On this page, you can find all the essential technical data on the Memmert ICO CO2 Incubator. Our customer relations team will be pleased to help if you want further information. If you should require a customised special solution, please contact our technical specialists at [email protected].
Range of functions
| Calibrate | Three freely selectable values: temperature, humidity, and CO2 |
|---|---|
| Timer | Timer - Process time starts immediately when the programme starts; Timer SetpointWAIT - Process time only starts after all setpoint values have been reached; Timer on Event - Process time starts at a defined point in time |
| Language settings | English (default), German, French, Spanish, Portuguese, Chinese, Arabic, Hindi, Polish, Czech, Hungarian, Russian, Italian, Serbian |
| Appliance functions | Date and time (time zones, summer/winter time); Display brightness; DistanceView (1–4 freely selectable parameters, activation time adjustable); Network settings (IP, subnet, DHCP); Language and volume settings (buzzer/key tone); Power failure behaviour; Timer functions |
| Adjustable parameters | Temperature; CO2; Relative humidity (requires option K7); O2 (requires option T6) |
| Control unit | 6.86" IPS touch display (480 × 1280 pixels) with multi-touch function for graphical display of actual/setpoint values and parameter curves. |
O2 (only with T6 option)
| Control system | Anaerobic O2 control for targeted oxygen reduction via nitrogen inlet. Zirconium oxide sensor with integrated monitoring and error display. Filtered N₂ supply for safe process conditions. |
|---|---|
| Adjustment precision | 0,1 % |
| O2 - Setting range | 1 to 20 % |
Seguridad
| Power failure | Manual mode: Power failure less than 24 hours: Active process is terminated, parameters remain stored. Power failure longer than 24 hours: Operation continues with previously set parameters. Program mode (power failure >1 hour): Failure less than 1 hour: Programme continues with remaining runtime. Failure longer than 1 hour: Programme is stopped; query for continuation required |
|---|---|
| Temperature monitoring | Dual Pt1000 sensor, DIN Class A, for mutual monitoring and automatic takeover in the event of a fault |
| Alarma | óptica y acústica |
Interior de acero inoxidable
| Dimensions | w(A) x h(B) x d(C): 400 x 425 x 330 mm |
|---|---|
| Volumen | 56 l |
| N° máx. de inserciones | 4 |
| Máx. carga de la cámara del equipo: | 50 kg |
| Carga máx. por inserción | 15 kg |
Datos eléctricos
| Voltaje consumo eléctrico | 230 V, 50/60 Hz aprox. 1200 W |
|---|---|
| Voltaje consumo eléctrico | 115 V, 50/60 Hz aprox. 1200 W |
Condiciones ambientales
| Instalación | La separación entre la pared y la parte posterior del equipo deberá ser como mínimo de 15 cm. La distancia hasta el techo debe ser como mínimo de 20 cm y la distancia de los laterales a la pared o al equipo contiguo de al menos 5 cm. |
|---|---|
| Temperatura ambiente | 10 °C a 35 °C |
| Altura de instalación | Máx. 2000 m sobre el nivel del mar |
| Categoría de sobretensión | II |
| Grado de contaminación | 2 |
Datos de embalaje/envío
| Información de transporte | ¡Los equipos deben transportarse en posición vertical! |
|---|---|
| Número estadístico de mercancía | 8419 8998 |
| País de origen | República Federal de Alemania |
| N.° Reg. WEEE | DE 66812464 |
| Medidas aprox. incl. cartón | An x Al x F 655 x 893 x 755 mm |
| Peso neto | aprox. 53 kg |
| Peso bruto cartón | aprox. 66 kg |
Temperature
| Temperature control system | Large-area multi-zone multifunctional all-round heating with additional door, seal and rear wall heating |
|---|---|
| Setting temperature range | +20 to +50 °C |
| Rango de temperatura de trabajo | 5 sobre la temperatura ambiente a +50 programa de esterilización incluido, 60 minutos a 180 °C – sin la eliminación de los sensores |
| Resolución del indicador valores nominales de la temperatura y valores reales | 0,1 °C |
| Uniformidad espacial de temperatura | a + 37 °C +/- 0.3 K |
| Estabilidad temporal de temperatura | a +37 °C +/- 0.1 K |
Humidity
| Humidification system | Passive humidification by means of integrated water tank with condensate return via magnetically guided sealing lip. Humidity limitation by Peltier element. Active closed-loop humidity control (option K7) with capacitive sensor for precise measurement and complete documentation. Humidification via self-priming micro-dosing pump with hot steam generation, dehumidification via powerful diaphragm pump. |
|---|---|
| Accuracy | 0,1% rh |
| Setting range | 40 to 98 and rh-Off |
CO2
| Control system | Precise CO2 control with dual-beam NDIR technology, integrated monitoring and pressure-compensated measurement. Filtered CO2 supply for high process reliability. |
|---|---|
| Temporal fluctuation | ± 0,2 % |
| Setting range | 0 to 20 % |
Communication
| Interfaces | USB-C; Ethernet LAN |
|---|
Standard equipment
| Standard option | Door-open detection | V5 |
|---|---|
| Factory calibration certificate III (Option T6) | +37 °C, 5 %CO2, 90 %RH, 10 %O2 |
| Factory calibration certificate II (Option K7) | +37 °C, 5 %CO2, 90 %RH |
| Factory calibration certificate I (Standard) | +37 °C, 5 %CO2 |
| Additional accessories | CO2 connection set, hose with connection coupling and hose clamp; Water dish (Basic equipment); Water tank including connection hose (requires Option K7); Preset sterilisation programme: 60 minutes at +180 °C (without removing the sensors) |
| Puerta | Puerta de acero inoxidable completamente aislada con dos puntos de cierre (cerradura de la puerta con compresión) |
| Puerta | puerta de cristal interior con orificio (8 mm de Ø) para el muestreo de gas |
| Inserciones | 1 bandeja(s) perforada(s) de acero inoxidable |
Textured stainless steel casing
| Medidas | w(D) x h(E) x d(F): 548 x 628 x 519 mm |
|---|---|
| Installation | 4 adjustable appliance feet |
Las unidades estándar están aprobadas en materia de seguridad y llevan las marcas certificadoras