Options / Accessories / Services

for HPP410

Options

Options Order No.
Voltage 115 V, 50/60 Hz (no extra cost) X2
Light module cold white 6,500 K: LED light strips arranged on the side walls of the interior,10 for model 110, 14 for model 260/410/750,programme controlled dimming from 0 to 100% (in 1 % steps), ramp programming in combination with temperature and humidity (not in combination with F6, F7, D8) T7
Light module cold white 6,500K + warm white 2,700K: LED light strips - 10 stripes for model 110, 14 for model 260/410/750 (6 resp. 8 alternating coldwhite light strips and 4 resp. 6 warm white light strips) on the side walls of the interior, programme-controlled dimming from 0 to100% (in 1 % steps), ramp programming in combination with temperature and humidity (not in combination with F6, F7, D8) T8
Light module warm white 2,700 K: light strips arranged on the side walls of the interior, 10 strips for model 110, 14 for model 260/400/750, programme-controlled dimming rom 0 to100% (in 1 % steps), ramp programming in combination with temperature and humidity (not in combination with F6, F7, D8) T9
Interior socket (can only be ordered with limited temperature range - max. +60 °C), ampacity 230V/2, 2A/500W, can be switched off with the On/Off switch, cannot be switched individually, moisture tight IP68 (requires option A8 against surcharge) R3
Interior socket (can only be ordered with limited temperature range - max. +70 °C). ampacity 230V/2, 2A/500W, can be switched on/off via tumbler switch in control panel, moisture tight IP68 R4
Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position left centre/centre Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position left centre/centre F0
Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position left centre top Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position left centre top F1
Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position right centre/centre Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position right centre/centre F2
Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position right centre top Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position right centre top F3
Entry port, 23 mm clear diameter for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper (please, state location) - left Entry port, 23 mm clear diameter for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper (please, state location) - left F4
Entry port, 23 mm clear diameter for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper (please, state location) - right Entry port, 23 mm clear diameter for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper (please, state location) - right F5
Entry port, 23 mm clear diameter, moisture tight, can be closed by flap and silicone stopper, in special positions (please, state location) – rear Entry port, 23 mm clear diameter, moisture tight, can be closed by flap and silicone stopper, in special positions (please, state location) – rear F6
Entry port (silicone), 40 mm clear diameter, moisture tight, can be closed by silicone stopper, at the back (please, state location; not in combination with T7, T8, T9) F7
4 – 20 mA current loop interface (-10 to +80°C corresponds to 4 to 20 mA), temperature controller, actual value V3
4 – 20 mA current loop interface (-10 to +80°C corresponds to 4 to 20 mA) Temperature of a Pt100 sensor positioned flexibly in chamber for external temperature monitoring (max. 3 TwinDISPLAY) V6
4 – 20 mA current loop interface (-10 to +80°C corresponds to 4 to 20 mA) Humidity controller, actual value (0 – 100 % rh corresponds to 4 – 20 mA) V7
Compressed air dehumidification (efficient dehumidification of the interior by means of compressed air). Standard works calibration certificate (measuring point chamber centre) at +10 °C with 10 % rh. C9
Door with lock and key (safety lock) Door with lock and key (safety lock) B6
Door hinged on the left B8
Potential-free contact for combination error message (e.g. supply failure, sensor fault, fuse) Potential-free contact for combination error message (e.g. supply failure, sensor fault, fuse) H6
Process-dependent programmable door lock (only for units with TwinDISPLAY) D4
Door-open-recognition (only for units with TwinDISPLAY) V5
MobileALERT, notification by SMS in case of any error or alarm of the device (Requires option H6) C3

Accessories

Accessories Order No.
Stainless steel grids, electropolished Stainless steel grids, electropolished E28891
Reinforced stainless steel grid, electropolished, max. loading 60 kg (model 750 with guide bars and fixing screws and only in connection with option K1) Please consider max. loading of chamber E29766
Perforated stainless steel shelves E65885
Stainless steel slide-in drip tray, 15 mm rim (may affect the temperature distribution) - cannot be used in connection with option K1 E29726
Max. loading per slide-in drip tray (kg) 4
Stainless steel bottom drip tray, 15 mm rim (may affect the temperature distribution) - cannot be used in connection with option K1 B29722
Max. loading per bottom drip tray (kg) 4
Central water supply with filter cartridges for connection to the domestic water supply. Product information on demand. ZWVR6
Central water supply without filter cartridges for connection to the domestic water supply (only for demineralised water with a conductivity of 5 to 10 μS/cm and a pH value between 5 and 7). Product information on demand ZWVR7
USB-Ethernet adapter E06192
Ethernet connection cable 5 m for computer interface E06189
USB User-ID stick (with User-ID licence): Oven-linked authorisation licence (User-ID-programme) on Memory-stick, prevents undesired manipulation by unauthorised third parties. When reordering please specify serial number (only for units with TwinDISPLAY) B33170
License for documentation software AtmoCONTROL and operating instructions for products with SingleDISPLAY. Please provide device number when reordering. B61641
Flush-fit unit (stainless steel frame covering gap between oven and wall opening), with air slots – technical clarification required Flush-fit unit (stainless steel frame covering gap between oven and wall opening), with air slots – technical clarification required B42116
Flush-fit unit (stainless steel frame covering gap between oven and wall opening), without air slots – technical clarification required Flush-fit unit (stainless steel frame covering gap between oven and wall opening), without air slots – technical clarification required B42117
Basic license for „AtmoCONTROL FDA Edition“. Meets the requirements for the use of electronically stored records and electronic signatures as specified in the 21 CFR Part 11 regulation by the US Food and Drug Administration (FDA). For devices with TwinDISPLAY only. Respective IQ/OQ documents available in German and English (at no extra charge). FDAQ1
Integration of one additional unit (up to max. 31 units) into an already existent FDA-software licence (only for units with TwinDISPLAY) FDAQ2
External measuring instrument with sensors for daylight and UV-light. Product information on demand (models HPPeco, ICHLeco/ ICHL, IPPecoplus) B04713
External measuring instrument with sensors with additional measuring head for temperature and humidity measurement. Product information on demand (models HPPeco, ICHeco/ICH, ICHLeco/ICHL, IPPecoplus and ICOmed) B04714

Services

Services Order No.
Guarantee extension by 1 year GA3Q5
Calibration at Memmert factory for a freely selectable temperature and humidity value D00105
IQ document with device-specific works test data, OQ/PQ check list as support for validation by customer D00124
IQ/OQ document with device-specific works test data, including temperature distribution survey with 9 temperature measuring points (size 30) and 27 temperature measuring points (sizes 55 - 1060) at Memmert factory for a freely selectable temperature value according to DIN12880:2007-05 (PQ check list as support for validation by customer) D00127
IQ/OQ document with device-specific works test data for one free-selectable temperature and humidity value, incl. temperature distribution survey at Memmert for 27 measuring points (26 measuring points on model HPP1400) to DIN 12880:2007-05, PQ check list as support for validation by customer (models HPP and ICH). D00136
IQ/OQ document with device-specific works test data for one free-selectable temperature and humidity value, and measuring of light intensity, incl. temperature distribution survey at Memmert for 27 measuring points to DIN 12880:2007-05, PQ check list as support for validation by customer. Price for validation at customer site on demand (GER, AT, CH only) D00137

Always ahead for you.

2026 – A year full of innovations.