Options / Accessories / Services

for Universal oven

Precise drying, heating, ageing, burn-in and hardening in research, science, industry and quality assurance.

Options

Model sizes 30 55 75 110 160 260 450 750 1060
Voltage 115 V, 50/60 Hz (no extra cost) X2 X2 X2 X2 X2 X2
Extended overtemperature protection by additionally integrated Pt100 sensor for independent temperature monitoring for models with SingleDISPLAY A6 A6 A6 A6 A6 A6 A6 A6 A6
Temperature restriction - Temperatures: +60, +70, +80, +95, +100, +120, +160, +180, +200 or +250 °C (Please, indicate upon ordering) A8 A8 A8 A8 A8 A8 A8 A8 A8
Full-sight glass door (4-layer insulating glass), temperature range up to max. +250 °C (requires option A8 against surcharge) Full-sight glass door (4-layer insulating glass), temperature range up to max. +250 °C (requires option A8 against surcharge) B0 B0 B0 B0 B0 B0 B0 B0 B0
Full-sight glass door (4 insulating glass). Temperature-range up to max. 300 °C. Full-sight glass door (4 insulating glass). Temperature-range up to max. 300 °C. B1 B1 B1 B1 B1 B1 B1 B1 B1
Chamber modification for the application of reinforced perforated stainless steel shelves or stainless steel grids (bearing rails mounted in the working chamber) - includes replacement of standard grids by reinforced grids (standard with 1060) K1 K1
Interior lighting for observing the load Interior lighting for observing the load R0 R0 R0 R0 R0 R0 R0 R0 R0
Interior socket (can only be ordered with limited temperature range - max. +60 °C), ampacity 230V/2, 2A/500W, can be switched off with the On/Off switch, cannot be switched individually, moisture tight IP68 (requires option A8 against surcharge) R3 R3 R3 R3 R3 R3 R3 R3 R3
Interior nearly gastight - technical clarification required for combination with other options K2 K2 K2 K2 K2 K2 K2 K2 K2
Interior nearly gastight with possibility for inlet/outlet through 2 tubes with ball valves - technical clarification required for combination with other options K3 K3 K3 K3 K3 K3 K3 K3 K3
Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position left centre/centre Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position left centre/centre F0 F0 F0 F0 F0 F0 F0 F0 F0
Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position left centre top Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position left centre top F1 F1 F1 F1 F1 F1 F1 F1 F1
Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position right centre/centre Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position right centre/centre F2 F2 F2 F2 F2 F2 F2 F2 F2
Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position right centre top Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position right centre top F3 F3 F3 F3 F3 F3 F3 F3 F3
Entry port, 23 mm clear diameter for introducing connections at the side, can be closed by flap in special positions (please, state location) - left Entry port, 23 mm clear diameter for introducing connections at the side, can be closed by flap in special positions (please, state location) - left F4 F4 F4 F4 F4 F4 F4 F4 F4
Entry port, 23 mm clear diameter for introducing connections at the side, can be closed by flap in special positions (please, state location) - right Entry port, 23 mm clear diameter for introducing connections at the side, can be closed by flap in special positions (please, state location) - right F5 F5 F5 F5 F5 F5 F5 F5 F5
Entry port, 23 mm clear diameter for introducing connections, can be closed by flap in special positions (please, state location) - rear Entry port, 23 mm clear diameter for introducing connections, can be closed by flap in special positions (please, state location) - rear F6 F6 F6 F6 F6 F6 F6 F6 F6
Entry port, 14 mm clear diameter, can be closed by flap, in special positions at the back (please, state location) Entry port, 14 mm clear diameter, can be closed by flap, in special positions at the back (please, state location) D6 D6 D6 D6 D6 D6 D6 D6 D6
