centre of usable space for a freely selectable temperature, CO2 and O2 value according to DIN12880:2007-05 (requires option T6) (travel costs are not included yet) DLQ104R
OQ requalification on site including temperature distribution survey with 27 temperature measuring points, 1 humidity measuring point, 1 CO2 measuring point and 1 O2 measuring point in centre of usable space for a freely selectable temperature, humidity, CO2 and O2 value according to DIN12880:2007-05 (requires option K7 and T6) (travel costs are not included yet) DLQ105R
Extension of IQ/OQ qualification or OQ requalification on site by an additional freely selectable temperature value DLQ100A
Extension of IQ/OQ qualification or OQ requalification on site by an additional freely selectable temperature and humidity value (requires option K7) DLQ101A
Extension of IQ/OQ qualification or OQ requalification on site by an additional freely selectable temperature and CO2 value DLQ102A
Extension of IQ/OQ qualification or OQ requalification on site by an additional freely selectable temperature, humidity and CO2 value (requires option K7) DLQ103A
Extension of IQ/OQ qualification or OQ requalification on site by an additional freely selectable temperature, CO2 and O2 value (requires option T6) DLQ104A
Extension of IQ/OQ qualification or OQ requalification on site by an additional freely selectable temperature, humidity, CO2 and O2 value (requires option K7 and T6) DLQ105A
PQ qualification on site (travel costs are not included yet) DLQ200
Maintenance on site ICO/ ICOmed active humidity according to Memmert maintenance plan (available on request) (requires option K7) (travel costs are not included yet) S00312
Maintenance on site ICO/ ICOmed passive humidity according to Memmert maintenance plan (available on request) (travel costs are not included yet) S00323
Maintenance contract on site ICO/ ICOmed active humidity according to Memmert maintenance plan (available on request), minimum duration 3 years (requires option K7) (travel costs are not included yet) S00312J
Maintenance contract on site ICO/ ICOmed passive humidity according to Memmert maintenance plan (available on request), minimum duration 3 years (travel costs are not included yet) S00323J

Always ahead for you.

2026 – A year full of innovations.