Options / Accessories / Services

for Constant climate chamber

Maximum energy efficiency in continuous operation - tailor-made for stability studies according to ICH guidelines, stability tests for cosmetics and foods as well as environmental testing and material testing

Options

Model sizes 110 260 410 750 1060 1400 2200
The performance option increases the number of installed Peltier modules in size 260 and 410 from 1 to 2, and in size 750 from 2 to 4 units. This enhances performance and improves technical specifications. P1 P1 P1
Temperature restriction; Temperature: +60 °C A8 A8 A8 A8 A8
Chamber modification for the application of reinforced perforated stainless steel shelves or stainless steel grids (bearing rails mounted in the working chamber) - includes replacement of standard grids by reinforced grids (standard with 1060) K1
Cold white 6,500 K light module: LED light strips on the side walls, 10 for model 110, 14 for model 260/410/750, programme-controlled dimming from 0 to 100 % (in 1 % increments), ramp programming in conjunction with temperature and humidity. Requires option P1 for sizes 260, 410 and 750 at an extra charge. Standard feed-through not required for sizes 110 and 260. T7 T7 T7 T7
Light module cold white 6,500 K + warm white 2,700 K: LED light strips - 10 for model 110, 14 for model 260/410/750 - (alternating 5 or 7 light strips cold white and 5 or 7 light strips warm white) on the side walls, programme-controlled dimming from 0 to 100 % (in 1 % increments), ramp programming in conjunction with temperature and humidity. Requires option P1 for sizes 260, 410 and 750 at an extra charge. Standard feed-through not required for sizes 110 and 260. T8 T8 T8 T8
Light module warm white 2,700 K: LED light strips on the side walls, 10 for model 110, 14 for model 260/410/750, programme-controlled dimming from 0 - 100 % (in 1 % increments), ramp programming in conjunction with temperature and humidity. Requires option P1 for sizes 260, 410 and 750 at an extra charge. Standard feed-through not required for sizes 110 and 260. T9 T9 T9 T9
Interior socket (can only be ordered with limited temperature range - max. +60 °C), ampacity 230V/2, 2A/500W, can be switched off with the On/Off switch, cannot be switched individually, moisture tight IP68 (requires option A8 against surcharge) R3 R3 R3 R3 R3
Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position left centre/centre Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position left centre/centre F0 F0 F0 F0 F0
Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position left centre top Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position left centre top F1 F1 F1 F1 F1
Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position right centre/centre Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position right centre/centre F2 F2 F2 F2 F2
Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position right centre top Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position right centre top F3 F3 F3 F3 F3
Entry port, 23 mm clear diameter for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper (please, state location) - left Entry port, 23 mm clear diameter for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper (please, state location) - left F4 F4 F4 F4 F4 F4 F4
Entry port, 23 mm clear diameter for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper (please, state location) - right Entry port, 23 mm clear diameter for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper (please, state location) - right F5 F5 F5 F5 F5 F5 F5
Entry port, 23 mm clear diameter, moisture tight, can be closed by flap and silicone stopper, in special positions (please, state location) – rear Entry port, 23 mm clear diameter, moisture tight, can be closed by flap and silicone stopper, in special positions (please, state location) – rear F6 F6 F6 F6 F6
Entry port (silicone), 40 mm clear diameter, moisture tight, can be closed by silicone stopper, at the back (please state location) F7 F7 F7 F7 F7
Entry port (silicone), 40 mm clear diameter, moisture tight, can be closed by silicone stopper, standard position rear D8 D8 D8 D8 D8 D8 D8
4 – 20 mA current loop interface (-10 to +80°C corresponds to 4 to 20 mA), temperature controller, actual value V3 V3 V3 V3 V3 V3 V3
Compressed air drying (efficient dehumidification of the interior by compressed air supply) - Standard factory calibration certificate (measuring point centre of usable space) for +10 °C with 10 % rh. (requires option P1 for sizes 260, 410 and 750 at an extra charge) C9 C9 C9 C9 C9
Door with lock and key (safety lock) Door with lock and key (safety lock) B6 B6 B6 B6 B6
Door with lock and key (safety lock), two locks (one each door) B62
Door with lock and key (safety lock), three locks (one each door) B63
Potential-free contact for combination error message (e.g. supply failure, sensor fault, fuse) Potential-free contact for combination error message (e.g. supply failure, sensor fault, fuse) H6 H6 H6 H6 H6 H6 H6
Process-dependent programmable door lock (only for units with TwinDISPLAY) D4 D4 D4 D4 D4
Process-dependent programmable door lock, two interlocking systems (one each other) D42
Process-dependent programmable door lock, three interlocking systems (one each other) D43
Door-open-recognition (only for units with TwinDISPLAY) V5 V5 V5 V5 V5
Door-open-recognition, two (one each door) V52
Door-open-recognition, three (one each door) V53
MobileALERT, notification by SMS in case of any error or alarm of the device (Requires option H6) C3 C3 C3 C3 C3 C3 C3
MobileALERT for 2 alarm notifications; notification by SMS. temperature and humidity alarm (requires option H6) C4 C4 C4 C4 C4 C4 C4
Castor frame (2-part), height 140 mm Castor frame (2-part), height 140 mm R9 R9