Entry port, 38 mm clear diameter, can be closed by flap, in special positions at the back (please, state location) Entry port, 38 mm clear diameter, can be closed by flap, in special positions at the back (please, state location) F7 F7 F7 F7 F7 F7 F7 F7 F7
Entry port, 57 mm clear diameter, can be closed by flap, in special positions at the back (please, state location; not possible for UF/UFplus/UFm/UFmplus size 30-75) Entry port, 57 mm clear diameter, can be closed by flap, in special positions at the back (please, state location; not possible for UF/UFplus/UFm/UFmplus size 30-75) F8 F8 F8 F8 F8 F8 F8 F8 F8
Entry port, 100 mm clear diameter, can be closed by flap, in special positions at the back (please, state location; not possible for UF/UFplus/UFm/UFmplus size 75) Entry port, 100 mm clear diameter, can be closed by flap, in special positions at the back (please, state location; not possible for UF/UFplus/UFm/UFmplus size 75) F9 F9 F9 F9 F9 F9 F9
4 – 20 mA current loop interface (0 to +310°C corresponds to 4 – 20 mA), temperature controller actual value V3 V3 V3 V3 V3 V3 V3 V3 V3
4 – 20 mA current loop interface (0 to +310 °C corresponds to 4 – 20 mA), temperature of a Pt100 sensor positioned flexibly in chamber for external temperature monitoring (max. 1 SingleDISPLAY, max. 3 TwinDISPLAY) V6 V6 V6 V6 V6 V6 V6 V6 V6
Fan speed monitoring with switching off the heating and with alarm in case of failure – optional for UFplus only V4 V4 V4 V4 V4 V4 V4 V4 V4
Door with lock and key (safety lock) Door with lock and key (safety lock) B6 B6 B6 B6 B6 B6 B6 B6 B6
Door hinged on the left B8 B8 B8 B8 B8 B8
Potential-free contact for combination error message (e.g. supply failure, sensor fault, fuse) Potential-free contact for combination error message (e.g. supply failure, sensor fault, fuse) H6 H6 H6 H6 H6 H6 H6 H6 H6
Potential-free contact (24 V/2 A) with socket to NAMUR NE 28, for signal generation, controlled by programme segment, for free-selectable functions to be activated (e.g. activation of audible and visual signals, exhaust motors, fans, stirrers, etc. Only for units with TwinDISPLAY; max 2 contacts on 1-phase appliances; max 4 contacts on 3-phase appliances, 2 contacts Potential-free contact (24 V/2 A) with socket to NAMUR NE 28, for signal generation, controlled by programme segment, for free-selectable functions to be activated (e.g. activation of audible and visual signals, exhaust motors, fans, stirrers, etc. Only for units with TwinDISPLAY; max 2 contacts on 1-phase appliances; max 4 contacts on 3-phase appliances, 2 contacts H72 H72 H72 H72 H72 H72 H72 H72 H72
Process-dependent programmable door lock (only for units with TwinDISPLAY) D4 D4 D4 D4 D4 D4 D4 D4 D4
Door-open-recognition (only for units with TwinDISPLAY) V5 V5 V5 V5 V5 V5 V5 V5 V5
Flexible Pt100 temperature sensor, positioned fl exibly in chamber or load, for local temperature measurement (up to 1 additional sensor is possible). The measured temperature will be indicated on the display, recorded in the integral data store, and can be documented via the AtmoCONTROL software Flexible Pt100 temperature sensor, positioned fl exibly in chamber or load, for local temperature measurement (up to 1 additional sensor is possible). The measured temperature will be indicated on the display, recorded in the integral data store, and can be documented via the AtmoCONTROL software H8 H8 H8 H8 H8 H8 H8 H8 H8
MobileALERT, notification by SMS in case of any error or alarm of the device (Requires option H6) C3 C3 C3 C3 C3 C3 C3 C3 C3
Castor frame (2-part), height 140 mm Castor frame (2-part), height 140 mm R9 R9 R9 R9 R9 R9
Fresh-air filter (filtration efficiency 80 %) mounted at the bottom (for UF/UFplus). For model sizes 30 – 260, subframe or subframe on castors obligatory Fresh-air filter (filtration efficiency 80 %) mounted at the bottom (for UF/UFplus). For model sizes 30 – 260, subframe or subframe on castors obligatory R8 R8 R8 R8 R8 R8 R8 R8 R8

