Options / Accessories / Services

for Paraffin oven UN55pa

For many years, and with great precision, our paraffin oven UNpa has served users in science and research in sample preparation.

Options

Options Order No.
Voltage 115 V, 50/60 Hz (no extra cost) X2
Full-sight glass door (4 insulating glass). Temperature-range up to max. 250 °C. Full-sight glass door (4 insulating glass). Temperature-range up to max. 250 °C. B0
Gas inlet/outlet through 2 tubes with ball valves - technical clarification required for combination with other options K3
Entry port, 23 mm clear diameter, for introducing connections at the side, gas tight, can be closed by flap and silicone stopper, standard position left centre/centre - technical clarification required Entry port, 23 mm clear diameter, for introducing connections at the side, gas tight, can be closed by flap and silicone stopper, standard position left centre/centre - technical clarification required F0
Entry port, 23 mm clear diameter, for introducing connections at the side, gas tight, can be closed by flap and silicone stopper, standard position left centre top - technical clarification required Entry port, 23 mm clear diameter, for introducing connections at the side, gas tight, can be closed by flap and silicone stopper, standard position left centre top - technical clarification required F1
Entry port, 23 mm clear diameter, for introducing connections at the side, gas tight, can be closed by flap and silicone stopper, standard position right centre/centre - technical clarification required Entry port, 23 mm clear diameter, for introducing connections at the side, gas tight, can be closed by flap and silicone stopper, standard position right centre/centre - technical clarification required F2
Entry port, 23 mm clear diameter, for introducing connections at the side, gas tight, can be closed by flap and silicone stopper, standard position right centre top - technical clarification required Entry port, 23 mm clear diameter, for introducing connections at the side, gas tight, can be closed by flap and silicone stopper, standard position right centre top - technical clarification required F3
Entry port, 23 mm clear diameter for introducing connections at the side, gas tight, can be closed by flap and silicone stopper, in special positions (please, state location) - left - technical clarification required Entry port, 23 mm clear diameter for introducing connections at the side, gas tight, can be closed by flap and silicone stopper, in special positions (please, state location) - left - technical clarification required F4
Entry port, 23 mm clear diameter for introducing connections at the side, gas tight, can be closed by flap and silicone stopper, in special positions (please, state location) - right - technical clarification required Entry port, 23 mm clear diameter for introducing connections at the side, gas tight, can be closed by flap and silicone stopper, in special positions (please, state location) - right - technical clarification required F5
Entry port, 23 mm clear diameter for introducing connections at the side, gas tight, can be closed by flap and silicone stopper, in special positions (please, state location) - rear - technical clarification required Entry port, 23 mm clear diameter for introducing connections at the side, gas tight, can be closed by flap and silicone stopper, in special positions (please, state location) - rear - technical clarification required F6
Entry port, 40 mm clear diameter, for introducing connections, gas tight, can be closed by flap and silicone stopper, in special positions at the back (please, state location) - technical clarification required F7
4 – 20 mA current loop interface (0 to +90°C corresponds to 4 – 20 mA), temperature controller actual value V3
4 – 20 mA current loop interface (0 to +90 °C corresponds to 4 – 20 mA), temperature of a Pt100 sensor positioned flexibly in chamber for external temperature monitoring (max. 3 TwinDISPLAY) V6
Door with lock and key (safety lock) Door with lock and key (safety lock) B6
Door hinged on the left B8
Potential-free contact for combination error message (e.g. supply failure, sensor fault, fuse) Potential-free contact for combination error message (e.g. supply failure, sensor fault, fuse) H6
Potential-free contact (24 V/2 A) with socket to NAMUR NE 28, for signal generation, controlled by programme segment, for free-selectable functions to be activated (e.g. activation of audible and visual signals, exhaust motors, fans, stirrers, etc. Only for units with TwinDISPLAY; max 2 contacts on 1-phase appliances; max 4 contacts on 3-phase appliances, 2 contacts Potential-free contact (24 V/2 A) with socket to NAMUR NE 28, for signal generation, controlled by programme segment, for free-selectable functions to be activated (e.g. activation of audible and visual signals, exhaust motors, fans, stirrers, etc. Only for units with TwinDISPLAY; max 2 contacts on 1-phase appliances; max 4 contacts on 3-phase appliances, 2 contacts H72
Process-dependent programmable door lock (only for units with TwinDISPLAY) D4
Door-open-recognition (only for units with TwinDISPLAY) V5
Flexible Pt100 temperature sensor, positioned fl exibly in chamber or load, for local temperature measurement (up to 1 additional sensor is possible). The measured temperature will be indicated on the display, recorded in the integral data store, and can be documented via the AtmoCONTROL software Flexible Pt100 temperature sensor, positioned fl exibly in chamber or load, for local temperature measurement (up to 1 additional sensor is possible). The measured temperature will be indicated on the display, recorded in the integral data store, and can be documented via the AtmoCONTROL software H8
MobileALERT, notification by SMS in case of any error or alarm of the device (Requires option H6) C3
Castor frame (2-part), height 140 mm Castor frame (2-part), height 140 mm R9