Accessories

Model sizes 110 260 410 750 1060 1400 2200
Reinforced stainless steel shelf, max. loading 60 kg; with guide bars and fixing screws (requires option K1). Please consider max. loading of chamber B68521 B68523
Stainless steel perforated sheet (may affect the temperature distribution). With option P1, the performance is increased for sizes 260, 410, and 750. Option P1 is required for appliance size 410. B68508 B68510 B68510 B68518
Stainless steel grids, electropolished Stainless steel grids, electropolished E20165 E28891 E28891 E20182 B41251 B38955 B38955
Reinforced stainless steel grid, electropolished, max. loading 60 kg (model 750 with guide bars and fixing screws and only in connection with option K1) Please consider max. loading of chamber E29767 E29766 E29766 B32190 B32550
Stainless steel slide-in drip tray, 15 mm rim (may affect the temperature distribution) - cannot be used in connection with option K1 B02073 B29726 B29726 B02075 B32599
Stainless steel slide-in drip tray, 15 mm rim, with guide bars and fixing screws (may affect the temperature distribution) - can be used only in connection with option K1 B32763
Stainless steel bottom drip tray, 15 mm rim (may affect the temperature distribution) - cannot be used in connection with option K1 B04359 B29722 B29722 B04362 B29769
Stainless steel bottom drip tray, 15 mm rim (may affect the temperature distribution) - can be used only in connection with option K1 B34055
Holder for water tank (sizes 110 - 750: 2.5 litres, sizes 1060/1400/2200: 10 litres) for mounting on the rear of the appliance. Standard equipment for sizes 410, 750, 1060, 1400 and 2200. B49092 B49092
Central water supply with filter cartridges for connection to the domestic water supply. Product information on demand. ZWVR6 ZWVR6 ZWVR6 ZWVR6 ZWVR6 ZWVR6 ZWVR6
Central water supply without filter cartridges for connection to the domestic water supply (only for demineralised water with a conductivity of 5 to 10 μS/cm and a pH value between 5 and 7). Product information on demand ZWVR7 ZWVR7 ZWVR7 ZWVR7 ZWVR7 ZWVR7 ZWVR7
Max. loading per slide-in drip tray (kg) 3 4 4 8 8
Max. loading per bottom drip tray (kg) 3 4 4 8 8
USB-Ethernet adapter E06192 E06192 E06192 E06192 E06192 E06192 E06192
Ethernet connection cable 5 m for computer interface E06189 E06189 E06189 E06189 E06189 E06189 E06189
USB User-ID stick (with User-ID licence): Oven-linked authorisation licence (User-ID-programme) on Memory-stick, prevents undesired manipulation by unauthorised third parties. When reordering please specify serial number (only for units with TwinDISPLAY) B33170 B33170 B33170 B33170 B33170 B33170 B33170
Set of height adjustable feet (4 pcs) B29768 B29768
Stacking set (4 pcs) for stacking of appliances of same size Stacking set (4 pcs) for stacking of appliances of same size B29744
Flush-fit unit (stainless steel frame covering gap between oven and wall opening), with air slots – technical clarification required Flush-fit unit (stainless steel frame covering gap between oven and wall opening), with air slots – technical clarification required B29734 B29738 B42116 B29742 B29742
Flush-fit unit (stainless steel frame covering gap between oven and wall opening), without air slots – technical clarification required Flush-fit unit (stainless steel frame covering gap between oven and wall opening), without air slots – technical clarification required B29735 B29739 B41227 B29743 B29743
Subframe, adjustable in height (size 30 to 75: height 600 mm, size 110 to 450: height 500 mm) Subframe, adjustable in height (size 30 to 75: height 600 mm, size 110 to 450: height 500 mm) B29749 B29751
Subframe, on castors (size 30 to 75: height 660 mm, size 110 to 160: height 560 mm) Subframe, on castors (size 30 to 75: height 660 mm, size 110 to 160: height 560 mm) B29750
Subframe, adjustable in height, height 130 mm B33661 B33664
Basic licence for AtmoCONTROL FDA and myChamber Control FDA. Meets the requirements for the use of electronically stored records and electronic signatures as set out in 21 CFR Part 11 of the US Food and Drug Administration (FDA). A volume discount is granted for the purchase of multiple licences per order. 10% for a minimum of 5 licences / 20% for a minimum of 10 licences / 30% for 20 or more licences FDAQ1 FDAQ1 FDAQ1 FDAQ1 FDAQ1 FDAQ1 FDAQ1
External measuring instrument with sensors for daylight and UV-light. Product information on demand (models HPPeco, ICHLeco/ ICHL, IPPecoplus) B04713 B04713 B04713 B04713
External measuring instrument with sensors with additional measuring head for temperature and humidity measurement. Product information on demand (models HPPeco, ICHeco/ICH, ICHLeco/ICHL, IPPecoplus and ICOmed) B04714 B04714 B04714 B04714 B04714 B04714 B04714