Accessories

Model sizes 30 55 75 110 160 260 450 750 1060
Stainless steel grids, electropolished Stainless steel grids, electropolished E28884 E20164 E20164 E20165 E20165 E28891 E20182 E20182 B41251
Reinforced stainless steel grid, electropolished, max. loading 60 kg; from size 450 with guide bars and fixing screws (only in connection with option K1). Please consider max. loading of chamber E29767 E29767 E29766 B32190 B32190 B32550
Perforated stainless steel shelf B68506 B68507 B68507 B68508 B68508 B68510 B68518 B68518
Reinforced perforated stainless steel shelves, max. loading 60 kg, with guide bars and fixing screws and only in connection with option K1. Please consider max. loading of chamber B68521 B68521 B68523
Stainless steel slide-in drip tray, 15 mm rim (may affect the temperature distribution) - cannot be used in connection with option K1 B02070 B02072 B02072 B02073 B02073 B29726 B02075 B02075 B32599
Stainless steel slide-in drip tray, 15 mm rim, with guide bars and fixing screws (may affect the temperature distribution) - can be used only in connection with option K1 B32763 B32763
Max. loading per slide-in drip tray (kg) 1,5 1,5 1,5 3 3 4 8 8 8
Stainless steel bottom drip tray, 15 mm rim (may affect the temperature distribution) - cannot be used in connection with option K1 B04356 B04358 B04358 B04359 B04359 B29722 B04362 B04362 B29769
Stainless steel bottom drip tray, 15 mm rim (may affect the temperature distribution) - can be used only in connection with option K1 B34055 B34055
Max. loading per bottom drip tray (kg) 1,5 1,5 1,5 3 3 4 8 8 8
Wall bracket for wall mounting Wall bracket for wall mounting B29755 B29756 B29757 B29758 B29759
USB-Ethernet adapter E06192 E06192 E06192 E06192 E06192 E06192 E06192 E06192 E06192
Ethernet connection cable 5 m for computer interface E06189 E06189 E06189 E06189 E06189 E06189 E06189 E06189 E06189
USB User-ID stick (with User-ID licence): Oven-linked authorisation licence (User-ID-programme) on Memory-stick, prevents undesired manipulation by unauthorised third parties. When reordering please specify serial number (only for units with TwinDISPLAY) B33170 B33170 B33170 B33170 B33170 B33170 B33170 B33170 B33170
License for documentation software AtmoCONTROL and operating instructions for products with SingleDISPLAY. Please provide device number when reordering. B61641 B61641 B61641 B61641 B61641 B61641 B61641 B61641 B61641
Set of height adjustable feet (4 pcs) B29768 B29768 B29768 B29768 B29768 B29768
Stacking set (4 pcs) for stacking of appliances of same size Stacking set (4 pcs) for stacking of appliances of same size B29744 B29744 B29744 B29744
Plug-in tube extension (outer diam. 60,3 mm, inner 57 mm), straight, for exhaust air ducting (if necessary for connection by hose) Plug-in tube extension (outer diam. 60,3 mm, inner 57 mm), straight, for exhaust air ducting (if necessary for connection by hose) B29718 B29718 B29718 B29718 B29718 B29718 B29718 B29718 B29718
Plug-in tube extension (outer diam. 60,3 mm, inner 57 mm), angled, for exhaust air ducting (if necessary for connection by hose), only models U, I, S Plug-in tube extension (outer diam. 60,3 mm, inner 57 mm), angled, for exhaust air ducting (if necessary for connection by hose), only models U, I, S B29719 B29719 B29719 B29719 B29719 B29719 B29719 B29719 B29719
Flush-fit unit (stainless steel frame covering gap between oven and wall opening), with air slots – technical clarification required Flush-fit unit (stainless steel frame covering gap between oven and wall opening), with air slots – technical clarification required B29728 B29730 B29732 B29734 B29736 B29738 B29740 B29742 B29742
Flush-fit unit (stainless steel frame covering gap between oven and wall opening), without air slots – technical clarification required Flush-fit unit (stainless steel frame covering gap between oven and wall opening), without air slots – technical clarification required B29729 B29731 B29733 B29735 B29737 B29739 B29741 B29743 B29743
Subframe, adjustable in height (size 30 to 75: height 600 mm, size 110 to 450: height 500 mm) Subframe, adjustable in height (size 30 to 75: height 600 mm, size 110 to 450: height 500 mm) B29745 B29747 B29747 B29749 B29749 B29751 B29753
Subframe, on castors (size 30 to 75: height 660 mm, size 110 to 160: height 560 mm) Subframe, on castors (size 30 to 75: height 660 mm, size 110 to 160: height 560 mm) B29746 B29748 B29748 B29750 B29750
Subframe, adjustable in height, height 130 mm B33657 B33659 B33659 B33661 B33661 B33664
Basic licence for AtmoCONTROL FDA and myChamber Control FDA. Meets the requirements for the use of electronically stored records and electronic signatures as set out in 21 CFR Part 11 of the US Food and Drug Administration (FDA). A volume discount is granted for the purchase of multiple licences per order. 10% for a minimum of 5 licences / 20% for a minimum of 10 licences / 30% for 20 or more licences FDAQ1 FDAQ1 FDAQ1 FDAQ1 FDAQ1 FDAQ1 FDAQ1 FDAQ1 FDAQ1

