Options / Accessories / Services
for Incubator Im IF450mplus
The incubator Im is a Class I medical device.
Options
| Options | Order No. | |
|---|---|---|
| Voltage 115 V, 50/60 Hz (no extra cost) | X2 | |
| Extended overtemperature protection by additionally integrated Pt100 sensor for independent temperature monitoring for models with SingleDISPLAY | A6 | |
| Temperature restriction - Temperatures: +50, +55, +60, +65, +70 or +75 °C (Please, indicate upon ordering) | A8 |
Accessories
Services
| Services | Order No. | |
|---|---|---|
| Guarantee extension by 1 year | GA2Q5 | |
| DAkkS calibration for one free-selectable temperature value according to method C (DKD-R 5-7) | E39696 | |
| Extension of DAkkS calibration at Memmert factory by an additional freely selectable temperature value according to method C (DKD-R 5-7) | E39697 | |
| IQ document with device-specific works test data, OQ/PQ check list as support for validation by customer | D00124 | |
| IQ/OQ document with device-specific works test data, including temperature distribution survey with 9 temperature measuring points (size 30) and 27 temperature measuring points (sizes 55 - 1060) at Memmert factory for a freely selectable temperature value according to DIN12880:2007-05 (PQ check list as support for validation by customer) | D00127 | |
| Extension of IQ/OQ document at Memmert factory by an additional freely selectable temperature value | D49121 | |
| Short training on the handling and use of the device on site (outside Germany price on request) | S49128 | |
| Calibration on site for a freely selectable temperature value (travel costs are not included yet) | S00205 | |
| Extension of calibration on site by an additional freely selectable temperature value | S00215 | |
| DAkkS calibration on site for a freely selectable temperature value according to method C (DKD-R 5-7) (travel costs are not included yet) | S00360 | |
| IQ/OQ qualification on site including temperature distribution survey with 9 temperature measuring points (size 30) and 27 temperature measuring points (sizes 55 - 750) for a freely selectable temperature value according to DIN12880:2007-05 (travel costs are not included yet) | DLQ100 | |
| OQ requalification on site including temperature distribution survey with 9 temperature measuring points (size 30) and 27 temperature measuring points (sizes 55 - 750) for a freely selectable temperature value according to DIN12880:2007-05 (travel costs are not included yet) | DLQ100R | |
| Extension of IQ/OQ qualification or OQ requalification on site by an additional freely selectable temperature value | DLQ100A | |
| PQ qualification on site (travel costs are not included yet) | DLQ200 | |
| Maintenance on site UIS according to Memmert maintenance plan (available on request) (travel costs are not included yet) | S00311 | |
| Maintenance contract on site UIS according to Memmert maintenance plan (available on request), minimum duration 3 years (travel costs are not included yet) | S00311J |