Services

Model sizes 110 260 410 750 1060 1400 2200
Guarantee extension by 1 year GA2Q5 GA3Q5 GA3Q5 GA3Q5 GA4Q5 GA4Q5 GA4Q5
Calibration at Memmert factory for a freely selectable temperature and humidity value D00105 D00105 D00105 D00105 D00105 D00105 D00105
Calibration at Memmert factory for a freely selectable temperature value D00109 D00109 D00109 D00109 D00109 D00109 D00109
DAkkS calibration for one free-selectable temperature value according to method C (DKD-R 5-7) E39696 E39696 E39696 E39696 E39696 E39696 E39696
Extension of DAkkS calibration at Memmert factory by an additional freely selectable temperature value according to method C (DKD-R 5-7) E39697 E39697 E39697 E39697 E39697 E39697 E39697
DAkkS calibration at Memmert factory for a freely selectable temperature and humidity value according to method C (DKD-R 5-7) E48847 E48847 E48847 E48847 E48847 E48847 E48847
Extension of DAkkS calibration at Memmert factory by an additional freely selectable temperature and humidity value according to method C (DKD-R 5-7) E48848 E48848 E48848 E48848 E48848 E48848 E48848
IQ document with device-specific works test data, OQ/PQ check list as support for validation by customer D00124 D00124 D00124 D00124 D00124 D00124 D00124
IQ/OQ document with device-specific works test data, including temperature distribution survey with 27 temperature measuring points (sizes 110 - 1060, 2200) and 26 temperature measuring points (size 1400) at Memmert factory for a freely selectable temperature value according to DIN12880:2007-05 (PQ check list as support for validation by customer) D00127 D00127 D00127 D00127 D00127 D00127 D00127
IQ/OQ document with device-specific works test data, including temperature distribution survey with 27 temperature measuring points (sizes 110 - 1060, 2200), 26 temperature measuring points (size 1400) and 1 humidity measuring point in centre of usable space at Memmert factory for a freely selectable temperature and humidity value according to DIN12880:2007-05 (PQ check list as support for validation by customer) D00136 D00136 D00136 D00136 D00136 D00136 D00136
IQ/OQ document with device-specific works test data for one free-selectable temperature and humidity value, and measuring of light intensity, incl. temperature distribution survey at Memmert for 27 measuring points to DIN 12880:2007-05, PQ check list as support for validation by customer. Price for validation at customer site on demand (GER, AT, CH only) D00137 D00137 D00137 D00137
Extension of IQ/OQ document at Memmert factory by an additional freely selectable temperature value D49121 D49121 D49121 D49121 D49121 D49121 D49121
Extension of IQ/OQ document at Memmert factory by an additional freely selectable temperature and humidity value D49122 D49122 D49122 D49122 D49122 D49122 D49122
Extension of IQ/OQ document at Memmert factory by an additional freely selectable temperature, humidity and light intensity value D49125 D49125 D49125 D49125
Short training on the handling and use of the device on site (outside Germany price on request) S49128 S49128 S49128 S49128 S49128 S49128 S49128
Calibration on site for a freely selectable temperature value (travel costs are not included yet) S00205 S00205 S00205 S00205 S00205 S00205 S00205