Services

Model sizes 30 55 75 110 160 260 450 750 1060
Guarantee extension by 1 year GA1Q5 GA1Q5 GA1Q5 GA1Q5 GA1Q5 GA2Q5 GA2Q5 GA2Q5 GA2Q5
Calibration at Memmert factory for a freely selectable temperature value D00109 D00109 D00109 D00109 D00109 D00109 D00109 D00109 D00109
Calibration at Memmert factory for three temperature values: +100, +160, +220 °C Calibration at Memmert factory for three temperature values: +100, +160, +220 °C D00128 D00128 D00128 D00128 D00128 D00128 D00128 D00128 D00128
DAkkS calibration for one free-selectable temperature value according to method C (DKD-R 5-7) E39696 E39696 E39696 E39696 E39696 E39696 E39696 E39696 E39696
Extension of DAkkS calibration at Memmert factory by an additional freely selectable temperature value according to method C (DKD-R 5-7) E39697 E39697 E39697 E39697 E39697 E39697 E39697 E39697 E39697
IQ document with device-specific works test data, OQ/PQ check list as support for validation by customer D00124 D00124 D00124 D00124 D00124 D00124 D00124 D00124 D00124
IQ/OQ document with device-specific works test data, including temperature distribution survey with 9 temperature measuring points (size 30) and 27 temperature measuring points (sizes 55 - 1060) at Memmert factory for a freely selectable temperature value according to DIN12880:2007-05 (PQ check list as support for validation by customer) D00125 D00127 D00127 D00127 D00127 D00127 D00127 D00127 D00127
Extension of IQ/OQ document at Memmert factory by an additional freely selectable temperature value D49121 D49121 D49121 D49121 D49121 D49121 D49121 D49121 D49121
Short training on the handling and use of the device on site (outside Germany price on request) S49128 S49128 S49128 S49128 S49128 S49128 S49128 S49128 S49128
Calibration on site for a freely selectable temperature value (travel costs are not included yet) S00205 S00205 S00205 S00205 S00205 S00205 S00205 S00205 S00205
Extension of calibration on site by an additional freely selectable temperature value S00215 S00215 S00215 S00215 S00215 S00215 S00215 S00215 S00215
DAkkS calibration on site for a freely selectable temperature value according to method C (DKD-R 5-7) (travel costs are not included yet) S00360 S00360 S00360 S00360 S00360 S00360 S00360 S00360 S00360
IQ/OQ qualification on site including temperature distribution survey with 9 temperature measuring points (size 30) and 27 temperature measuring points (sizes 55 - 1060) for a freely selectable temperature value according to DIN12880:2007-05 (travel costs are not included yet) DLQ100 DLQ100 DLQ100 DLQ100 DLQ100 DLQ100 DLQ100 DLQ100 DLQ100
OQ requalification on site including temperature distribution survey with 9 temperature measuring points (size 30) and 27 temperature measuring points (sizes 55 - 1060) for a freely selectable temperature value according to DIN12880:2007-05 (travel costs are not included yet) DLQ100R DLQ100R DLQ100R DLQ100R DLQ100R DLQ100R DLQ100R DLQ100R DLQ100R
Extension of IQ/OQ qualification or OQ requalification on site by an additional freely selectable temperature value DLQ100A DLQ100A DLQ100A DLQ100A DLQ100A DLQ100A DLQ100A DLQ100A DLQ100A
PQ qualification on site (travel costs are not included yet) DLQ200 DLQ200 DLQ200 DLQ200 DLQ200 DLQ200 DLQ200 DLQ200 DLQ200
Maintenance on site UIS according to Memmert maintenance plan (available on request) (travel costs are not included yet) S00311 S00311 S00311 S00311 S00311 S00311 S00311 S00311 S00311
Maintenance contract on site UIS according to Memmert maintenance plan (available on request), minimum duration 3 years (travel costs are not included yet) S00311J S00311J S00311J S00311J S00311J S00311J S00311J S00311J S00311J