Accessories

Accessories Order No.
Stainless steel grids, electropolished Stainless steel grids, electropolished E20164
Perforated stainless steel shelf B68507
Stainless steel slide-in drip tray, 15 mm rim (may affect the temperature distribution) Stainless steel slide-in drip tray, 15 mm rim (may affect the temperature distribution) B02072
Max. loading per slide-in drip tray (kg) 1,5
Stainless steel bottom drip tray, 15 mm rim (may affect the temperature distribution) Stainless steel bottom drip tray, 15 mm rim (may affect the temperature distribution) B04358
Max. loading per bottom drip tray (kg) 1,5
Wall bracket for wall mounting Wall bracket for wall mounting B29756
USB-Ethernet adapter E06192
Ethernet connection cable 5 m for computer interface E06189
USB User-ID stick (with User-ID licence): Oven-linked authorisation licence (User-ID-programme) on Memory-stick, prevents undesired manipulation by unauthorised third parties. When reordering please specify serial number (only for units with TwinDISPLAY) B33170
Set of height adjustable feet (4 pcs) B29768
Stacking set (4 pcs) for stacking of appliances of same size Stacking set (4 pcs) for stacking of appliances of same size B29744
Flush-fit unit (stainless steel frame covering gap between oven and wall opening), with air slots – technical clarification required Flush-fit unit (stainless steel frame covering gap between oven and wall opening), with air slots – technical clarification required B29730
Flush-fit unit (stainless steel frame covering gap between oven and wall opening), without air slots – technical clarification required Flush-fit unit (stainless steel frame covering gap between oven and wall opening), without air slots – technical clarification required B29731
Subframe, adjustable in height (size 30 to 75: height 600 mm, size 110 to 450: height 500 mm) Subframe, adjustable in height (size 30 to 75: height 600 mm, size 110 to 450: height 500 mm) B29747
Subframe, on castors (size 30 to 75: height 660 mm, size 110 to 160: height 560 mm) Subframe, on castors (size 30 to 75: height 660 mm, size 110 to 160: height 560 mm) B29748
Subframe, adjustable in height, height 130 mm B33659
Basic licence for AtmoCONTROL FDA and myChamber Control FDA. Meets the requirements for the use of electronically stored records and electronic signatures as set out in 21 CFR Part 11 of the US Food and Drug Administration (FDA). A volume discount is granted for the purchase of multiple licences per order. 10% for a minimum of 5 licences / 20% for a minimum of 10 licences / 30% for 20 or more licences FDAQ1

Services

Services Order No.
Guarantee extension by 1 year GA1Q5
Calibration at Memmert factory for a freely selectable temperature value D00109
Calibration at Memmert factory for three temperature values: +37, +52, +70 °C D00126
DAkkS calibration for one free-selectable temperature value according to method C (DKD-R 5-7) E39696
Extension of DAkkS calibration at Memmert factory by an additional freely selectable temperature value according to method C (DKD-R 5-7) E39697
IQ document with device-specific works test data, OQ/PQ check list as support for validation by customer D00124
IQ/OQ document with device-specific works test data, including temperature distribution survey with 9 temperature measuring points (size 30) and 27 temperature measuring points (sizes 55 - 1060) at Memmert factory for a freely selectable temperature value according to DIN12880:2007-05 (PQ check list as support for validation by customer) D00127
Extension of IQ/OQ document at Memmert factory by an additional freely selectable temperature value D49121
Short training on the handling and use of the device on site (outside Germany price on request) S49128
Calibration on site for a freely selectable temperature value (travel costs are not included yet) S00205
Extension of calibration on site by an additional freely selectable temperature value S00215
DAkkS calibration on site for a freely selectable temperature value according to method C (DKD-R 5-7) (travel costs are not included yet) S00360
IQ/OQ qualification on site including temperature distribution survey with 9 temperature measuring points (size 30) and 27 temperature measuring points (sizes 55 - 160) for a freely selectable temperature value according to DIN12880:2007-05 (travel costs are not included yet) DLQ100
OQ requalification on site including temperature distribution survey with 9 temperature measuring points (size 30) and 27 temperature measuring points (sizes 55 - 160) for a freely selectable temperature value according to DIN12880:2007-05 (travel costs are not included yet) DLQ100R
Extension of IQ/OQ qualification or OQ requalification on site by an additional freely selectable temperature value DLQ100A
PQ qualification on site (travel costs are not included yet) DLQ200
Maintenance on site UIS according to Memmert maintenance plan (available on request) (travel costs are not included yet) S00311
Maintenance contract on site UIS according to Memmert maintenance plan (available on request), minimum duration 3 years (travel costs are not included yet) S00311J

Always ahead for you.

2026 – A year full of innovations.