Calibration on site for a freely selectable temperature and humidity value (travel costs are not included yet) S00207 S00207 S00207 S00207 S00207 S00207 S00207
Extension of calibration on site by an additional freely selectable temperature value S00215 S00215 S00215 S00215 S00215 S00215 S00215
Extension of calibration on site by an additional freely selectable temperature and humidity value S00216 S00216 S00216 S00216 S00216 S00216 S00216
DAkkS calibration on site for a freely selectable temperature value according to method C (DKD-R 5-7) (travel costs are not included yet) S00360 S00360 S00360 S00360 S00360 S00360 S00360
DAkkS calibration on site for a freely selectable temperature and humidity value according to method C (DKD-R 5-7) (travel costs are not included yet) S00365 S00365 S00365 S00365 S00365 S00365 S00365
IQ/OQ qualification on site including temperature distribution survey with 9 temperature measuring points (size 30), 27 temperature measuring points (sizes 55 - 1060, 2200) and 28 temperature measuring points (size 1400) for a freely selectable temperature value according to DIN12880:2007-05 (travel costs are not included yet) DLQ100 DLQ100 DLQ100 DLQ100 DLQ100 DLQ100 DLQ100
IQ/OQ qualification on site including temperature distribution survey with 27 temperature measuring points (sizes 110 - 1060, 2200), 26 temperature measuring points (size 1400) and 1 humidity measuring point in centre of usable space for a freely selectable temperature and humidity value according to DIN12880:2007-05 (travel costs are not included yet) DLQ101 DLQ101 DLQ101 DLQ101 DLQ101 DLQ101 DLQ101
OQ requalification on site including temperature distribution survey with 9 temperature measuring points (size 30), 27 temperature measuring points (sizes 55 - 1060, 2200) and 28 temperature measuring points (size 1400) for a freely selectable temperature value according to DIN12880:2007-05 (travel costs are not included yet) DLQ100R DLQ100R DLQ100R DLQ100R DLQ100R DLQ100R DLQ100R
OQ requalification on site including temperature distribution survey with 27 temperature measuring points (sizes 110 - 1060, 2200), 26 temperature measuring points (size 1400) and 1 humidity measuring point in centre of usable space for a freely selectable temperature and humidity value according to DIN12880:2007-05 (travel costs are not included yet) DLQ101R DLQ101R DLQ101R DLQ101R DLQ101R DLQ101R DLQ101R
Extension of IQ/OQ qualification or OQ requalification on site by an additional freely selectable temperature value DLQ100A DLQ100A DLQ100A DLQ100A DLQ100A DLQ100A DLQ100A
Extension of IQ/OQ qualification or OQ requalification on site by an additional freely selectable temperature and humidity value DLQ101A DLQ101A DLQ101A DLQ101A DLQ101A DLQ101A DLQ101A
PQ qualification on site (travel costs are not included yet) DLQ200 DLQ200 DLQ200 DLQ200 DLQ200 DLQ200 DLQ200
Maintenance on site HPPeco according to Memmert maintenance plan (available on request) (travel costs are not included yet) S00314 S00314 S00314 S00314 S00314 S00314 S00314
Maintenance contract on site HPPeco according to Memmert maintenance plan (available on request), minimum duration 3 years (travel costs are not included yet) S00314J S00314J S00314J S00314J S00314J S00314J S00314J