Options / Accessories / Services

for Water bath WTB11

Ideal for the temperature control of ointments, emulsions, samples, plates and nutrient solutions in the laboratory, as well as warm storage and calibration in the industrial segment

Options

Options Order No.
Voltage 115 V, 50/60 Hz (no extra cost) X2

Accessories

Accessories Order No.
Stainless steel gable cover Stainless steel gable cover B50775
Flat stainless steel cover with openings and concentric ring sets; 3 openings, Ø 87 mm Flat stainless steel cover with openings and concentric ring sets; 3 openings, Ø 87 mm B48804
Special flat stainless steel cover with openings and concentric ring sets; 3 openings, Ø 87 mm (only in combination with CPM650) Special flat stainless steel cover with openings and concentric ring sets; 3 openings, Ø 87 mm (only in combination with CPM650) B48807
Perforated bottom shelf, reversible for 2 heights (30 or 60 mm), stainless steel Perforated bottom shelf, reversible for 2 heights (30 or 60 mm), stainless steel B50767
Pump device for continuous circulation of the tempering medium. Voltage 230 V, 50/60 Hz. Please do not forget to order the installation and connection set (B48813)! Pump device for continuous circulation of the tempering medium. Voltage 230 V, 50/60 Hz. Please do not forget to order the installation and connection set (B48813)! CPM650
Installation and connection set for pump device CPM650 (incl. mounting bars for all different bath sizes) B48813
Test tube racks, holes 2-row racks, 34 holes, Ø 10 mm each (bath capacity 3 racks) Test tube racks, holes 2-row racks, 34 holes, Ø 10 mm each (bath capacity 3 racks) B48822
Test tube racks, holes 2-row racks, 30 holes, Ø 12 mm each (bath capacity 3 racks) Test tube racks, holes 2-row racks, 30 holes, Ø 12 mm each (bath capacity 3 racks) B48824
Test tube racks, holes 2-row racks, 26 holes, Ø 14.5 mm each (bath capacity 2 racks) Test tube racks, holes 2-row racks, 26 holes, Ø 14.5 mm each (bath capacity 2 racks) B48826
Test tube racks, holes 2-row racks, 22 holes, Ø 18 mm each (bath capacity 2 racks) Test tube racks, holes 2-row racks, 22 holes, Ø 18 mm each (bath capacity 2 racks) B48828
Test tube racks, holes 2-row racks, 18 holes, Ø 21 mm each (bath capacity 2 racks) Test tube racks, holes 2-row racks, 18 holes, Ø 21 mm each (bath capacity 2 racks) B48830
Test tube racks, holes 2-row racks, 14 holes, Ø 32 mm each (bath capacity 1 rack) Test tube racks, holes 2-row racks, 14 holes, Ø 32 mm each (bath capacity 1 rack) B48832
Test tube racks, holes 3- row racks, 33 holes, Ø 18 mm each (bath capacity 1 rack) Test tube racks, holes 3- row racks, 33 holes, Ø 18 mm each (bath capacity 1 rack) B48834
Test tube racks, holes 4-row racks, 44 holes, Ø 18 mm each (bath capacity 1 rack) Test tube racks, holes 4-row racks, 44 holes, Ø 18 mm each (bath capacity 1 rack) B48836

Services

Services Order No.
Calibration at Memmert factory for a freely selectable temperature value D00109
Calibration at Memmert factory for a temperature value: +37 °C D00123
IQ/OQ document with device-specific works test data, including temperature distribution survey with 9 temperature measuring points at Memmert factory for a freely selectable temperature value according to DIN12880:2007-05 (PQ check list as support for validation by customer) D00125
Extension of IQ/OQ document at Memmert factory by an additional freely selectable temperature value D49121
Short training on the handling and use of the device on site (outside Germany price on request) S49128
Calibration on site for a freely selectable temperature value (travel costs are not included yet) S00205
Extension of calibration on site by an additional freely selectable temperature value S00215
Maintenance on site WTB according to Memmert maintenance plan (available on request) (travel costs are not included yet) S00321
Maintenance contract on site WTB according to Memmert maintenance plan (available on request), minimum duration 3 years (travel costs are not included yet) S00321J