Interior socket (can only be ordered with limited temperature range - max. +60 °C), ampacity 230V/2, 2A/500W, can be switched off with the On/Off switch, cannot be switched individually, moisture tight IP68 (requires option A8 against surcharge)
R3
Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position left centre/centre
F0
Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position left centre top
F1
Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position right centre top
F3
Entry port (silicone), 40 mm clear diameter, moisture tight, can be closed by silicone stopper, at the back (please state location)
F7
4 – 20 mA current loop interface (-20 to +70°C corresponds to 4 – 20 mA), temperature controller actual value
V3
4 – 20 mA current loop interface (-20 to +70°C corresponds to 4 – 20 mA), temperature of a Pt100 sensor positioned flexibly in chamber for external temperature monitoring (max. 3 TwinDISPLAY)
V6
Fan speed monitoring with switching off the heating and with alarm in case of failure
Door-open-recognition (only for units with TwinDISPLAY)
V5
MobileALERT, notification by SMS in case of any error or alarm of the device (Requires option H6)
C3
Accessories
Accessories
Order No.
Stainless steel grids, electropolished
E28891
Reinforced stainless steel grid, electropolished, max. loading 60 kg; from size 450 with guide bars and fixing screws (only in connection with option K1). Please consider max. loading of chamber
E29766
Perforated stainless steel shelf
B68510
Stainless steel slide-in drip tray, 15 mm rim (may affect the temperature distribution) - cannot be used in connection with option K1
B29726
Max. loading per slide-in drip tray (kg)
4
Stainless steel bottom drip tray, 15 mm rim (may affect the temperature distribution) - cannot be used in connection with option K1
B29722
Max. loading per bottom drip tray (kg)
4
USB-Ethernet adapter
E06192
Ethernet connection cable 5 m for computer interface
E06189
USB User-ID stick (with User-ID licence): Oven-linked authorisation licence (User-ID-programme) on Memory-stick, prevents undesired manipulation by unauthorised third parties. When reordering please specify serial number (only for units with TwinDISPLAY)
B33170
Basic licence for AtmoCONTROL FDA and myChamber Control FDA. Meets the requirements for the use of electronically stored records and electronic signatures as set out in 21 CFR Part 11 of the US Food and Drug Administration (FDA). A volume discount is granted for the purchase of multiple licences per order. 10% for a minimum of 5 licences / 20% for a minimum of 10 licences / 30% for 20 or more licences
FDAQ1
Services
Services
Order No.
Calibration at Memmert factory for a freely selectable temperature value
D00109
Calibration at Memmert factory for three temperature values: 0, +37, +60 °C
D00130
DAkkS calibration for one free-selectable temperature value according to method C (DKD-R 5-7)
E39696
Extension of DAkkS calibration at Memmert factory by an additional freely selectable temperature value according to method C (DKD-R 5-7)
E39697
IQ document with device-specific works test data, OQ/PQ check list as support for validation by customer
D00124
IQ/OQ document with device-specific works test data, including temperature distribution survey with 9 temperature measuring points (size 30) and 27 temperature measuring points (sizes 55 - 1060) at Memmert factory for a freely selectable temperature value according to DIN12880:2007-05 (PQ check list as support for validation by customer)
D00127
Extension of IQ/OQ document at Memmert factory by an additional freely selectable temperature value
D49121
Short training on the handling and use of the device on site (outside Germany price on request)
S49128
Calibration on site for a freely selectable temperature value (travel costs are not included yet)
S00205
Extension of calibration on site by an additional freely selectable temperature value
S00215
DAkkS calibration on site for a freely selectable temperature value according to method C (DKD-R 5-7) (travel costs are not included yet)
S00360
IQ/OQ qualification on site including temperature distribution survey with 27 temperature measuring points for a freely selectable temperature value according to DIN12880:2007-05 (travel costs are not included yet)
DLQ100
OQ requalification on site including temperature distribution survey with 27 temperature measuring points for a freely selectable temperature value according to DIN12880:2007-05 (travel costs are not included yet)
DLQ100R
Extension of IQ/OQ qualification or OQ requalification on site by an additional freely selectable temperature value
DLQ100A
PQ qualification on site (travel costs are not included yet)
DLQ200
Maintenance on site ICP/ ICPeco according to Memmert maintenance plan (available on request) (travel costs are not included yet)
S00315
Maintenance contract on site ICP/ ICPeco according to Memmert maintenance plan (available on request), minimum duration 3 years (travel costs are not included yet)